Terminal Descriptions
TERMINAL | GROUP | FUNCTION | |
|
|
| |
AC N | 24 VOLT INPUT | FACTORY CONNECTED TO 24 VAC FROM TRANSFORMER OR | |
AC | 24 VDC FROM CONTINUOUS DUTY DC SUPPLY. | ||
| |||
DC - | ACCESSORY POWER | PROVIDES 24 VOLT DC POWER FOR ACCESSORIES. (.5A MAX) | |
DC + | |||
|
| ||
RESET | RESET BUTTON | FACTORY CONNECTED TO THE CONTROLLER’S RESET BUTTON. | |
COMMON | |||
|
| ||
C |
|
| |
B | COMM LINK | FOR | |
A |
|
| |
COMMON | SINGLE BUTTON INPUT | CONNECT TO NORMALLY OPEN SWITCH FOR SINGLE BUTTON OPERATION. ALTERNATES | |
SINGLE | BETWEEN | ||
| |||
COMMON | FIRE BOX INPUT | CONNECT TO NORMALLY OPEN SWITCH IN FIRE BOX FOR FIRE DEPARTMENT ACCESS. | |
FIRE DEPT | |||
|
| ||
COMMON |
| CONNECT TO NORMALLY OPEN DEVICES (KEYPAD, CARD READER, KEYSWITCH, | |
OPEN | OPEN INPUT | TELEPHONE ENTRY SYSTEM) TO OPEN THE GATE. A CONSTANT OPEN INPUT WILL | |
| OVERRIDE THE | ||
|
| ||
OPEN |
|
| |
CLOSE | CONNECT TO | ||
COMMON | STATION INPUT | WILL OVERRIDE THE | |
STOP |
|
| |
COM |
| CONNECT TO NORMALLY OPEN DEVICES (GATE EDGE, PHOTO BEAM) TO DETECT AN | |
| OBSTRUCTION DURING OPENING. WHILE GATE IS MOVING, ANY OPEN OBSTRUCTION | ||
| OPEN | SIGNAL WILL CAUSE THE GATE TO STOP, REVERSE A SHORT DISTANCE, AND THEN STOP | |
| OBSTRUCTION | AGAIN. AT THIS TIME THE AUTO CLOSE TIMER IS DISABLED, AND A RENEWED INPUT | |
| |||
| INPUT | WILL BE REQUIRED TO START THE GATE AGAIN. SHOULD THE GATE BE RESTARTED | |
| AND THE OBSTACLE SIGNAL OCCUR AGAIN PRIOR TO REACHING A LIMIT, THE GATE | ||
|
| WILL STOP AGAIN, LOCKOUT, AND SOUND THE CONTINUOUS TONE ALARM. | |
|
|
| |
|
| CONNECT TO NORMALLY OPEN DEVICES (GATE EDGE, PHOTO BEAM) TO DETECT AN | |
| OBSTRUCTION DURING CLOSING. WHILE GATE IS MOVING, ANY CLOSE OBSTRUCTION | ||
| CLOSE | SIGNAL WILL CAUSE THE GATE TO STOP, THEN REVERSE AND TRAVEL TO THE FULL | |
| OPEN POSITION. SHOULD A OPEN OBSTRUCTION INPUT OR AN OPEN DIRECTION | ||
| OBSTRUCTION | ||
| INHERENT ENTRAPMENT CONDITION OCCUR PRIOR TO THE GATE REACHING THE | ||
| INPUT | ||
| OPEN LIMIT, THE OPERATOR WILL LOCKOUT AND SOUND THE CONTINUOUS TONE | ||
COM |
| ||
| ALARM. IF THE AUTO CLOSE TIMER IS SET, WHEN THE CLOSE OBSTRUCTION INPUT | ||
|
| IS CLEARED, THE GATE WILL CLOSE WHEN THE AUTO CLOSE TIMER EXPIRES. | |
|
|
| |
COM | REVERSE | CONNECT TO NORMALLY OPEN DEVICES TO CAUSE A REVERSAL WHEN THE GATE IS | |
REV | TRAVELING CLOSED. THE GATE WILL REVERSE TO THE FULL OPEN POSITION. | ||
| |||
OPEN LOOP |
| CONNECT TO OPEN LOOP/FREE EXIT LOOP. THE GATE WILL OPEN | |
OPEN LOOP | OPEN LOOP | WHEN THE LOOP IS TRIGGERED, AND REMAIN OPEN AS LONG AS | |
| THE LOOP IS TRIGGERED. REQUIRES LOOP DETECTOR. | ||
|
| ||
REVERSE LOOP |
| CONNECT TO REVERSE LOOP. TRIGGERING THE LOOP WILL CAUSE A | |
REVERSE LOOP | REVERSE LOOP | REVERSAL WHEN THE GATE IS TRAVELING CLOSED. THE GATE WILL REVERSE | |
| TO THE FULL OPEN POSITION. REQUIRES LOOP DETECTOR. | ||
|
| ||
SHADOW/RESET LOOP |
| CONNECT TO SHADOW/RESET LOOP TO KEEP THE GATE IN ITS FULLY OPEN | |
SHADOW/RESET LOOP | SHADOW/RESET LOOP | POSITION AS LONG AS THE SIGNAL IS PRESENT. USED TO KEEP GATE OPEN | |
| WHILE VEHICLE IS PASSING THROUGH. REQUIRES LOOP DETECTOR. | ||
|
| ||
- | ALARM | FACTORY CONNECTED TO THE ALARM BEEPER. | |
+ | |||
|
| ||
N.O. |
| FOR CONNECTION TO AUXILIARY DEVICES (MAGNETIC LOCK, SOLENOID LOCK, | |
COM | AUX RELAY | ||
STROBE LIGHT) FOR ACTIVATION (OR DEACTIVATION) DURING GATE OPERATION. | |||
N.C. |
| ||
|
| ||
+ | 24 VOLT SOLAR PANEL | NOT USED WITH THIS MODEL OPERATOR. | |
- | |||
|
| ||
+ | 24 VOLT BATTERY | NOT USED WITH THIS MODEL OPERATOR. | |
- | |||
|
|
- 10 - | P1250 Revision X6 | |
|