Linear VS-GSWG manual Run Alarm and Pre-start Alarm, Maximum Open Direction Current Setting

Page 15

Basic Controller Programming (Cont.)

Run Alarm and Pre-start Alarm

The factory default is Run Alarm on and a 3-second Pre-start Alarm. The operator’s beeper will sound 3 seconds before the operator starts. The options are:

Run Alarm Off and Pre-start Alarm Off

Run Alarm On and Pre-start Alarm Off

Run Alarm On and Pre-start Alarm On for 1-9 Seconds

FUNCTION

"RP"

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO SELECT AN OPTION

OPTIONS

RUN ALARM OFF

PRE-START ALARM OFF

RUN ALARM ON

PRE-START ALARM OFF

RUN ALARM ON

PRE-START ALARM ON FOR 1 - 9 SECONDS

Maximum Open Direction Current Setting

To detect obstacles or mechanical problems with the gate, the operator monitors its motor current. If the open current load exceeds the programmed maximum load range number, the operator will stop, reverse

RUN ALARM

PRE-START ALARM

a short distance, then stop again. The Auto Close Timer will be disabled, and another open request will be required to start the operator again. If after restart, the overload or an open obstacle happens again before the open limit is reached, the operator will lockout and sound the alarm.

To measure the motor load used during opening, while this function is being displayed, push and hold the OPEN button to fully open the gate. During movement, the motor current will be displayed as a load number from 0 to 99. This number is useful for troubleshooting but not for setting the motor current. At the end of travel, a different number will fl ash. This number indicates the range above and below the average motor current during the run. Using the + and - buttons, set the programmed range number so that a minimal force (50-75 lbs.) will activate a reversal should

FUNCTION

"OC"

MAX OPEN

CURRENT

OPTIONS

PRESS AND HOLD THE OPEN BUTTON UNTIL THE OPERATOR RUNS FULLY OPEN

SUGGESTED MINIMUM NUMBER WILL FLASH, ADJUST TO THE PROPER FORCE

ENTER PRESS ENTER TO STORE THE FORCE

an obstruction occur, but high enough to keep the gate moving under normal conditions without interruption.

Maximum Close Direction Current Setting

To detect obstacles or mechanical problems with the gate, the operator monitors its motor current. If the close current load exceeds the programmed maximum load range number, the operator will stop, reverse, and travel to the full open position. Should a open obstruction input or an open direction inherent entrapment condition occur prior to the gate reaching the open limit, the operator will lockout and sound the continuous tone alarm. Another close request will be required to start the operator again. If after restart, the overload or a close obstacle happens again before the close limit is reached, the operator will lockout and sound the alarm. If the auto close timer is set, when the close obstruction input is cleared, the gate will close when the auto close timer expires.

To measure the motor load used during closing, while this function is being displayed, push and hold the CLOSE button to close the gate. During movement, the motor current will be displayed as a load number from 0 to 99. This number is useful for troubleshooting but not used for setting the motor current. At the end of travel, a different number will fl ash. This number indicates the range above and below the average motor current during the run. Using the + and - buttons, set the programmed range number so that a minimal force (50-75 lbs.) will activate a reversal should an obstruction occur, but high enough to keep the gate moving under normal conditions without interruption.

FUNCTION

"CC"

MAX CLOSE

CURRENT

OPTIONS

PRESS AND HOLD THE CLOSE BUTTON UNTIL THE OPERATOR RUNS FULLY CLOSED

SUGGESTED MINIMUM NUMBER WILL

FLASH, ADJUST TO THE PROPER FORCE

ENTER PRESS ENTER TO STORE THE FORCE

VS-GSWG Swing Gate Operator Installation Guide

- 13 -

P1250 Revision X6 7-8-2011

 

Image 15
Contents VS-GSWG Table of Contents Safety Information and Warnings Pre-installation InformationWiring Specifications AC Power WiringDC Control and Accessory Wiring Mounting Pad Installation Gate PreparationMounting Specifications Operator Preparation Gate Arm InstallationVent Plug Installation Gate Arm AssemblyEarth Ground Operator SetupController Access AC Power ConnectionSetting Speeds using LSO-2 & LSC-2 Open and Close Limit AdjustmentLimit Nuts Rough Adjustment Limit Nuts Fine AdjustmentLoosen the set screw on the adjustment nut Torque Limiter AdjustmentButtons Controller FeaturesApex Function Display Indications Indicator DescriptionsTerminal Group Function Terminal DescriptionsOperator Accessory Connections Operator Accessory ConnectionsBasic Controller Programming Run Alarm and Pre-start Alarm Maximum Open Direction Current SettingMaximum Close Direction Current Setting Advanced Controller Programming Constant Pressure Mode Auxiliary Relay ModeReverse Delay Time Brake Delay TimeRadio Enable Reset Cycle CountMaintenance Alert Trigger Anti-tailgate EnableMGT Obstacle Transmitter Learn Reset Controller to Factory DefaultsRadio Transmitter Learn Radio Transmitter DeleteLoop Layout Illustration Safety Edge Layout Illustration Photoeye Installation Illustration Dual Gate Installations Open and Close Limit settingsOptional In-Cabinet Heater Operation Indications Gate OperationMGT Obstacle Transmitter Trouble Error IndicationsEntrapment Comm Link Connection FailureTroubleshooting General Preventative MaintenanceMonth Preventative Maintenance FCC NoticeModel VS-GSWG Exploded View Model SWG Mechanical Parts List Variable Speed Control Box Assemblies Controller Parts ListProgramming the Hitachi Inverter Variable Speed Drive ProgrammingShown for Clarity only not Included in ARM Assembly Gate Arm Assembly Parts ListThis page left blank intentionally Gate Operator Installation Checklist