Linear VS-GSWG manual Error Indications, Entrapment, Comm Link Connection Failure

Page 25

Error Indications

During abnormal operation, the Controller’s displays and beeper will indicate the error condition that has occurred.

Entrapment

If an entrapment condition occurs detected by two repeated open or close obstruction triggers, the Controller will lock the operator out. The beeper will sound constantly and the gate will not operate. To reset the Controller press the STOP button or press the RESET button on the operator’s cover.

WARNING

The Stop and/or Reset button must be located in the line-of- sight of the gate. Activation of the reset control shall not cause the operator to start.

COMM LINK Connection Failure

In dual gate installations, if there is a connection failure between the two operators, the COMM LINK indicator will blink once a second. During this condition the gate will not operate, except if triggered by the FIRE DEPT input, which functions normally.

MGT Obstacle Transmitter Trouble

If any MGT transmitters are used with the operator, their supervision feature will alert the Controller if there is any trouble with the transmitter. MGT transmitters send hourly status reports and will send low battery reports when the transmitter has a low battery. The MGT transmitters also have a tamper detection switch that will trigger when their case is opened.

When the Controller detects a low transmitter battery, a tamper signal, or missing transmitter status reports, the gate will still operate normally, but the beeper will change as follows:

The Pre-start Alarm will beep twice as fast.

The Run Alarm will beep twice as fast and continue for fi ve minutes after the gate stops.

The sounder will “chirp” every fi ve seconds when the gate is idle.

Correct the trouble (close case, replace battery, or replace transmitter) to clear the obstacle transmitter trouble indications.

Maximum Run Time Exceeded

If the Maximum Run Time is exceeded, the Controller stops the operator the same as if a double obstacle has occurred in an entrapment condition. The entrapment alarm sounds constantly, and is cleared by pressing the STOP button or the RESET button on the cover. After the STOP or RESET button is pressed, because the Maximum Run Time has been exceeded, the sounder will beep twice every fi ve seconds. The next operation of the gate will clear the indication.

CONTROLLER ERROR CAUSES AND INDICATIONS

ERROR CAUSE

ERROR INDICATION

HOW TO CLEAR

TWO SAFETY REVERSALS (ON

En 00, CONTINUOUS ALARM

 

SINGLE GATE OR ON EITHER

PRESS STOP BUTTON

BEEPER, GATE DISABLED

DUAL GATE)

 

 

 

 

 

PRESS STOP BUTTON,

MAXIMUM RUN TIMER

En 01, AND MAX RUN LED,

CLEARS CONTINUOUS ALARM,

CONTINUOUS ALARM BEEPER,

THEN DOUBLE BEEP EVERY

EXCEEDED ON OPENING

GATE DISABLED

5 SECONDS UNTIL NEXT

 

 

 

OPERATION

 

 

PRESS STOP BUTTON,

MAXIMUM RUN TIMER

En 02, AND MAX RUN LED,

CLEARS CONTINUOUS ALARM,

CONTINUOUS ALARM BEEPER,

THEN DOUBLE BEEP EVERY

EXCEEDED ON CLOSING

GATE DISABLED

5 SECONDS UNTIL NEXT

 

 

 

OPERATION

 

En 03, AND COMM LINK LED,

 

COMM LINK FAILURE

CONTINUOUS ALARM BEEPER

PRESS STOP BUTTON, CLEARS

FOR 1 MINUTE, GATE DISABLED

CONTINUOUS ALARM

 

 

(EXCEPT FOR FIRE DEPT INPUT)

 

GATE FULL OPEN RESULTING

En 04, GATE DISABLED

PRESS STOP BUTTON

FROM FIRE DEPT INPUT

 

 

FAIL SAFE OR FAIL SECURE

 

 

BECAUSE OF BATTERY VOLTAGE

En 05, GATE DISABLED

BATTERY VOLTAGE MUST RISE

DROP BELOW 21.6 VDC DUE TO

ABOVE 24 VDC

 

AC POWER LOSS

 

 

OTHER CONTROLLER IN

En 06, GATE DISABLED

CLEAR ENTRAPMENT ON OTHER

ENTRAPMENT (DUAL GATE)

CONTROLLER (PRESS STOP)

 

LOW AC VOLTAGE AT

En 07, GATE DISABLED

RESTORE AC POWER TO

CONTROLLER

NORMAL LEVEL

 

INPUT TRIGGERED DURING

En 08, GATE DISABLED

PRESS STOP BUTTON

ENTRAPMENT LOCKOUT

 

 

COMPATIBILITY PROBLEM

En 09, GATE DISABLED

UPDATE FIRMWARE AND RESET

BOTH PAIRED CONTROLLERS

 

 

EEPROM PROBLEM

En 10, GATE DISABLED

TRY RESET, CALL TECH. SUPPORT

 

 

REPROGRAM MOTOR TYPE OR

DC MOTOR MISMATCH

En 11, GATE DISABLED

CHANGE DC MOTOR BOARD,

NEXT GATE MOVEMENT WILL

 

 

 

 

RETRY DC MOTOR CHECK

MOTOR FAILURE

En 12, GATE DISABLED

CALL TECH. SUPPORT

AC POWER LOSS IN OPEN OR

 

 

CLOSE IMMEDIATE POWER

En 13

REAPPLY AC POWER

FAIL MODE

 

 

MAXIMUM RUN TIMER

 

BATTERY VOLTAGE MUST RISE

EXCEEDED AFTER AC POWER

En 14

ABOVE 24 VOLTS

LOSS

 

 

 

MGT SUPERVISORY CONDITION

FAST BEEPS DURING PRESTART,

CLEARS WHEN MGT CONDITION

(TAMPER, LOW BATTERY,

FAST BEEP RUN ALARM, CHIRP

CLEARS

MISSING HOURLY STATUS)

EVERY 5 SECONDS AT IDLE

 

VS-GSWG Swing Gate Operator Installation Guide

- 23 -

P1250 Revision X6 7-8-2011

 

Image 25
Contents VS-GSWG Table of Contents Safety Information and Warnings Pre-installation InformationAC Power Wiring Wiring SpecificationsDC Control and Accessory Wiring Gate Preparation Mounting Pad InstallationMounting Specifications Vent Plug Installation Gate Arm InstallationGate Arm Assembly Operator PreparationController Access Operator SetupAC Power Connection Earth GroundLimit Nuts Rough Adjustment Open and Close Limit AdjustmentLimit Nuts Fine Adjustment Setting Speeds using LSO-2 & LSC-2Loosen the set screw on the adjustment nut Torque Limiter AdjustmentButtons Controller FeaturesApex Function Display Indications Indicator DescriptionsTerminal Group Function Terminal DescriptionsOperator Accessory Connections Operator Accessory ConnectionsBasic Controller Programming Maximum Open Direction Current Setting Run Alarm and Pre-start AlarmMaximum Close Direction Current Setting Advanced Controller Programming Reverse Delay Time Auxiliary Relay ModeBrake Delay Time Constant Pressure ModeMaintenance Alert Trigger Reset Cycle CountAnti-tailgate Enable Radio EnableRadio Transmitter Learn Reset Controller to Factory DefaultsRadio Transmitter Delete MGT Obstacle Transmitter LearnLoop Layout Illustration Safety Edge Layout Illustration Photoeye Installation Illustration Open and Close Limit settings Dual Gate InstallationsOptional In-Cabinet Heater Operation Indications Gate OperationEntrapment Error IndicationsComm Link Connection Failure MGT Obstacle Transmitter TroubleTroubleshooting Month Preventative Maintenance Preventative MaintenanceFCC Notice GeneralModel VS-GSWG Exploded View Model SWG Mechanical Parts List Variable Speed Control Box Assemblies Controller Parts ListProgramming the Hitachi Inverter Variable Speed Drive ProgrammingShown for Clarity only not Included in ARM Assembly Gate Arm Assembly Parts ListThis page left blank intentionally Gate Operator Installation Checklist