Linear VS-GSWG Radio Transmitter Learn, Radio Transmitter Delete, MGT Obstacle Transmitter Learn

Page 19

Advanced Controller Programming (Cont.)

Radio Transmitter Learn

The Controller’s built-in MegaCode® radio receiver can store the IDs of up to 40 transmitters. Refer to the fi gure for the steps required to learn transmitters.

NOTE: This function will NOT be displayed if the transmitter memory is full, or if the radio receiver is disabled.

Radio Transmitter Delete

Transmitters can be deleted from the Controller’s memory either individually, or all at the same time. Refer to the fi gure for the steps required to delete transmitters.

FUNCTION

"TL"

LEARN

TRANSMITTERS

ENTER

PRESS ENTER (ONCE FOR EACH TRANSMITTER,

UP TO 40 TRANSMITTERS TOTAL)

 

"TL" WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER IS READY TO LEARN A TRANSMITTER

ACTIVATE THE TRANSMITTER

DISPLAY WILL SHOW "- -" THEN THE

TRANSMITTER ID NUMBER - IF TRANSMITTER

IS ALREADY ENTERED, "dU" WILL BE DISPLAYED, IF DECODE IS BAD "ERROR" WILL BE DISPLAYED

NOTE: This function will NOT be displayed if no transmitters are stored in memory, or if the radio receiver is disabled.

MGT Obstacle Transmitter Learn

The Controller supports one or two Model MGT Obstacle Transmitters. The transmitters can be programmed to function as Open Obstruction, Close Obstruction, Reverse, or Stop. Refer to the fi gure for the steps required to learn MGT transmitters.

NOTE: This function will NOT be displayed if two MGT transmitters are already stored in memory, or if the radio receiver is disabled.

FUNCTION

 

 

 

 

"TD"

 

ENTER

PRESS ENTER

 

 

 

 

 

 

 

 

 

 

 

 

"TD" WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IS READY TO DELETE ONE OR MORE TRANSMITTERS,

 

 

 

 

 

 

 

 

 

(TO EXIT WITHOUT DELETING ANY, PRESS ENTER)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTER

TO DELETE ALL TRANSMITTERS, PRESS ENTER FOR

 

 

 

 

 

 

2 SECONDS, OR TO PICK TRANSMITTERS GO TO NEXT STEP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESS UP OR DOWN TO SCROLL THROUGH THE LIST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UP OR DOWN

 

 

 

 

 

OF TRANSMITTER ID NUMBERS

 

 

 

 

 

 

 

 

 

THE TRANSMITTER ID NUMBER IS DISPLAYED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TO EXIT WITHOUT DELETING, PRESS ENTER)

 

 

 

 

 

 

 

 

 

(TO PICK A DIFFERENT TRANSMITTER ID, PRESS UP OR DOWN)

 

DELETE

 

 

 

 

PRESS ENTER FOR 2 SECONDS TO DELETE THE

 

 

ENTER

TRANSMITTERS

 

 

TRANSMITTER DISPLAYED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MGT Obstacle Transmitter Delete

MGT transmitters can be deleted from the Controller’s memory either individually, or all at the same time. Refer to the fi gure for the steps required to delete MGT transmitters.

NOTE: This function will NOT be displayed if no MGT transmitters are stored in memory, or if the radio receiver is disabled.

Motor Type Selection

The factory sets the default for the Controller to match the type of motor in the operator. If required, change the motor selection option to a different type of motor used in the operator. The options available are:

FUNCTION

ENTER

"ML"

UP OR DOWN

ENTER

LEARN MGT

TRANSMITTERS

PRESS ENTER, "ML" WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER IS READY TO LEARN AN MGT TRANSMITTER

ACTIVATE THE MGT TRANSMITTER, THE DISPLAY WILL FLASH "rE" - IF THE TRANSMITTER IS ALREADY ENTERED,

"DU" WILL BE DISPLAYED, IF DECODE IS BAD "ERROR" WILL BE DISPLAYED

PRESS UP OR DOWN TO SELECT THE MGT FUNCTION: "rE" = REVERSE "St" = STOP

"OP" = OPEN OBSTRUCTION "CL" = CLOSE OBSTRUCTION

PRESS ENTER TO ACCEPT THE SELECTION

DISPLAY WILL SHOW "--" FOR 5 SECONDS, THEN SHOW THE TRANSMITTER'S ID NUMBER - REPEAT STEPS FOR SECOND MGT TRANSMITTER IF USED

AC Motor Only

DC Motor Only with Mechanical Braking

DC Motor with Electronic Soft Start/Stop

3 Phase AC Motor

AC Motor with DC Motor Backup with Mechanical Braking

AC Motor with DC Motor Backup with Electronic Soft Start/Stop

Reset Controller to Factory Defaults

The Controller can be reset with this function. ALL PROGRAMMED DATA WILL BE LOST, and the factory defaults will be loaded. This function will not erase radio transmitters, current sense values, or motor type. Transmitters must be deleted with the two functions above.

FUNCTION

 

ENTER

PRESS ENTER

"MD"

 

 

 

 

"MD" WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER

 

 

 

 

 

 

 

 

 

IS READY TO DELETE ALL MGT TRANSMITTERS

TO DELETE ALL MGT TRANSMITTERS, PRESS ENTER FOR

ENTER 2 SECONDS, (TO EXIT WITHOUT DELETING ANY, QUICKLY

PRESS ENTER)

ERASE MGT

 

 

 

THE DISPLAY WILL SHOW "DELETE ALL" AND THE

 

 

 

TRANSMITTERS

 

 

 

CONTROLLER RETURNS TO PROGRAMMING MODE

 

 

 

 

 

 

 

 

 

FUNCTION

"CL"

ENTER WHILE "CL" IS DISPLAYED, PRESS ENTER

ALL PROGRAMMED DATA WILL BE CLEARED

AND THE FACTORY DEFAULTS WILL BE

STORED IN MEMORY.

NOTE: THIS FUNCTION WILL NOT ERASE

TRANSMITTERS, CURRENT SENSE VALUES,

OR MOTOR TYPE.

RESET TO

FACTORY DEFAULTS

FUNCTIONOPTIONS

"MO"

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

MOTOR TYPE

SELECTION

AC MOTOR ONLY

DC MOTOR ONLY WITH BRAKING

DC MOTOR WITH SOFT START/STOP

NOTE: SELECTION

3 PHASE AC MOTOR MUST MATCH

MOTOR BOARD!

AC MOTOR PRIMARY WITH

DC MOTOR BACKUP WITH BRAKING

AC MOTOR PRIMARY WITH

DC MOTOR BACKUP WITH SOFT START/STOP

VS-GSWG Swing Gate Operator Installation Guide

- 17 -

P1250 Revision X6 7-8-2011

 

Image 19
Contents VS-GSWG Table of Contents Safety Information and Warnings Pre-installation InformationAC Power Wiring Wiring SpecificationsDC Control and Accessory Wiring Gate Preparation Mounting Pad InstallationMounting Specifications Operator Preparation Gate Arm InstallationVent Plug Installation Gate Arm AssemblyEarth Ground Operator SetupController Access AC Power ConnectionSetting Speeds using LSO-2 & LSC-2 Open and Close Limit AdjustmentLimit Nuts Rough Adjustment Limit Nuts Fine AdjustmentLoosen the set screw on the adjustment nut Torque Limiter AdjustmentButtons Controller FeaturesApex Function Display Indications Indicator DescriptionsTerminal Group Function Terminal DescriptionsOperator Accessory Connections Operator Accessory ConnectionsBasic Controller Programming Maximum Open Direction Current Setting Run Alarm and Pre-start AlarmMaximum Close Direction Current Setting Advanced Controller Programming Constant Pressure Mode Auxiliary Relay ModeReverse Delay Time Brake Delay TimeRadio Enable Reset Cycle CountMaintenance Alert Trigger Anti-tailgate EnableMGT Obstacle Transmitter Learn Reset Controller to Factory DefaultsRadio Transmitter Learn Radio Transmitter DeleteLoop Layout Illustration Safety Edge Layout Illustration Photoeye Installation Illustration Open and Close Limit settings Dual Gate InstallationsOptional In-Cabinet Heater Operation Indications Gate OperationMGT Obstacle Transmitter Trouble Error IndicationsEntrapment Comm Link Connection FailureTroubleshooting General Preventative MaintenanceMonth Preventative Maintenance FCC NoticeModel VS-GSWG Exploded View Model SWG Mechanical Parts List Variable Speed Control Box Assemblies Controller Parts ListProgramming the Hitachi Inverter Variable Speed Drive ProgrammingShown for Clarity only not Included in ARM Assembly Gate Arm Assembly Parts ListThis page left blank intentionally Gate Operator Installation Checklist