GTO GP-SW050 owner manual Control Board Description, Exit

Page 19

Control Board Description

 

COM +12V OPEN COM

COM +12V OPEN COM

COM +12V OPEN COM

2

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXIT

 

SHADOW

 

SAFETY

 

LIMIT SENSORS

 

 

BLDC SPEED CONTROL

 

ALARM GTO LOOP DETECTORS

3

STATUS

 

 

 

 

 

AT OPEN

 

+12Vdc

ACC.

+ ACC. PWR.

LIMIT

4

 

PRISON

 

POWER

12VDC

COM

MODE

 

 

 

- 300ma

 

DUAL LINK

DUAL

DUAL

5

LINK

LINK COM

CABLE

 

 

 

 

 

 

14

13

20

 

LOCK N.C.

 

LOCK

 

 

 

 

 

 

 

 

6

LOCK COM

 

 

 

 

 

 

 

 

 

 

LOCK N.O.

 

RUNNING

12

 

 

 

RELAY

 

DIAG.

 

 

 

 

 

RUN 1

 

 

PORT

7

OUTPUTS

 

 

RUN 2

 

 

 

 

 

 

 

 

 

 

11

OPTIONS

 

 

 

CLOSED

 

 

 

 

 

8

CLOSED 1

CLOSED 2

CYCLE

10

CYCLE

OFF

OFF

<<<

DELAY MASTER SAFE

19

1

 

ON

2

 

 

3

 

 

4

 

 

 

 

 

ON

ON

>>>

SIMUL SLAVE SECURE

MODE 1

MODE 2

OPEN DIR.

SLV OPN DUAL MODE LOW BATT

9

SAFETY

SHADOW

LOOP

OPEN EDGE

CLOSE EDGE

OPEN

CLOSE

STOP

COM

COM

COM

 

 

 

 

 

 

SAFETY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHADOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPEN

 

 

 

 

 

 

 

EDGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLOSE

 

 

 

 

 

 

 

EDGE

 

 

 

 

 

 

 

OPEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLOSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM

 

 

 

 

 

STOP

 

 

 

 

 

 

 

 

W1

 

COM

 

 

 

 

 

CUT TO USE

21

 

 

 

 

 

3 BUTTON

 

 

 

 

 

 

STATION

 

COM

GTO Inc. Tallahassee, FL

SX4000 Logic Board Rev. E

STALL FORCE ADJUST

 

AUTO

CLOSE

<<<

 

>>>

TIMER

 

 

 

 

 

18

 

17

 

 

 

 

MIN

MAX

MIN

MAX

OFF

120

LIMIT ADJUSTMENTS

 

SET

 

<<<

JOG

>>>

16

LIMIT

 

 

TEST SWITCHES

 

 

CLOSE

15

STOP

 

OPEN

 

1BLDC Motor Control Connection

2Limit Sensor Connection

3Alarm / Buzzer Connection

412Vdc Accessory Power

5Dual Link Connection

6Relay Output - To Control Lock

7Relay Output - To Indicate Gate’s Running

8Relay Output - To Indicate Gate’s Closed

9Accessory Inputs

10LED Indicators - For accessory inputs

11LED Indicators - To show ‘closed’ relay is on

12LED Indicator - To Show ‘Running’ Relay is on

13LED Indicator - To Show ‘Lock’ Relay is on

14LED Indicators - To Show Dual Link Communication

15Test Switches - To Control Gate Operation

16Limit Adjustment Control Switches

17Left and Right Stall Force Adjustment

18Auto Close Timers Adjustment Potentiometer (OFF, 3-120 sec)

19DIP Switch Option Setting

20Diagnostic Port (NOT for telephone)

21W1- for 3-button Station with Normally Close ‘Stop’ Button

16

Image 19
Contents GP-SW050 Vehicular gate operator class categories Conversion ChartTable of Contents Important Safety Instructions for the System Designer III. After Installation Before InstallationMeans of Protection Against Entrapment Important Safety Instructions for the Consumer/End User Entrapment Protection Required Safety Precautions for GatesMoving Gate Can Cause Injury Or Death Motor Technical SpecificationsOperator Chassis Parts IdentificationPreparation of the Gate Installing the Gate OperatorBefore mounting the operator, check the following Using the Mounting TemplateTemplateMounting Mounting the Operator Removing the Operator Housing Not provided Connecting Power to the OperatorRight Mounted Arm Gate Arm Connection OverviewInstall the key into the output shaft. Fig Connecting the Gate Arm to the GateExit Control Board DescriptionOpen Limit Setting Setting the LimitsStall Force Adjustment Stall Force and Auto-Close AdjustmentsDIP #1 Open Direction DIP Switch SettingsInput Connections GTO Loop Detector Button Station Accessory Terminal ConnectionsSiren-Activated Entry Device Lock COM and Lock N.O. / Lock N.C. Lock relay output Output Connections12Vdc @ 300 mA Power Supply Accessory Power Supply ConnectionPrison Mode Operation Class IV Applications Wiring a 3-button stationReinstalling the Operator Housing Dual Gate Link Connection Installing a Dual Gate Operator SystemSlave DIP Switch Settings Setting Dual Gate SequenceSlave Operator Overview of a Dual Gate Operator InstallationMaintenance Schedule MaintenanceGP-SW050 Audible Feedback TroubleShooting GuideOpen Edge LED on Safety LED onCycle LED on brightly Shadow LED onStop LED on brightly Close Edge LED onOpen LED on brightly Close LED on brightlyInstructions for the Consumer/End User Warranty and Repair ServiceInstallation of this operator conforms to Class Installation ChecklistW . g t o a c c e s s . c o m