Output Connections

Note:

• Maximum rating for all relay outputs are 24Vac/dc, 1 Amp.

• All relay outputs are dry contact (no voltage) switching.

• All outputs have corresponding LED indicator for diagnostic purposes.

The corresponding LED indicator will be lit when its relay is activated.

1.CLOSED 1 and CLOSED 2: At closed limit relay output.

• These two (2) terminals are shorted when gate is at the closed limit.

2.RUN 1 and RUN 2: Gate moving relay output.

• These two (2) terminals are shorted whenever the gate is moving/running.

RUN 1

RUN 2

CLOSED 1

CLOSED 2

RELAY OUTPUTS

RUNNI

CLOSED

3.LOCK COM and LOCK N.O. / LOCK N.C.: Lock relay output

This relay output is designed for use with either mechanical or mag-lock device. The relay is activated (releasing the lock) during the first and the last 2-4 seconds of gate running.

Example A: Mag-Lock Connection: Use LOCK COM and LOCK NC terminals. The diagram below is for a typical mag-lock connection. Refer to the mag-lock manual for detailed operations.

Example B: For locks that are energized to release: Use LOCK COM and LOCK NO terminals.

Example A

Mag Lock

24vDC Max, 1 Amp Max

LOCK N.C.

LOCK COM

LOCK N.O.

To positive (+) terminal of mag-lock power supply

To negative (-) terminal of mag-lock power supply

REL

LOCK

LED11

RUNNING

Example B

Lock Coil or Controller 24vDC Max, 1Amp Max

LOCK N.C.

LOCK COM

LOCK N.O.

To positive (+) terminal of

Lock power supply

To negative (-) terminal of

Lock power supply

RE

LOCK

LED11

RUNNING

22

Image 25
Contents GP-SW050 Vehicular gate operator class categories Conversion ChartTable of Contents Important Safety Instructions for the System Designer III. After Installation Before InstallationMeans of Protection Against Entrapment Important Safety Instructions for the Consumer/End User Entrapment Protection Required Safety Precautions for GatesMoving Gate Can Cause Injury Or Death Motor Technical SpecificationsOperator Chassis Parts IdentificationPreparation of the Gate Installing the Gate OperatorBefore mounting the operator, check the following Using the Mounting TemplateTemplateMounting Mounting the Operator Removing the Operator HousingNot provided Connecting Power to the OperatorRight Mounted Arm Gate Arm Connection OverviewInstall the key into the output shaft. Fig Connecting the Gate Arm to the GateExit Control Board DescriptionOpen Limit Setting Setting the LimitsStall Force Adjustment Stall Force and Auto-Close Adjustments DIP #1 Open Direction DIP Switch SettingsInput Connections GTO Loop Detector Button Station Accessory Terminal ConnectionsSiren-Activated Entry Device Lock COM and Lock N.O. / Lock N.C. Lock relay output Output Connections12Vdc @ 300 mA Power Supply Accessory Power Supply ConnectionPrison Mode Operation Class IV Applications Wiring a 3-button stationReinstalling the Operator Housing Dual Gate Link Connection Installing a Dual Gate Operator SystemSlave DIP Switch Settings Setting Dual Gate SequenceSlave Operator Overview of a Dual Gate Operator InstallationMaintenance Schedule MaintenanceGP-SW050 Audible Feedback TroubleShooting GuideCycle LED on brightly Safety LED onShadow LED on Open Edge LED onOpen LED on brightly Close Edge LED onClose LED on brightly Stop LED on brightlyInstructions for the Consumer/End User Warranty and Repair ServiceInstallation of this operator conforms to Class Installation ChecklistW . g t o a c c e s s . c o m