Connecting the Gate Arm to the Gate
Key
Output Shaft
Fig. 1
Bolts | Reducer |
and | Arm |
Washers |
|
Fig. 2
1.Install the key into the output shaft. (Fig. 1)
2.Fit the end of the reducer arm onto the output shaft as shown and tighten the bolts. (Fig. 2)
3.Turn the power on.
4.Set DIP switch 1 to designate the operator arm as left or right (Fig. 3)
(right is shown here).
5.Manually move gate to the closed position. (Fig. 4)
OFF |
|
| ON |
OFF |
| ON | ON |
<<< | 1 | >>> | |
DELAY | 2 |
| SIMUL |
MASTER | 3 4 |
| SLAVE |
SAFE |
| SECURE |
Fig. 3
OPTIONS
MODE 1
MODE 2
OPEN DIR.
SLV OPN DUAL MODE LOW BATT
Gate Bracket
| Closed Gate |
| |
| (approx) | Operator Arm |
|
| Reducer Arm | ||
Clevis Pin | |||
| Fig. 4 |
|
|
Hairpin Clip |
| Closing | CAUTION: |
Fig. 5 |
|
| DO NOT STAND |
|
| IN THIS AREA |
6.Unfold the arm to approximately a 5-10° angle. (Fig. 4)
7.Use ‘CLOSE’ button on control board to move operator arm/reducer arm to the gate. CAUTION: Be careful not to stand in the gray area surrounding the operator. (Fig. 4) Be prepared to stop (using the ‘STOP’ button) when the gate arm and reducer arm near the desired position.
NOTE: Use ‘JOG’ buttons to fine tune the position.
8.Mark the position of the gate bracket holes on the gate, drill holes and mount bracket.
9.Fit the end of the operator arm into the gate bracket and attach using clevis pin and hairpin clip. (Fig. 5)
|
| Fig. 6 | NOTE: Gate Arm’s length can be adjusted |
| |
|
| by rotating the gate arm’s tube before |
| ||
|
|
|
|
| |
|
|
|
| mounting it to the gate bracket. (Fig. 5) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
15