GTO GP-SW050 Close Edge LED on, Open LED on brightly, Close LED on brightly, Stop LED on brightly

Page 35

S y m p t o m

D i a g n o s i s

C h e c k

Close Edge LED ON

Close Edge terminal shorted to

• Edge sensor is sensing an

brightly Status Light

Com

obstruction.

flashes

 

• Relay from edge sensor is

 

 

shorted or latched.

 

 

• Wire between edge sensor and

 

 

open edge terminal is shorted.

 

 

• Check terminal voltage with

 

 

respect to Com to ensure you

 

 

read 12 vdc.

Open LED ON brightly

Open terminal shorted to Com

• Push button is stuck.

Status Light flashes

 

• Exit wand, Loop detector,

 

 

Photo beam, etc., is sensing a

 

 

presence.

 

 

• Relay from Exit wand, Loop

 

 

detector, Photo beam, etc. is

 

 

shorted or latched.

 

 

• Wire from Exit wand, Loop

 

 

detector, Photo beam, etc. is

 

 

shorted.

 

 

• Check terminal voltage with

 

 

respect to Com to ensure you

 

 

read 12 vdc.

Close LED ON brightly

Close terminal shorted to Com

• Push button is stuck

Status Light flashes

 

• Check terminal voltage with

 

 

respect to Com to ensure you

 

 

read 12 vdc.

Stop LED ON brightly

Stop and Com terminals open.

• W1 is cut and normally open

Status Light flashes

 

button is wired to Stop and Com.

 

 

• W1 is cut and no normally

 

 

closed push button is wired to

 

 

Stop and Com.

 

 

• Wire between normally closed

 

 

push button and Stop terminal is

 

 

cut or disconnected.

 

 

• Check terminal voltage with

 

 

respect to Com to ensure you

 

 

read 0 vdc.

32

Image 35
Contents GP-SW050 Vehicular gate operator class categories Conversion ChartTable of Contents Important Safety Instructions for the System Designer III. After Installation Before InstallationMeans of Protection Against Entrapment Important Safety Instructions for the Consumer/End User Entrapment Protection Required Safety Precautions for GatesMoving Gate Can Cause Injury Or Death Motor Technical SpecificationsOperator Chassis Parts IdentificationPreparation of the Gate Installing the Gate OperatorBefore mounting the operator, check the following Using the Mounting TemplateTemplateMounting Mounting the Operator Removing the Operator HousingNot provided Connecting Power to the OperatorRight Mounted Arm Gate Arm Connection OverviewInstall the key into the output shaft. Fig Connecting the Gate Arm to the GateExit Control Board DescriptionOpen Limit Setting Setting the LimitsStall Force Adjustment Stall Force and Auto-Close AdjustmentsDIP #1 Open Direction DIP Switch SettingsInput Connections Siren-Activated Entry Device Accessory Terminal ConnectionsGTO Loop Detector Button Station Lock COM and Lock N.O. / Lock N.C. Lock relay output Output Connections12Vdc @ 300 mA Power Supply Accessory Power Supply ConnectionPrison Mode Operation Class IV Applications Wiring a 3-button stationReinstalling the Operator Housing Dual Gate Link Connection Installing a Dual Gate Operator SystemSlave DIP Switch Settings Setting Dual Gate SequenceSlave Operator Overview of a Dual Gate Operator Installation Maintenance Schedule MaintenanceGP-SW050 Audible Feedback TroubleShooting GuideOpen Edge LED on Safety LED onCycle LED on brightly Shadow LED onStop LED on brightly Close Edge LED onOpen LED on brightly Close LED on brightlyInstructions for the Consumer/End User Warranty and Repair ServiceW . g t o a c c e s s . c o m Installation ChecklistInstallation of this operator conforms to Class