GTO GP-SW050 owner manual DIP Switch Settings, DIP #1 Open Direction

Page 22

DIP Switch Settings

MODE 1 & MODE 2:

Reserved for future features

DIP #1: OPEN DIRECTION

OFF: for gate that opens to the left, closes to the right.

ON: for gate that opens to the right, closes to the left.

DIP #2: SLAVE OPEN SEQUENCE (dual gate installation only)

• NOTE: This DIP switch is applicable if and only if all the following conditions are valid:

• DIP switch #3 is OFF (Master mode)

Dual Link cable is connected.

Slave mode is detected from the second board (DIP switch #3 of the second board is ON)

If the above conditions are not met, the board will default to single gate operation. If DIP #3 is OFF (Master)

OFF: Slave gate will open after the master gate.

ON: Slave gate will open simultaneously with the master gate.

1

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

ON

 

 

 

 

 

 

DIP #3: MASTER/SLAVE (applicable to dual gate installation only)

NOTE: This DIP switch is applicable if and only if all the following conditions are valid:

Dual Link cable is connected.

The second operator is detected by the master.

If the above conditions are not met, the board will default to single mode operation. If DIP #3 is OFF (Master)

OFF: Master mode operation in dual gate installation if slave setting is detected from the other board.

ON: Slave mode operation in dual gate installation if master setting is detected from the other board. Control board is non- functional if master operator is not detected.

DIP #4: FAIL SAFE/FAIL SECURE OPERATION

OFF: Fail safe mode

When low battery and no AC power conditions are detected the gate will automatically run to the opened position. The gate will remain at the open position until AC power is restored and the battery reaches an acceptable charge level.

ON: Fail secure mode

When low battery is detected and no AC power is present, the gate will automatically run to the closed position. Gate will auto close only if auto close feature is enabled and gate is at open limit. The gateRUN will1 Y remain at the closedLED10 position until AC

RUN 2 OUTPUTS battery reaches an

acceptable charge level. CLOSED power is restored and the

These switches are for dual gate applications only. See page 26 for dual gate settings.

PORT

OPTIONS

CLOSED 1

LED09

 

CLOSED 2

 

CYCLE

CYCLE

SAFETY

SAFETY

SHADOW

SHADOW

LOOP

 

OPEN EDGE

OPEN

EDGE

 

19

OFF

 

 

 

 

ON

OFF

 

 

 

 

ON

<<<

1

 

 

ON

>>>

DELAY

 

 

SIMUL

2

 

 

 

 

 

 

 

 

 

MASTER

3 4

 

 

 

SLAVE

 

 

 

 

 

 

SAFE

 

 

 

SECURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STALL FORCE ADJUST

<<<>>>

MODE 1

MODE 2

OPEN DIR.

SLV OPN DUAL MODE LOW BATT

AUTO CLOSE

TIMER

Image 22
Contents GP-SW050 Conversion Chart Vehicular gate operator class categoriesTable of Contents Important Safety Instructions for the System Designer Before Installation III. After InstallationMeans of Protection Against Entrapment Important Safety Instructions for the Consumer/End User Required Safety Precautions for Gates Entrapment ProtectionMoving Gate Can Cause Injury Or Death Technical Specifications MotorParts Identification Operator ChassisInstalling the Gate Operator Preparation of the GateUsing the Mounting Template Before mounting the operator, check the followingTemplateMounting Removing the Operator Housing Mounting the OperatorConnecting Power to the Operator Not providedGate Arm Connection Overview Right Mounted ArmConnecting the Gate Arm to the Gate Install the key into the output shaft. Fig Control Board Description ExitSetting the Limits Open Limit SettingStall Force and Auto-Close Adjustments Stall Force AdjustmentDIP Switch Settings DIP #1 Open DirectionInput Connections GTO Loop Detector Button Station Accessory Terminal ConnectionsSiren-Activated Entry Device Output Connections Lock COM and Lock N.O. / Lock N.C. Lock relay outputAccessory Power Supply Connection 12Vdc @ 300 mA Power SupplyWiring a 3-button station Prison Mode Operation Class IV ApplicationsReinstalling the Operator Housing Installing a Dual Gate Operator System Dual Gate Link ConnectionSetting Dual Gate Sequence Slave DIP Switch SettingsOverview of a Dual Gate Operator Installation Slave OperatorMaintenance Maintenance ScheduleTroubleShooting Guide GP-SW050 Audible FeedbackShadow LED on Safety LED onCycle LED on brightly Open Edge LED onClose LED on brightly Close Edge LED onOpen LED on brightly Stop LED on brightlyWarranty and Repair Service Instructions for the Consumer/End UserInstallation of this operator conforms to Class Installation ChecklistW . g t o a c c e s s . c o m