GE FVR-C9S-2UX Drive Series instruction manual Contents

Page 3

FVR-C9S-2UX

Thank you for purchasing the Fuji “FVR-C9S” drive, marketed by GE Fuji Drives USA, Inc. This instruction manual is included with the drive and equipment and is provided for the convenience of the end user. Please be sure it accompanies the drive.

CONTENTS

 

0.

Safety Precautions

4

1.

Inspection Upon Receipt

6

2.

Part Names

7

3.

Warning and Caution

7

4.

Specifications

8

5.

External Dimensions

10

6.

Installation Instructions

13

7.

Wiring

13

8.

Basic Wiring Diagrams

15

9.

Application of Wiring and Equipment

17

10.

Terminal Function Explanation

18

11.

Operation

20

12.

Keypad Panel

22

13.

Function Explanation

24

14.

Protective Functions

35

15.

Warranty Parts and Service

36

3

Image 3
Contents FVR-C9S-2UX Drive Series Product specifications are subject to change without notice Contents Wiring Fire and Electric Shock Hazard Safety PrecautionsOperation Electric Shock Hazard Nameplate Inspection Upon ReceiptType Part NamesInput power Voltage/frequency Supply voltage 3% SpecificationsType FVR C9S-2UX F12 F25 F50 DWG 1 FVRF12C9S-2UX to FVROO1C9S-2UX External DimensionsDWG 2 FVR002C9S to FVR003C9S-2UX FVR005C9S-2UX Mounting Direction and Space Installation InstructionsWiring Installation ConditionsDisconnect CRG Lamp Basic Wiring Diagrams 30CKeypad Panel Operation FAB External Signal OperationApplicable motor output Hp Drive type Application of Wiring and EquipmentTerminal Function Explanation Terminal Function ExplanationTerminal Function Explanation Test Run Check Points Frequency Setting MethodOperation Pre-Operation InspectionRUN/STOP Selecting Operation MethodKeypad Panel Part Names and FunctionsControlling Method for Keypad Panel Function setting method Function Code Tables Function ExplanationMotor Running Code 3 Maximum Frequency 1 Frequency Command2 Operation Command 0 Data ProtectionLow High Torque Boost8 Electronic Thermal Overload Relay Electronic Thermal Overload Relay Level30% 1 Gain for Frequency Setting Signal 2 DC Brake3 DC Brake Braking Time 6 Fault Memory 4 Starting Frequency5 Motor Running Sound Jump Frequency Range 9 Motor Characteristics7 Data Initialization 8 Retry8 BX Terminal Function 4 High Limiter F 2 5 Low Limiter6 Bias Frequency 7 THR Terminal FunctionMultistep Speed Setting 1 Speed Multistep Speed Setting 2 SpeedMultistep Speed Setting 3 Speed 3 FM Terminal Function Selection 2 FM Terminal Output Level CalibrationOC3 Protective FunctionsMotors Warranty Parts and ServiceTechnical Services GE Fuji Drives USA, Inc Out-of-Warranty ProceduresLatest Fault Previous Faults No Message In-Warranty Failure ChecklistFVR-C9S-2UX FVR-C9S-2UX FVR-C9S-2UX