Output frequency

FVR-C9S-2UX

F 1 4 Starting Frequency

The starting frequency can be set in increments of 1 Hz within a range of 1 to 6 Hz. Note that stopping will also occur at the frequency set by this function.

11 Hz

66 Hz

Set to 2 Hz when using a high speed motor.

Starting frequency

1

F 1 5 Motor Running Sound

The sound of the motor operation can be changed by changing the carrier frequency.

0Select from among 5 levels in accordance with the usage conditions.

Data code

0 Low carrier frequency

5 High carrier frequency (low noise)

F 1 6 Fault Memory

The current and previous 3 fault events are stored in memory.

The data for each can be displayed by using the DOWN key.

The procedure for displaying the data is as follows:

 

 

 

 

 

 

 

 

 

Display

 

No.

 

 

 

Procedure

 

 

(ex)

 

Remarks

1

 

 

 

Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

1

6

 

 

F

1

6

 

2

Press FUNC/DATA Key

 

 

Press UP Key

 

 

 

The information for the latest

 

 

 

 

 

trip will be displayed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

0

1

 

3

 

Press DOWN Key

 

 

Press UP Key

 

 

 

The information for the first

 

 

 

 

 

 

preceding trip will be displayed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

H

2

 

4

 

Press DOWN Key

 

 

Press UP Key

 

 

 

The information for the second

 

 

 

 

 

 

preceding trip will be displayed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

C

1

 

 

 

 

 

 

 

 

 

 

 

 

 

The information for the third

5

 

Press DOWN Key

 

 

Press UP Key

 

 

 

preceding trip will be displayed.

 

 

 

 

 

 

(in this example, there is no

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

history of a third preceding trip).

 

 

 

 

 

 

 

 

 

-

-

-

 

6

 

Press DOWN Key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

n

d

 

C92-12

The information for any new trip will be stored in the area for the "information for the latest trip" shown above, each trip history will be removed downward and the "information for the third preceding trip" will be erased.

30

Image 30
Contents FVR-C9S-2UX Drive Series Product specifications are subject to change without notice Contents Safety Precautions Wiring Fire and Electric Shock HazardOperation Electric Shock Hazard Inspection Upon Receipt NameplatePart Names TypeSpecifications Input power Voltage/frequency Supply voltage 3%Type FVR C9S-2UX F12 F25 F50 External Dimensions DWG 1 FVRF12C9S-2UX to FVROO1C9S-2UXDWG 2 FVR002C9S to FVR003C9S-2UX FVR005C9S-2UX Installation Conditions Installation InstructionsWiring Mounting Direction and SpaceDisconnect CRG Lamp Basic Wiring Diagrams 30CKeypad Panel Operation External Signal Operation FABApplication of Wiring and Equipment Applicable motor output Hp Drive typeTerminal Function Explanation Terminal Function ExplanationTerminal Function Explanation Pre-Operation Inspection Frequency Setting MethodOperation Test Run Check PointsSelecting Operation Method RUN/STOPKeypad Panel Part Names and FunctionsControlling Method for Keypad Panel Function setting method Function Explanation Function Code TablesMotor Running Code 0 Data Protection 1 Frequency Command2 Operation Command 3 Maximum FrequencyElectronic Thermal Overload Relay Level Torque Boost8 Electronic Thermal Overload Relay Low High30% 1 Gain for Frequency Setting Signal 2 DC Brake3 DC Brake Braking Time 6 Fault Memory 4 Starting Frequency5 Motor Running Sound 8 Retry 9 Motor Characteristics7 Data Initialization Jump Frequency Range7 THR Terminal Function 4 High Limiter F 2 5 Low Limiter6 Bias Frequency 8 BX Terminal FunctionMultistep Speed Setting 1 Speed Multistep Speed Setting 2 SpeedMultistep Speed Setting 3 Speed 2 FM Terminal Output Level Calibration 3 FM Terminal Function SelectionProtective Functions OC3Out-of-Warranty Procedures Warranty Parts and ServiceTechnical Services GE Fuji Drives USA, Inc MotorsIn-Warranty Failure Checklist Latest Fault Previous Faults No MessageFVR-C9S-2UX FVR-C9S-2UX FVR-C9S-2UX