GE FVR-C9S-2UX Drive Series instruction manual Part Names, Type

Page 7

1. Type

Drive Series

FVR-C9S-2UX

3. Warning and Caution

F V R F 2 5 C 9 S 2 U X

Power Series: 230V UX Series Applicable motor output (Hp)

2.Phase: 3PH - three-phase

3.Voltage range: 200V - 230V - AC200V Series

4.Frequency: 50/60Hz

5.Rated output capacity

6.Rated output current

7.Output frequency range: 1- 120 Hz

8.Serial No.

2. Part Names

4

2

PRG

RUN

RESET

 

FUNC

STOP

DATA

 

FVR-C9S

3

1

CLOSED OPEN

4

5

Improper wiring will result in damage to, and failure of the unit. Please carefully note the items listed below, and use the unit as indi- cated.

WARNING AND CAUTION

1.Do not impress power supply voltage that exceeds the standard specification volt- age permissible fluctuation. (Permissible voltage: AC200V - 230V)

2.Do not connect power supply to the drive output terminals (U, V, W). Connect power supply only to the power terminals (L1, L2 and L3)

3.Whenever removing the drive cover, al- ways switch off the power supply. Do not switch on the power supply to the drive with the drive cover removed.

4.Do not touch the live part until the CRG lamp located above the main circuit termi- nals goes out.

5.Avoid using a magnetic contactor (ON/ OFF) installed in the line side of the drive for RUN and STOP. Use the FWD-CM (forward) and REV-CM (reverse) terminals for RUN and STOP.

6.Do not connect a power factor correcting capacitor to the output side of the drive.

7.Do not perform a megger test between the drive terminals or on the control circuit terminals.

1.Drive Cover

2.Keypad Panel

3.Frequency Setting VR

4.Mounting Screw Holes

5.Drive Cover Screw

7

Image 7
Contents FVR-C9S-2UX Drive Series Product specifications are subject to change without notice Contents Wiring Fire and Electric Shock Hazard Safety PrecautionsOperation Electric Shock Hazard Nameplate Inspection Upon ReceiptType Part NamesInput power Voltage/frequency Supply voltage 3% SpecificationsType FVR C9S-2UX F12 F25 F50 DWG 1 FVRF12C9S-2UX to FVROO1C9S-2UX External DimensionsDWG 2 FVR002C9S to FVR003C9S-2UX FVR005C9S-2UX Mounting Direction and Space Installation InstructionsWiring Installation ConditionsDisconnect CRG Lamp 30C Basic Wiring DiagramsKeypad Panel Operation FAB External Signal OperationApplicable motor output Hp Drive type Application of Wiring and EquipmentTerminal Function Explanation Terminal Function ExplanationTerminal Function Explanation Test Run Check Points Frequency Setting MethodOperation Pre-Operation InspectionRUN/STOP Selecting Operation MethodPart Names and Functions Keypad PanelControlling Method for Keypad Panel Function setting method Function Code Tables Function ExplanationMotor Running Code 3 Maximum Frequency 1 Frequency Command2 Operation Command 0 Data ProtectionLow High Torque Boost8 Electronic Thermal Overload Relay Electronic Thermal Overload Relay Level30% 2 DC Brake 1 Gain for Frequency Setting Signal3 DC Brake Braking Time 4 Starting Frequency 6 Fault Memory5 Motor Running Sound Jump Frequency Range 9 Motor Characteristics7 Data Initialization 8 Retry8 BX Terminal Function 4 High Limiter F 2 5 Low Limiter6 Bias Frequency 7 THR Terminal FunctionMultistep Speed Setting 2 Speed Multistep Speed Setting 1 SpeedMultistep Speed Setting 3 Speed 3 FM Terminal Function Selection 2 FM Terminal Output Level CalibrationOC3 Protective FunctionsMotors Warranty Parts and ServiceTechnical Services GE Fuji Drives USA, Inc Out-of-Warranty ProceduresLatest Fault Previous Faults No Message In-Warranty Failure ChecklistFVR-C9S-2UX FVR-C9S-2UX FVR-C9S-2UX