GE FVR-C9S-2UX Drive Series instruction manual Type FVR C9S-2UX F12 F25 F50

Page 9

FVR-C9S-2UX

Type (FVR _ _ _ C9S-2UX)

 

F12

 

F25

F50

 

001

002

 

003

 

005

Applicable motor output1

[Hp]

1/8

 

1/4

1/2

 

1

2

 

3

 

5

 

Frequency setting

 

Key operation:

Setting with UP/DOWN keys

 

 

 

 

 

 

Potentiometer:

Terminal for 1-5K ohm VR is provided

 

 

 

 

Analog signal:

0-5 VDC 0-10 VDC

 

 

 

 

 

 

 

 

 

(input resistance = 22k ohm)

 

 

 

 

Display

Run mode

Output frequency is displayed. (3 digit LED)

 

 

 

 

 

Fault mode

Cause of fault is displayed.

 

 

 

 

 

 

 

 

Other

LED comes on with charging voltage applied.

 

 

 

 

Acceleration/Deceleration time

0-60s (Variable setting) Acceleration time and deceleration

 

Control

 

 

time can be set independently.

 

 

 

 

 

 

Voltage frequency characteristics

Setting of maximum frequency/base frequency is variable.

 

 

Restart after momentary power failure

"Automatic restart" setting makes it possible to keep motor

 

 

 

 

running and restart drive in case of a momentary power failure.

 

High Limiter & Low Limiter

Upper limit and lower limit of frequency can be set.

 

 

 

 

Bias setting

 

Bias setting is possible with respect to analog frequency setting.

 

Jump frequency

 

Three jump points and one jump width can be set.

 

 

 

 

Torque boost

 

Setting variable in 32 steps.

 

 

 

 

 

 

 

Starting torque

[%]

150% for 60 seconds

 

 

 

 

 

 

 

Braking torque5

[%]

150% 1 min.

100% 1 min.

50% 1 min.

 

30% 1 min.

Braking

DC brake

 

Brake starting frequency: 3 Hz (fixed)

 

 

 

 

 

 

Setting of braking current / braking time is variable.

 

 

Overload

 

Detects overload current and stops drive.

 

 

 

 

Momentary overcurrent

 

Protects drive In case of ground fault (detects at start) and

 

 

 

 

short circuit of output circuit.

 

 

 

 

 

 

 

Overvoltage

 

Detects overvoltage of DC bus and stops drive.

 

 

 

Protection

Overheating of cooling element

Detects abnormal temp. rise of cooling element and stops drive.

 

Motor protection

 

Protects standard 4-pole motor and forced-air cooled motor by

 

 

 

means of electronic thermal overload relay.

 

 

 

 

Alarm protection

 

Outputs contact signal in case of a trip for protection

 

 

 

 

(1c contact capacity: AC250V

0.3A

cos = 0.3)

 

 

 

 

Installation location

 

Indoor at an altitude of 3283 feet (1000m) or less and free of

 

 

 

 

dust, corrosive gas and oil mist.

 

 

 

 

 

 

Ambient temperature

 

-10 to 50°C

 

 

 

 

 

 

 

 

 

 

Ambient humidity

 

20 -90% RH (There shall be no dew condensation)

 

 

 

Environment

Vibration

 

19 feet/s2 (5.9m/s2) or less

 

 

 

 

 

 

 

 

 

Vibration frequency: 5 - 55 Hz

 

 

 

 

 

 

 

Storage temperature

 

-25 to 65°C

 

 

 

 

 

 

 

 

 

 

Atmospheric pressure

 

Operation/storage: min 900 mb (equivalent to 3283 feet (1000m)

 

 

 

Transport: min 660 mb (equivalent to 10720 feet (3265m)

 

 

Enclosure

 

IP20

 

 

 

 

 

 

 

 

 

Cooling method

 

 

Self-cooling

 

Forced-air cooling

 

5) This indicates average braking torque of a single motor. (Value varies according to motor efficiency.)

9

Image 9
Contents FVR-C9S-2UX Drive Series Product specifications are subject to change without notice Contents Wiring Fire and Electric Shock Hazard Safety PrecautionsOperation Electric Shock Hazard Nameplate Inspection Upon ReceiptType Part NamesInput power Voltage/frequency Supply voltage 3% SpecificationsType FVR C9S-2UX F12 F25 F50 DWG 1 FVRF12C9S-2UX to FVROO1C9S-2UX External DimensionsDWG 2 FVR002C9S to FVR003C9S-2UX FVR005C9S-2UX Wiring Installation InstructionsInstallation Conditions Mounting Direction and SpaceDisconnect CRG Lamp Basic Wiring Diagrams 30CKeypad Panel Operation FAB External Signal OperationApplicable motor output Hp Drive type Application of Wiring and EquipmentTerminal Function Explanation Terminal Function ExplanationTerminal Function Explanation Operation Frequency Setting MethodPre-Operation Inspection Test Run Check PointsRUN/STOP Selecting Operation MethodKeypad Panel Part Names and FunctionsControlling Method for Keypad Panel Function setting method Function Code Tables Function ExplanationMotor Running Code 2 Operation Command 1 Frequency Command0 Data Protection 3 Maximum Frequency8 Electronic Thermal Overload Relay Torque BoostElectronic Thermal Overload Relay Level Low High30% 1 Gain for Frequency Setting Signal 2 DC Brake3 DC Brake Braking Time 6 Fault Memory 4 Starting Frequency5 Motor Running Sound 7 Data Initialization 9 Motor Characteristics8 Retry Jump Frequency Range6 Bias Frequency 4 High Limiter F 2 5 Low Limiter7 THR Terminal Function 8 BX Terminal FunctionMultistep Speed Setting 1 Speed Multistep Speed Setting 2 SpeedMultistep Speed Setting 3 Speed 3 FM Terminal Function Selection 2 FM Terminal Output Level CalibrationOC3 Protective FunctionsTechnical Services GE Fuji Drives USA, Inc Warranty Parts and ServiceOut-of-Warranty Procedures MotorsLatest Fault Previous Faults No Message In-Warranty Failure ChecklistFVR-C9S-2UX FVR-C9S-2UX FVR-C9S-2UX