Approximate DC 6.5V at full scale Approximate DC 10.3V at full scale

FVR-C9S-2UX

F 3 2 FM Terminal Output Level Calibration

Adjust the level of the voltage output to terminal FM for the frequency meter. 0

9 9

FM

CM

Note: The FM terminal output is a pulse output of which frequency is constant (38.1 Hz) and duty is variable.

F 3 3 FM Terminal Function Selection

With regard to the data outputted to the FM terminal, either the output frequency or the output current can be selected.

0Output frequency

1Output current

34

Image 34
Contents FVR-C9S-2UX Drive Series Product specifications are subject to change without notice Contents Safety Precautions Wiring Fire and Electric Shock HazardOperation Electric Shock Hazard Inspection Upon Receipt NameplatePart Names TypeSpecifications Input power Voltage/frequency Supply voltage 3%Type FVR C9S-2UX F12 F25 F50 External Dimensions DWG 1 FVRF12C9S-2UX to FVROO1C9S-2UXDWG 2 FVR002C9S to FVR003C9S-2UX FVR005C9S-2UX Installation Conditions Installation InstructionsWiring Mounting Direction and SpaceDisconnect CRG Lamp 30C Basic Wiring DiagramsKeypad Panel Operation External Signal Operation FABApplication of Wiring and Equipment Applicable motor output Hp Drive typeTerminal Function Explanation Terminal Function ExplanationTerminal Function Explanation Pre-Operation Inspection Frequency Setting MethodOperation Test Run Check PointsSelecting Operation Method RUN/STOPPart Names and Functions Keypad PanelControlling Method for Keypad Panel Function setting method Function Explanation Function Code TablesMotor Running Code 0 Data Protection 1 Frequency Command2 Operation Command 3 Maximum FrequencyElectronic Thermal Overload Relay Level Torque Boost8 Electronic Thermal Overload Relay Low High30% 2 DC Brake 1 Gain for Frequency Setting Signal3 DC Brake Braking Time 4 Starting Frequency 6 Fault Memory5 Motor Running Sound 8 Retry 9 Motor Characteristics7 Data Initialization Jump Frequency Range7 THR Terminal Function 4 High Limiter F 2 5 Low Limiter6 Bias Frequency 8 BX Terminal FunctionMultistep Speed Setting 2 Speed Multistep Speed Setting 1 SpeedMultistep Speed Setting 3 Speed 2 FM Terminal Output Level Calibration 3 FM Terminal Function SelectionProtective Functions OC3Out-of-Warranty Procedures Warranty Parts and ServiceTechnical Services GE Fuji Drives USA, Inc MotorsIn-Warranty Failure Checklist Latest Fault Previous Faults No MessageFVR-C9S-2UX FVR-C9S-2UX FVR-C9S-2UX