Page 17
3.1.6Mode Selection Switch
Various modes can be implemented with the rear panel Mode Selection switch. The Mode Selection switch works in conjunction with the Up/Down switch and 
TABLE 6. Mode Selection Switch
Mode Selection  | Mode Information  | Up/Down Switch  | Functions  | 
Switch Position  | |||
  | 
  | 
  | 
  | 
0  | Normal Mode  | Display Mode (D)  | 
  | 
  | 
  | 
  | 
  | 
1  | Set Gain  | Up/Down  | Change gain  | 
  | 
  | 
  | 
  | 
2  | Set Vtop (A/D)  | Up/Down  | Change A/D ref. top  | 
  | 
  | 
  | 
  | 
3  | Set Vbottom(A/D)  | Up/Down  | Change A/D ref. bottom  | 
  | 
  | 
  | 
  | 
4  | Gain Selection #1  | Up: 9dB, Down: 12dB  | Lower gain selection  | 
  | 
  | 
  | 
  | 
5  | Gain Selection #2  | Up: 18dB, Down: 22dB  | Higher gain selection  | 
  | 
  | 
  | 
  | 
6  | Linear LUT  | Up: Linear, Down: LUT  | Linear/LUT selection  | 
  | 
  | 
  | 
  | 
7  | Knee Selection  | Up/Down (Scroll)  | Scroll 10 different LUTs  | 
  | 
  | 
  | 
  | 
8  | Async Reset Mode  | Up: Normal, Down:  | Async and normal shut-  | 
  | 
  | Async  | ter  | 
  | 
  | 
  | 
  | 
9  | Factory default Recall  | Up/Down: Recall  | Factory setting  | 
  | 
  | 
  | 
  | 
A  | Power up Setting  | Up: Recall, Down: Save  | Power up page setting  | 
  | 
  | 
  | 
  | 
B  | User Page Storage #1  | Up: Recall, Down: Save  | User page storage setting  | 
  | 
  | 
  | 
  | 
C  | User Page Storage #2  | Up: Recall, Down: Save  | User page storage setting  | 
  | 
  | 
  | 
  | 
D  | Direct Shutter Control  | Up/Down  | Shutter speed increment  | 
  | 
  | 
  | by 1H  | 
  | 
  | 
  | 
  | 
E  | Scan Format2  | Up: Optional, Down:  | |
  | 
  | Binning  | tion  | 
  | 
  | 
  | 
  | 
F  | Scan Format1  | Up: Normal, Down:  | Custom option scanning  | 
  | 
  | Normal  | 
  | 
  | 
  | 
  | 
  | 
Operation