( 7 ) Setting to factory setting status
All the settings can be returned to the factory default status (preset status).
(1)If characters are displayed on the screen, press the [DISP] button to disable the character display.
(2)Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.
(3)The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed for approx. 1 second.
7. 3 Synchro. Scan Operation
The shutter speed can be set by the double horizontal scanning period (2H) or by the frame.
( 1 ) Setting by 2H
2H/1592H ~ 1590H/1592H stands for the setting by the 2H and the shutter speed can be set by the 2H (62.8 ∝s).
When operating Partial Scannig, the number’s listed below can be used for setting.
25fps, E25fps | 2H/1270H ~ 1268H/1270H |
30fps, E30fps | 2H/1060H ~ 1058H/1060H |
35fps, E35fps | 2H/910H ~ 908H/910H |
40fps, E40fps | 2H/774H ~ 772H/774H |
45fps, E45fps | 2H/706H ~ 704H/706H |
50fps, E50fps | 2H/636H ~ 634H/636H |
( 2 ) Setting by the frame
2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.
(Internal VD)
RGB data (video interval image)
FVAL
LVAL,
DAVL
n
n+1
(4FRM setting)
23