(1. 3. 2) Changing each setting in 1P SR mode
Move up down | Set by pushing | |
By pushing | ||
DATA UP, DOWN | ||
MENU UP, DOWN | ||
|
| |
MODE | E.TRG |
E.TRG | 1P SR |
TRG.P |
|
EXP. | 50ms |
PART | OFF |
<MODE = E.TRG E.TRG = 1P SR>
•Sutter mode MANU, SS, E.TRG, RR
•E.TRG mode
1P SNR, 1P SR, PW SNR, PW SR
•Input trigger pulse setting at 1P SNR and 1P SR
Input trigger pulse : positive polarity
Input trigger pulse : negative polarity
•Exposure time setting at 1P SNR and 1P SR
0.01ms0.02 ms 0.4 ms 1 ms20 ms50 ms
0.01 ms | 0.02 ms | 0.1 ms | 1 ms | 2 ms |
step | step | step | step | step |
•Partial scanning switch OFF/25fps/30fps/35fps/40fps/45fps/50fps/ E25fps/E30fps/E35fps/E40fps/E45fps/E50fps
(a) Changing the polarity of inputting trigger pulse setting
1Set the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2Select either , by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SR exposure time setting
1Set the "→" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
2Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
(c) Changing the partial scanning setting
1Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2Select the mode by pushing [DATA UP], [DATA DOWN] buttons.
16