Toshiba IK-TF9U Partial Read, Partial Scanning OFF All pixels scanning, Partial Scanning on, CC2

Page 29

7. 5 Partial Read

( 1 ) Partial Scanning OFF (All pixels scanning)

In this mode, all pixels independent signal from the DIGITAL connector is output each 1/20 second (Line order output).

Video interval image

1/20s (1592H)

( 2 ) Partial Scanning ON

In this mode, the pixel signal of the vertical center portion from the DIGITAL connector is output.

In the E.✽✽fps mode, the partial scanning and the all pixels scanning can be switched by the DIGITAL terminal (CC2: partial scanning control signal).

CC2

E.25fps

 

E.30fps

 

E.35fps

E.40fps

 

E.45fps

E.50fps

 

 

 

 

 

 

 

‘L’

Partial scanning 25fps

Partial scanning 30fps

Partial scanning 35fps

Partial scanning 40fps

Partial scanning 45fps

Partial scanning 50fps

 

 

 

 

 

 

 

‘H’

All pixels scanning

All pixels scanning

All pixels scanning

All pixels scanning

All pixels scanning

All pixels scanning

 

 

 

 

 

 

 

 

 

 

Video interval

 

 

 

 

 

 

 

 

image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/25s (1270H): When 25fps is selected

1/40s (774H): When 40fps is selected

 

 

 

 

1/30s (1060H): When 30fps is selected

1/45s (706H): When 45fps is selected

 

 

 

 

1/35s (910H): When 35fps is selected

1/50s (636H): When 50fps is selected

 

 

( 3 ) When Partial Scanning Mode is ON

(Internal VD)

FVAL

LVAL,

DVAL

RGB data (video interval image)

Blanking interval

Video interval

Blanking interval

B

C

D

 

 

 

 

 

Video period

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode

Total A

Blanking interval B

Video interval C

Blanking interval D

25fps

1270H

40H

1024H

26H

 

 

 

 

 

30fps

1060H

56H

972H

32H

 

 

 

 

 

 

35fps

 

910H

66H

792H

52H

40fps

 

774H

78H

644H

52H

 

 

 

 

 

 

45fps

 

706H

80H

564H

62H

 

 

 

 

 

 

50fps

 

636H

86H

480H

70H

Total

A

29

Image 29
Contents Following information is only for EU-member states IK-TF9USafety Precautions Disclaimer Table of Contents Components Names and Functions Standard Connection Connector Pin AssignmentsConnection White Balance OperationAutomatic Black Balance Temp LOW Result displayed MeaningAvailable selections Items Controlled by Using on Screen DisplayUsing the Menus Mode Setting by on Screen DisplayShutter Electronic shutter MenusFlicker may be large TRGMode = Manual Changing each setting in Manu modePartial scanning setting Menu UP, DownChanging the shutter speed setting Changing each setting in SS synchro. scan modeMode = SS Changing each setting in 1P SNR mode Changing each setting in E.TRG modeChanging the polarity of inputting trigger pulse setting Changing 1P SNR exposure time settingMode = E.TRG E.TRG = 1P SR Changing each setting in 1P SR modeChanging 1P SR exposure time setting 1P SNR, 1P SR, PW SNR, PW SRMode = E.TRG E.TRG = PW SNR Changing each setting in PW SNR modeMode = E.TRG E.TRG = RR Changing each setting in PW SR modeMode = E.TRG E.TRG = PW SR Gain Video gain Changing each setting in GainChanging the gain in Manu mode WHT BAL White balance Changing gamma correction MANU/OFFChanging master pedestal Changing R pedestalOption SyncSetting to factory setting status Setting by the frameSetting by 2H Synchro. Scan Operation1 Pulse Trigger SYNC-NON Reset Picture Output Timing 1P SNR 1 Pulse Trigger Sync Non ResetE. TRG External trigger Fval Lval Dval1 Pulse Trigger SYNC-RESET Picture Output Timing 1P SR 1 Pulse Trigger Sync ResetPulse Width Trigger SYNC-NON Reset Picture Output Timing PW SNR Pulse width trigger SYNC-NON Reset1 Pulse Width Trigger SYNC-RESET Picture Output Timing PW SR Pulse width trigger SYNC-RESETLong Term Exposure RR Reset restartInput Timing Chart Example Partial Read When Partial Scanning Mode is onPartial Scanning OFF All pixels scanning Partial Scanning onUsing the unit with external sync signal External sync signal polarityExternal Sync External sync frequency rangeHorizontal Output Waveform Timing Chart Output Waveform Timing ChartVertical Output Waveform Timing Chart Fval LVAL、 DvalRGB, 3CCD SpecificationsSymptom Items to be checked External Appearance DiagramBefore Making a Service Call One 1 Year Limited Warranty of Labor and Parts Limited Warranty Toshiba CCD CameraHow to Obtain Warranty Service Step-By-Step Procedures Your Responsibilities