Toshiba IK-TF9U instruction manual Specifications, RGB, 3CCD

Page 32

9. SPECIFICATIONS

Power supply

12V DC±10%

 

 

Power consumption

Approx. 5.4W

 

 

Pick-up system

RGB, 3CCD

 

 

Image sensor

1/3inch All pixels CCD

 

 

 

(Effective pixels Horizontal : 1034, Vertical : 779)

 

Scanning System

Progressive scan

 

 

Video output pixels

Horizontal pixels : 2048, Vertical : 1536

 

Pixel clock frequency

80.8736MHz

 

 

Sync signal frequency

Horizotal : 31.84KHz, Vertical : 20Hz

 

Sync system

Internal

 

 

Sensitivity

F8 standard (2000 lx, 3000K)

 

 

Minimum illumination

10 lx (F2.2, Sensitivity + 18 dB, 3000K)

 

Lens mount

C mount (flange back : 17.526 mm in-air)

 

Ambient temperature

32 to 104°F (0 to 40°C)

 

 

Ambient humidity

Less than 90%

 

 

Weight

Approx. 0.353lbs (160g)

 

 

External dimension

1.73” (W) x 1.73” (H) x 3.07” (D)

 

 

 

(44 (W) x 44 (H) x 78 (D) mm)

(except for protruded portion)

 

White balance

AWB (Automatic white balance), MANUAL (Manual)

 

Gain

MANUAL (Manual), OFF (0 dB)

 

 

Partial scanning

25fps, 30fps, 35fps, 40fps, 45fps, 50fps

 

Output signal

8-bit RGB, Digital output (Camera Link format)

 

Sync signal output

FVAL, LVAL, DVAL (Positive polarity)

 

 

Pixel Clock

 

 

External trigger input

CC1 (LVDS input), More than 2 s pulse width

 

Partial scanning control

CC2 (LVDS input)

 

 

signal input

 

 

 

Interface

Serial data interface : Ser TC (RXD), Ser TFG (TXD)

 

Optional parts

IK-TF9H (CAMERA HEAD) EXC-CL05S (Cable), etc

 

 

 

 

 

The designs and specifications are subject to change without notice.

32

Image 32
Contents IK-TF9U Following information is only for EU-member statesSafety Precautions Disclaimer Table of Contents Components Names and Functions Standard Connection Connector Pin AssignmentsConnection White Balance OperationAutomatic Black Balance Result displayed Meaning Temp LOWItems Controlled by Using on Screen Display Available selectionsMode Setting by on Screen Display Using the MenusMenus Shutter Electronic shutterFlicker may be large TRGChanging each setting in Manu mode Mode = ManualPartial scanning setting Menu UP, DownChanging the shutter speed setting Changing each setting in SS synchro. scan modeMode = SS Changing each setting in E.TRG mode Changing each setting in 1P SNR modeChanging the polarity of inputting trigger pulse setting Changing 1P SNR exposure time settingChanging each setting in 1P SR mode Mode = E.TRG E.TRG = 1P SRChanging 1P SR exposure time setting 1P SNR, 1P SR, PW SNR, PW SRChanging each setting in PW SNR mode Mode = E.TRG E.TRG = PW SNRMode = E.TRG E.TRG = RR Changing each setting in PW SR modeMode = E.TRG E.TRG = PW SR Gain Video gain Changing each setting in GainChanging the gain in Manu mode WHT BAL White balance MANU/OFF Changing gamma correctionChanging master pedestal Changing R pedestalSync OptionSetting by the frame Setting to factory setting statusSetting by 2H Synchro. Scan Operation1P SNR 1 Pulse Trigger Sync Non Reset 1 Pulse Trigger SYNC-NON Reset Picture Output TimingE. TRG External trigger Fval Lval Dval1P SR 1 Pulse Trigger Sync Reset 1 Pulse Trigger SYNC-RESET Picture Output TimingPW SNR Pulse width trigger SYNC-NON Reset Pulse Width Trigger SYNC-NON Reset Picture Output TimingPW SR Pulse width trigger SYNC-RESET 1 Pulse Width Trigger SYNC-RESET Picture Output TimingLong Term Exposure RR Reset restartInput Timing Chart Example When Partial Scanning Mode is on Partial ReadPartial Scanning OFF All pixels scanning Partial Scanning onExternal sync signal polarity Using the unit with external sync signalExternal Sync External sync frequency rangeOutput Waveform Timing Chart Horizontal Output Waveform Timing ChartVertical Output Waveform Timing Chart Fval LVAL、 DvalSpecifications RGB, 3CCDSymptom Items to be checked External Appearance DiagramBefore Making a Service Call Limited Warranty Toshiba CCD Camera One 1 Year Limited Warranty of Labor and PartsHow to Obtain Warranty Service Step-By-Step Procedures Your Responsibilities