1. Press the <Utility> button and scroll to Page 4 of the Utility menu using the <Page> knob. The display reads:

 

2

Prg Rcv Map:MIDI= User

 

￿msdB%kHz 2

msdB%kHz

 

1 msdB%kHz

 

 

 

 

 

 

 

 

3

4

1

 

LINK CHANGED

 

LINK CHANGED

 

LINK CHANGEDLINK CHANGED

 

 

 

WAH TUBE

EQ GATE

 

 

 

 

 

 

 

 

 

 

 

 

L/R OUTS

FACTORY USER

 

 

 

 

#

 

 

 

 

 

 

 

 

BANK

4 OF 16 b

 

 

 

 

 

 

 

 

 

 

 

 

PAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

L/R OUTS

2.Use the <3> knob to select the MIDI Preset change number you want mapped. Note that the number under Millennium USER changes along with the MIDI number.

3.Use the <4> knob to select the Millennium Preset you want the selected MIDI Preset change number to recall. As this number increases above Preset 100, note that Millennium USER changes to Millennium FACT, indicating that the mapped number will recall the indicated Preset number in the Factory bank..

Preset Transmit Map

With the Preset Transmit Map function, you can use your Millennium to send MIDI patch changes of your other effects devices. When you call up a preset in your Millennium, the appropriate presets in your other FX unit’s will also be recalled.

To remap a MIDI Preset change number to a preset number, do the following:

1.Press the <Utility> button,and scroll to Page 5 of the Utility menu using the <Page> knob. Now use the <1> knob and turn the setting to On. The display will now appear like this:

 

 

PrgTrans Map:User=MIDI

 

￿msdB%kHz

 

On msdB%kHz

 

1 msdB%kHz

 

 

1

 

 

2

3

4

 

2

LINK CHANGED

 

 

LINK CHANGED

 

LINK CHANGED

LINK CHANGED

 

 

 

WAH TUBE EQ

 

GATE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L/R OUTS

FACTORY USER

 

 

 

 

 

 

#

 

 

 

 

 

 

 

 

BANK

5 OF 16 b

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L/R OUTS

2.Use the <3> knob to select the Millennium preset number you want mapped. Note that the number under MIDI changes along with the preset number.

3.Use the <4> knob to select the MIDI preset change number to be sent out the MIDI Out port when the corresponding preset number is recalled.

SysEx Device Channel

An easy way to think of the System Exclusive Device channel option is to separate System Exclusive data from normal MIDI data. Each type of data has its own group of 16 channels upon which data can be transmitted. This feature will also allow individual remote control of more than one Millennium with SysEx commands.

From the Factory and in most situations, the SysEx channel is set at Channel 1.

User Guide

63

Image 71
Contents User’s Guide Mains Plug Warning Product Name Manufacturer’s Name8760 S. Sandy Parkway Sandy, Utah 84070, USAQuick Start Table of Contents Digital Effects Section Editing Modules Advanced TopicsAmplifier Section Midi FunctionsAppendix Using the Johnson Amplification J-12 Foot ControllerUser Guide Congratulations IntroductionUser Guide Front Panel Quick Tour of the Millennium Two-Fifty100 User Guide F FX Library Buttons Loop Send Jack This is the effects loop send jack Rear PanelFuse- 100, 120 VAC 6 Amp fuse is inserted here American Stack Dual Rectifier, Boogie MK II, Soldano SLO Amplifier Model TypesEffects include Programmable Mono FX Loop Basic SpecificationsJohnson Amplification J-12 foot controller Foot Controller CompatibilityModule Sizes Module TypesMaking Connections Setting UpXLR Cabinet Emulation functions To exit this mode, simply press the Preset buttonAssign Mode Preset ModeFX Edit Mode Utility ModeGetting Sounds Input and Master Output AdjustmentsGain Adjustments EQ and Preset LevelAmplifier Contour Control Wet/Dry Mix Adjustments Global or LocalAmplifier Model and Channel Selection Digital FX Quick Adjust Knobs Press the Utility button once. The display reads Selecting a PresetUsing the Tuner Utility Menu Tuner ModeReference and Output Johnson Amplification J-12 Tuner ModeInstant Tuner Access Press the any button to exit the Tuner modeNaming the Preset Naming and Storing PresetsAfter which you are taken to the preset you have just stored Storing the PresetIntegrated Amplifier Model Selection Editing a PresetPreset Editing Sections Integrated Amplifier Model EditingBgain LVL Adig LVL Analog Wah EditingAvail Link for Pedal 1 OFF Noise Gate EditingTo exit Noise gate edit mode, press the Preset button Selecting Effect Configuration RoutesChanging Effect Modules Selecting a DefaultAdjusting the Module’s Parameters Custom DefaultsComparing Original Pst Comparing ChangesNaming the Default Storing/Naming DefaultsEditing a Module Storing the DefaultOutput Module Functions Scrolling through a Module’s PagesEffect Name Digital Effect Module Size and TypeChoruses Default ListAnalog Wah Parameters Effects LibraryAnalog Wah Amplifier TypesNoise Gate Parameters Noise GateStereo Reverb a true stereo version of the Reverb Module Digital EffectsReverbs ReverbReverb Parameters Gated ReverbTime Over TypeOver Freq Low PassChoruses and Flangers Chorus T C HChorus Parameters Flanger Parameters FlangerPhaser Parameters PhasersOver Rotary Speaker SimulatorMode LevelTremolo & Auto Panner Parameters Tremolo and Auto-PannerTremolo Auto PannerPitch Shifters Parameters Pitch Shifters and HarmonyDetuners Dtn E -H DelaysDetuner Parameters Smear Delay ParametersDly Time TapItCompressor Parameters CompressorGraphic Equalizer Parameters EqualizersGraphic Equalizers Parametric Equalizer Parameters Multi Effects Modules Chorus/Delay and Flange/DelayParametric Equalizers Multi-Effect Module Parameters Whammy EffectsAuto Wah Effect Parameters Auto WahWhammy Effect Parameters LFOs Assigning ModifiersMidi CCs Dynamic ModifiersLinking a Parameter to a Modifier External Expression PedalsSetting up a Dynamic Modifier Setting up an LFOAmplifier Morphing Morphing Pedal AssignmentsMorphing Between Effect Modules Volume Pedal AssignmentsVol Pdl Morph Pdl Midi Merging Setting the Midi ChannelsPreset Receive Map Midi FunctionsSysEx Device Channel Preset Transmit MapSysex Dumps After which it returns to the Preset dump screenSysEx Dump Bulk System After which it returns to the User default screenGlobal vs. Local XLR Cabinet Emulation Factory ResetOther Utility Functions Footswitch Set-Up Output Mode and Speaker Cabinet Voicing SelectionsExpression Pedal Names Configuring the PedalboardConnecting the Johnson Amplification J-12 Foot Controller Assigning Functions Assigning Presets to FootswitchesPress the Preset button to exit Gain Exp 1 Min 56Max Assigning Parameters to Footswitches/ Expression PedalsJ12FCBank FS=Tog CCTran Other Footswitch FunctionsAssigning Midi Control to the Expression Pedals 12 will appear like this When connected. The display now readsTurn Page knob to page 3 and the display will read Momentary Footswitch AssignmentNaming Banks Bank Up/ Tuner and Bank Down / Bypass FootswitchesUsing the Tuner Other Pedalboard TidbitsWill now read Un-Linking or Viewing Parameter ControlMatchless Bank 1 TopBank 2 Fender Bank 4 VoxStudio Bank 12 Alternative Bank 18 DynamicsBank 13 Country Bank 19 Morph Bank 14 VintageBank 3 Boogie/Soldano Millennium Preset DescriptionsBank 6 Marshall Bank 5 MatchlessBank 8 Signature Bank 13 Country Bank 12 AlternativeBank 16 Jazz/Fusion Bank 15 StudioBank 18 Dynamics ConfigStereo 2,2 ConfigParall 4,4,2 ConfigMonoSplit 4,4,4,4 Effect Configuration ChartHarmony Interval Charts Audio Inputs Power Amp SectionPower Requirements Audio OutputsRemarks Midi Implementation ChartJohnson Amplification System Exclusive ImplementationMidi Basics General Format ProceduresSYSHEAD, 11h, F7h SYSHEAD, 49h, F7hSyshead 48h, dd1st1 dd1st2, ... ddnth1, ddnth2, F7h Ddn Bbs Vv = Software version number Rr =Tt = Syshead 17h, aa1, aa2,bbs1, bbs2, F7hNumber of available parameters in the FX Module Number of ModulesModules User requested Indicates the beginning of the xth ModuleSYSHEAD, 54h, cc, F7h 02h Effect Module 03h 04h Whole Effect ModuleYy= effect ID # SYSHEAD, 21h, F7hSYSHEAD, 22h, F7h SYSHEAD, 13h, yy1, yy2, zz1, zz2 F7hKey Label Hex equivalent SysEx Button/Keys/Footswitch codesFX Module Count for Module Types 00 FX Module Class Type SysEx Preset Dump ExampleFx Module codes and numbers PEQ 100 101 102 103 104 105 106 107