Johnson Millennium | Section - 7 Appendix |
When ww= 7F(h) | All module’s parameters will be requested. |
When ww= 68(h) | (position of the module minus 1), only that module’s parameters will be requested. |
ww | Requested Module’s parameter Values |
When a Request All Current Parameter Values procedure is received, the Millennium will respond with a Respond All Current Parameter Values procedure.
RECEIVE ALL CURRENT PARAMETER VALUES FOR CURRENT PRESET (24h)
SYS_HEAD, 24(h), nn1, nn2, ww1, ww2, mm1(1st), mm2(1st), aa1(1st), aa2(1st), dd1(1st)(1st), dd2(1st)1st, ... dd1(1st)(wth) ,dd2(1st)(wth),
... mm1(xth),...mm2(xth), aa1(xth), aa2(xth), dd1(xth)(1st), dd2(xth)(1st), ... dd1(xth)(wth),dd2(xth)(wth), F7(h)
When ww= 7F(h) | All module’s parameters will be received. |
When ww= 68(h) | (position of the modules minus 1), only that module’s parameters will be received. |
nn | Number of Modules. |
ww | Modules User requested. |
mm | Indicates the beginning of the xth Module. |
aa | Number of available parameters in the FX Module. |
dd | Current value for the wth parameter. |
The Receive All Current Parameter Values procedure is used to receive Parameter Values from the Millennium for the currently selected program.
Warning: Sending data that was retrieved from a different preset will delete the memory. Be sure to only send data that was received from the same preset.
REQUEST MODULE CONFIGURATION (25h)
SYS HEAD , 25 (h) , F7 (h)
When a Request Module Configuration procedure received, the Millennium will respond with a Respond Module Configuration procedure.
RESPOND MODULE CONFIGURATION (26h)
SYS HEAD , 26(h) , nn1, nn2, cc(1st)1,cc(1st)2, ee(1st)1, ee(1st)2, ... cc(nth)1, cc(nth)2 , ee(nth)1, ee(nth)2, F7(h)
nn | Number modules present in the algorithm |
cc | Class I.D. of the nth module in the algorithm |
ee | I.D. number of the effect currently loaded in the nth module (see pg. 12 for ID numbers) |
Class I.D. Numbers for millennium |
|
00(h) | Amplifier Type |
01(h) | 1/4 Effect Module |
User Guide