JVC GY-HD250 manual Presetting the Time Code from the LCD Screen, Presetting User’s Bit, Operation

Page 50

e_hd250.book Page 46 Tuesday, October 24, 2006 3:11 PM

PREPARATIONS FOR OPERATION

Presetting the Time Code from the LCD Screen

The time code can be preset directly from the LCD screen without opening the TC/UB/CLOCK menu screen.

CAUTION

PRESET mode is not available in the following.

TCG SOURCE item in the TC/UB/CLOCK menu screen is set to EXTERNAL.

TC GENE. switch is set to REGEN.

TC DUPLI. item in the TC/UB/CLOCK menu screen is set to ON.

Menu screen is displayed.

RECORDING mode is active.

Switching to CAM/VTR mode (When VTR indicator is blinking).

Blink

2.Press the USER2 button to reset all data.

Data becomes “00:00:00:00” and the hour digit starts blinking.

3.Set the time code (hour, minute, second and frame). The blinking digit can be set.

1Turn the SHUTTER dial to change the value of the blinking digit. Turn the SHUTTER dial up to increase the value and down to decrease the value.

Setting

„TC/UB/CLOCK menu screen

Set TCG SOURCE to INTERNAL.

Set framing of the time code generator in DROP FRAME. (When set to FRAME RATE 60/30)

Set to enable/disable user’s bit recording in UB REC. (When set to FRAME RATE 50/25)

„Set the TC GENE switch to REC or FREE.

MEMO

See page 44 for details on the above settings.

„Set the TC DISPLAY switch.

Set to TC to preset time code and UB to preset user’s bit.

2Press the SHUTTER dial to change the blinking digit.

3Repeat steps 1 and 2 and continue setting for each row.

4.Press the USER3 button to confirm the setting data.

• The LCD screen returns to the original screen.

Presetting User’s Bit

You can specify the user’s bit with a number or character between 0 - F.

CAUTION

All digits of user’s bit cannot be set to F.

If all digits are set to F and read, user’s bit is deemed as undefined during playback.

Operation

This section describes presetting of the time code.

 

 

USER 2 button

 

 

USER 1 button

USER 3 button

 

 

USER 1

USER 2 USER 3

 

 

 

SHUTTER

 

 

ND FILTER

SHUTTER dial

 

 

2

 

 

 

 

VF BRIGHT

1

 

 

 

 

USER 1

USER 2 USER 3

OFF

MENU

 

 

 

ND FILTER

 

 

 

2

 

 

STATUS button

1

 

 

 

MENU

 

 

 

STATUS

 

 

WHT.BAL

 

 

 

 

 

STATUS

ON

OFF

 

 

POWER

REC

 

 

1.In Standby or Stop mode, press the USER1 button for about 2 seconds while holding down the STATUS button.

The current time code generator data is displayed in enlarged display mode on the LCD screen. The hour digit starts blinking.

Aborting Preset Operation

While presetting, press the USER1 button while holding down the STATUS button.

Preset operation stops and the LCD screen returns to the original screen.

CAUTION

„Preset operation is terminated in the following.

TC DISPLAY switch is changed

CAM/VTR mode switch is changed

VTR operations are performed

„USER1, USER2, and USER3 presetting in the SWITCH MODE menus screen is not available when the Time Code Preset screen is displayed.

„The time code preset screen is displayed on the LCD screen or viewfinder. It will not be output from the VIDEO OUT terminal.

46

Image 50
Contents For Customer Use Victor Company of Japan, Limited LST0440-001BImportant Safeguards Safety Precautions RemarqueSafety Precautions Cont’d Port Cable LengthBusiness users Other Countries outside the European Union Information for Users on Disposal Old EquipmentEuropean Union HD251CHE Main Features Contents Playback Mode Precautions for Proper Use Head Cleaning Routine and Periodical MaintenancePrecautions for Use of Head Cleaning Tape Periodical MaintenanceBattery Pack to be Used Videocassette to be UsedCondensation occurs in the following cases Characteristic CCD Phe- nomenaCondensation Zoom Lens Th16 × 5.5BRMUFront Section 2PHONES Earphone jack Rear Section1Back tally lamp 3Shoulder belt hooksLCD Door Right Side Section ASTATUS Status/Menu button BGAIN Sensitivity selector switchCWHT.BAL White balance switch GHDV/DV LEDLeft Side Section EIEEE1394 IEEE1394 switch CGENLOCK/AUX in GENLOCK/AUX in switchDPBPR/TC PBPR/Time code switch GGENLOCK/AUX in GENLOCK/AUX in terminal BNCTop Section GFULL Auto Full auto shooting FAS switch DMONITOR Select Audio monitor selector switchFVTR VTR indicator LScrew holes for mounting accessoriesRecording and Image Out- put Formats Recording Composite RecordingIEEE1394 Indications on the LCD Monitor and in the View- finder Status ScreensStatus Screens in the Camera Mode Setting Status Contents of IndicationsContents Indications on the LCD Monitor and in the Viewfinder Cont’dTape time appears IDX Endura battery Voltage/remaining capacity %UB FF EE DD LCD/VF3/4 menu screen. X SeeFilter OFF ND1 CH-1O O O O O O O O O \ \ \CH-2O O O O O O O O O \ \ \ ND2Indication Indication Contents Video Format display Status Screen in VTR ModeHDV/DV input signal DoorNDF Magnified Status Indications on LCD MonitorEXT Safety Zone Indication Camera mode only Alarm Message DisplayMenu Setting Screen Center Mark OFF Switching between the LCD Screen and Viewfinder DisplaySafety Zone Basic System HZ-ZS13BAttaching the Microphone Provided How to Attach the View- finderAttaching the Zoom Lens Inserting an SD Memory Card Inserting an SD Memory CardTaking out the SD memory card About SD Memory CardsAttaching the Tripod Base Provided only for U model AC Operation Charging the Built-in BatteryHow to charge the built-in battery Removing the Battery Battery OperationAttaching the Battery „GY-HD250UOperating Time with Battery Pack Precautions for the Battery Opera- tionRemaining Battery Power Display Precautions for the Battery PackTurning the Power OFF Turning the Power onTurning the Power on Camera modeUnloading the Cassette Loading/Unloading the CassetteCassette Loading ModeSetting and Displaying the Date and Time Setting the Date and Time StyleDisplaying the Time and Date on the Screen Displaying Time Code Time code input entered the IEEE1394 connectorSetting Displayed Time Code/User’s BitDrop frame/Non-drop frame mode Presetting and Recording of Time CodeSetting DropZero-resetting the Time Code or User’s Bit Data Presetting time code dataPresetting user’s bit data Aborting Preset Operation Presetting the Time Code from the LCD ScreenPresetting User’s Bit OperationInternal About Time Code ModePlaying Back Time Code Slave unit GY-HD250U/GY-HD251E/GY-HD110U/GY- HD111E Settings and OperationsConnections Connection ExternalScreen Adjustment Viewfinder Adjustment Back Focus Adjustment Adjustment procedure White Balance AdjustmentWhite Balance Adjustment Error messagesWhite Shading Adjustment Setting the REC Item Setting the Video FormatSetting the Frame Rate Item ND Filter Camera SettingsScreen Size 43/169 Mode Selection Selecting the audio signal input Audio Input Signal Selec- tionSelecting the CH-2 channel input connector Adjusting Audio during RecordingMonitoring Audio during Recording LOW/MIDDLE/HIGHBasic Recording Opera- tion About the Focus Assist FunctionIf the Record-Standby Mode Contin- ues Header REC Function Record-Standby or Stop modeFunction/Initial Setting How to set the Header REC menu screen Executing the Header REC FunctionSearch Playback ProcedureFast-Forward, Rewind PB Audio CH DV Outputting AudioMIX Audio MonitorDisplaying Alarms Connecting the Video Signal CablesConnecting the IEEE1394 Cable Change 1394 SwitchRecording Composite Video Signals from an External Device Status Screen Display on the LCD Screen or ViewfinderAdjust SC and H Phase Using Genlock Func- tionsSynchronized Signals Dubbing with AV Devices HDV/DV Dubbing Videocassette you want to dubOFF Backup Recording SettingsShutter Speed in 24p Mode Connect a Remote Con- trol Unit RM-LP55/RM- LP57ALC+EEI Remote Control Unit Functions ListLolux Nega OFF/ON Shutter NormalMenu Screen Configura- tion Menu Screen Configuration Cont’d Setting Menu Screens TOP Menu Screen Video FORMAT1/2 Menu Screen Function/Setting bold characters indicate initial settingsSetting Description Letter Video FORMAT1/2 Menu Screen Cont’dNative Video FORMAT2/2 Menu Screen Terminal Setting B/P rInitial settings U model 7.5% E model 0.0% AutoMenu Screen 3200KMiddle HighNormal 108%Standard Stop RotationSkin Color DET Skin Color RangePreset White Balance Menu ScreenSwitch Mode Menu Screen REC Item Setting for Step Setting for Variable50dB AUDIO/MIC1/2 Menu Screen20dB 48KCH1/2 AUDIO/MIC2/2 Menu ScreenMIX Blue LCD/VF1/4 Menu Screen70-80% Image is displayed without inverting LCD Mirror ModeLCD/VF2/4 Menu Screen MirrorSEC LCD/VF3/4 Menu ScreenVoltage RGB LCD/VF4/4 Menu ScreenColor Drop TC/UB/CLOCK Menu ScreenInternal Disable Header REC Menu ScreenDATE+TIME TIME/DATE Menu ScreenBARS+CAM Variation Range U model MM/DD/YY E model DD/MM/YYBlink OTHERS1/2 Menu Screen3MIN OTHERS2/2 Menu Screen 1394DR-HD100 A.OFF Menu ALL ResetOTHERS2/2 Menu Screen Cont’d Drum HourGenlock Menu Screen SD H Phase *1HD H Phase SC Coarse *1File Manage Menu Screen Loading a menu settings file100 Displaying the File Manage menu screen101 Saving settingsError displays 102 Initializing formatting an SD mem- ory card103 How to Use Skin DetailSetting the skin detail function color and range 104 How to Use Skin Detail Cont’dUsing the Skin Detail Function Outputs multi-format color bars 105Outputting Color Bars 106 Display Status Action107 Error Code Error Details GY-HD250/GY-HD251 Remedy Operation 108Viewfinder Screen Blinking Pattern Remaining Battery/Tape109 Sound interrupted once per second110 TroubleshootingSymptoms Remedy RGB?How to Display the Hour Meter 111Specifications 112Excluding the CHU/CHE model External Dimensions unit mm113
Related manuals
Manual 12 pages 39.42 Kb