Axis Communications Q1931E PT Controls on the Live View, Click Use Https, Manual Trigger

Page 9

AXIS Q1931–E PT Mount Thermal Network Camera

Access the Product

The default administrator user name root is permanent and cannot be deleted. If the password for root is lost, the product must be reset to the factory default settings. See Reset to Factory Default Settings on page 48.

To set the password via a standard HTTP connection, enter it directly in the dialog.

To set the password via an encrypted HTTPS connection, follow these steps:

1.Click Use HTTPS.

A temporary certificate (valid for one year) is created, enabling encryption of all traffic to and from the product, and the password can now be set securely.

2.Enter a password and then re-enter it to confirm the spelling.

3.Click OK. The password has now been configured.

The Live View Page

The controls and layout of the Live View page may have been customized to meet specific installation requirements and user preferences. Consequently, some of the examples and functions featured here may differ from those displayed in your own Live View page. The following provides an overview of each available control.

Controls on the Live View Page

Select a stream profile for the Live View page from the Stream Profile drop-down list. For information about how to configure stream profiles, see page 16.

The Palette drop-down list allows you to apply a palette to the image. See Image on page 15

The Manual Trigger button is used to trigger an action rule from the Live View page. For information about how to configure and enable the button, see Manual Trigger on page 9 .

Click Snapshot to save a snapshot of the video image. This button is primarily intended for use when the

AXIS Media Control viewer toolbar is not available. Enable this button from Live View Config > Action Buttons.

Activate the product’s heater with this button. Enable this button from Live View Config > Action Buttons.

Manual Trigger

The Manual Trigger is used to trigger an action rule from the Live View page. The manual trigger can for example be used to validate actions during product installation and configuration.

To configure the manual trigger:

1.Go to Setup > Events.

2.Click Add to add a new action rule.

3.From the Trigger drop-down list, select Input Signal.

4.From the second drop-down list, select Manual Trigger.

5.Select the desired action and configure the other settings as required.

9

Image 9
Contents Axis Q1931-E PT Mount Thermal Network Camera Legal Considerations About this documentLiability Intellectual Property RightsLearn More SupportAxis Q1931-E PT Mount Thermal Network Camera Table of ContentsConnectors Performance Considerations Network Connector Connectors and ButtonsFor technical specifications, see RJ45 Ethernet connector with Power over Ethernet PoEPower Connector LED IndicatorsRS485/RS422 Connector SD Card SlotAccess from a Browser Access the ProductAccess from the Internet Set the Root PasswordLive View Go to Setup EventsControls on the Live View Click Use HttpsPTZ Controls Axis Media Control viewer toolbarHow to Stream H.264 Media StreamsAxis Media Control AMC QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamAxis Q1931-E PT Mount Thermal Network Camera Basic Setup Set Up the ProductVideo Stream VideoPixel Counter Image264 Stream ProfilesExposure Settings Camera SettingsOverlay Image AppearanceOverlay Image Use Overlay Text in an Action RuleGo to Video Overlay Image Under Overlay Settings, select Include text Privacy MaskGo to Events Action Rules Default Viewer for Browsers Configure the Live ViewViewer Settings Browser Viewer DescriptionUser Defined Links Go to PTZ Preset Positions Preset PositionsPTZ Pan Tilt Zoom Guard TourDevice Settings Install PTZ DriverAdvanced Control QueueAxis Q1931-E PT Mount Thermal Network Camera Detectors Set Up Motion Detection WindowsShock Detection Motion DetectionParameter Object Size History Sensitivity High level 100% Default valuesLow level 0% DetectionGo to Setup Applications Install ApplicationApplications Application LicensesInstall Axis Application Configure Axis Cross Line DetectionAxis Cross Line Detection Axis Video Motion Detection Configure Axis Video Motion DetectionAxis Q1931-E PT Mount Thermal Network Camera Events Setting Up an Action RuleTriggers Go to Events Action Rules and click AddActions Add Recipients Setting Up an Email RecipientPTZ Control Go to Events Recipients and click AddRecurrences SchedulesTo create a new schedule Go to Events Schedules and click AddRecording List RecordingsContinuous Recording Go to Recordings ListLanguages System Options To log in again and be configured to use this functionalitySecurity UsersIeee Go to Setup System Options Security CertificatesCertificates Go to System Options Security IeeeClick Install certificate and upload the certificate Basic TCP/IP SettingsIPv4 Address Configuration Date & TimeAssign IP Address Using ARP/Ping IPv6 Address ConfigurationARP/Ping Linux/Unix syntaxAdvanced TCP/IP Settings Select Use the host name to set the host name manually Link-Local IPv4 AddressNAT traversal port mapping for IPv4 Smtp email QoS Quality of ServiceUPnPTM StorageRTP/H.264 BonjourMount and Unmount SD Card Network ShareFormat SD Card To add a network sharePorts & Devices MaintenanceCOM Port See the online helpSupport Overview SupportSystem Overview Logs & ReportsReset to Factory Default Settings Plain ConfigFile Upload Upgrade the Firmware TroubleshootingEmergency Recovery Procedure Check the FirmwareProblems setting the IP address Symptoms, Possible Causes and Remedial ActionsProduct cannot be accessed from a browser Product is accessible locally but not externallyVideo and image problems, general Problems with streaming H.264Video Camera Settings Storage and disk management problemsVideo cannot be recorded Technical Specifications Resolutions Function/group Specifications VideoImage settings InstallationPower Function/group Specifications General CasingConnectors WeightRS485/422 Connector ConnectorsPerformance Considerations M1.10