Axis Communications Q1931E PT Ports & Devices, Maintenance, COM Port, See the online help

Page 46

AXIS Q1931–E PT Mount Thermal Network Camera

System Options

4.Enter the name of the share in the Share field. Sub folders cannot be used.

5.If required, select The share requires login and enter the user name and password.

6.Click Connect.

To clear all recordings and data from the Axis product’s folder on the designated share, click Clear under Storage Tools.

To avoid filling the share, it is recommended to remove recordings continuously. Under Recording Settings, select Remove recordings older than and select the number of days or weeks.

To stop writing to the share and protect recordings from being removed, select Lock under Recording Settings.

Ports & Devices

COM Port

The Axis product has one RS-485/RS-422 serial port. The port supports the following modes:

Generic HTTP allows the Axis product to receive data and send commands via HTTP.

Pan Tilt Zoom is used to control a PTZ device. The PTZ device requires a driver. See Install PTZ Driver for more information. Drivers can be downloaded from www.axis.com

Generic TCP/IPallows the Axis product to receive data and send commands via TCP/IP. Daisy chain server - Allows Daisy chain clients to communicate with the Axis product.

Select the desired Port Type from the drop-down list. For more information on Serial Port Settings and Daisy Chain Port Settings

see the online help .

Maintenance

The Axis product provides several maintenance functions. These are available under System Options > Maintenance.

Click Restart to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current settings.

Note

A restart clears all entries in the Server Report.

Click Restore to reset most settings to the factory default values. The following settings are not affected:

the boot protocol (DHCP or static)

the static IP address

the default router

the subnet mask

the system time

the IEEE 802.1X settings

uploaded applications are kept but must be restarted

Click Default to reset all settings, including the IP address, to the factory default values. This button should be used with caution. The Axis product can also be reset to factory default using the control button, see Reset to Factory Default Settings on page 48.

For information about firmware upgrade, see Upgrade the Firmware on page 49.

46

Image 46
Contents Axis Q1931-E PT Mount Thermal Network Camera Liability About this documentLegal Considerations Intellectual Property RightsSupport Learn MoreTable of Contents Axis Q1931-E PT Mount Thermal Network CameraConnectors Performance Considerations For technical specifications, see Connectors and ButtonsNetwork Connector RJ45 Ethernet connector with Power over Ethernet PoERS485/RS422 Connector LED IndicatorsPower Connector SD Card SlotAccess from the Internet Access the ProductAccess from a Browser Set the Root PasswordControls on the Live View Go to Setup EventsLive View Click Use HttpsAxis Media Control viewer toolbar PTZ ControlsMedia Streams How to Stream H.264Axis Media Control AMC Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAxis Q1931-E PT Mount Thermal Network Camera Set Up the Product Basic SetupPixel Counter VideoVideo Stream ImageStream Profiles 264Overlay Camera SettingsExposure Settings Image AppearanceUse Overlay Text in an Action Rule Overlay ImageGo to Video Overlay Image Privacy Mask Under Overlay Settings, select Include textGo to Events Action Rules Viewer Settings Configure the Live ViewDefault Viewer for Browsers Browser Viewer DescriptionUser Defined Links PTZ Pan Tilt Zoom Preset PositionsGo to PTZ Preset Positions Guard TourAdvanced Install PTZ DriverDevice Settings Control QueueAxis Q1931-E PT Mount Thermal Network Camera Shock Detection Set Up Motion Detection WindowsDetectors Motion DetectionLow level 0% Default valuesParameter Object Size History Sensitivity High level 100% DetectionApplications Install ApplicationGo to Setup Applications Application LicensesConfigure Axis Cross Line Detection Install Axis ApplicationAxis Cross Line Detection Configure Axis Video Motion Detection Axis Video Motion DetectionAxis Q1931-E PT Mount Thermal Network Camera Triggers Setting Up an Action RuleEvents Go to Events Action Rules and click AddActions PTZ Control Setting Up an Email RecipientAdd Recipients Go to Events Recipients and click AddTo create a new schedule SchedulesRecurrences Go to Events Schedules and click AddContinuous Recording RecordingsRecording List Go to Recordings ListLanguages Security To log in again and be configured to use this functionalitySystem Options UsersCertificates Go to Setup System Options Security CertificatesIeee Go to System Options Security IeeeIPv4 Address Configuration Basic TCP/IP SettingsClick Install certificate and upload the certificate Date & TimeARP/Ping IPv6 Address ConfigurationAssign IP Address Using ARP/Ping Linux/Unix syntaxAdvanced TCP/IP Settings Link-Local IPv4 Address Select Use the host name to set the host name manuallyNAT traversal port mapping for IPv4 QoS Quality of Service Smtp emailRTP/H.264 StorageUPnPTM BonjourFormat SD Card Network ShareMount and Unmount SD Card To add a network shareCOM Port MaintenancePorts & Devices See the online helpSystem Overview SupportSupport Overview Logs & ReportsPlain Config Reset to Factory Default SettingsFile Upload Emergency Recovery Procedure TroubleshootingUpgrade the Firmware Check the FirmwareProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product is accessible locally but not externallyVideo Camera Settings Problems with streaming H.264Video and image problems, general Storage and disk management problemsVideo cannot be recorded Technical Specifications Image settings Function/group Specifications VideoResolutions InstallationConnectors Function/group Specifications General CasingPower WeightConnectors RS485/422 ConnectorPerformance Considerations M1.10