Axis Communications Q1931E PT user manual Configure the Live View, Default Viewer for Browsers

Page 20

AXIS Q1931–E PT Mount Thermal Network Camera

Configure the Live View Page

Configure the Live View Page

You can customize the Live View page and alter it to suit your requirements. It is possible to define the following features of the Live View page.

Stream Profile. See page 16.

Default Viewer for Browser. See page 20.

Viewer Settings. See page 20.

Action Buttons. These are the buttons described in Controls on the Live View Page on page 9 .

User Defined Links. See page 21.

Default Viewer for Browsers

From Live View Config > Default Viewer select the default method for viewing video images in your browser. The product attempts to show the video images in the selected video format and viewer. If this is not possible, the product overrides the settings and selects the best available combination.

Browser

Viewer

Description

 

 

 

Windows Internet Explorer

AMC

Recommended viewer in Internet Explorer (H.264/Motion JPEG).

 

 

 

 

QuickTime

H.264.

 

 

 

 

Java applet

A slower imaging alternative to AMC (Motion JPEG). Requires one of the

 

 

following installed on the client:

 

 

• JVM (J2SE) 1.4.2 or higher.

 

 

• JRE (J2SE) 5.0 or higher.

 

 

 

 

Still image

Displays still images only. Click the Refresh button in your browser to view a

 

 

new image.

 

 

 

Other browsers

Server Push

Recommended viewer for other browsers (Motion JPEG).

 

 

 

 

QuickTime

H.264.

 

 

 

 

Java applet

A slower imaging alternative to Server Push (Motion JPEG only).

 

 

 

 

Still image

Displays still images only. Click the Refresh button in your browser to view a

 

 

new image.

 

 

 

For more information, please see the online help .

Viewer Settings

To configure options for the viewer, go to Live View Config > Viewer Settings.

Select Show viewer toolbar to display the AXIS Media Control (AMC) or the QuickTime viewer toolbar under the video image in your browser.

H.264 decoder installation. The administrator can disable installation of the H.264 decoder included with AXIS Media Control. This is used to prevent installation of unlicensed copies. Further decoder licenses can be purchased from your Axis reseller.

Select Enable recording button to enable recording from the Live View page. This button is available when using the AMC viewer. The recordings are saved to the location specified in the AMC Control Panel. See AXIS Media Control (AMC) on page 11 .

20

Image 20
Contents Axis Q1931-E PT Mount Thermal Network Camera About this document Legal ConsiderationsLiability Intellectual Property RightsSupport Learn MoreTable of Contents Axis Q1931-E PT Mount Thermal Network CameraConnectors Performance Considerations Connectors and Buttons Network ConnectorFor technical specifications, see RJ45 Ethernet connector with Power over Ethernet PoELED Indicators Power ConnectorRS485/RS422 Connector SD Card SlotAccess the Product Access from a BrowserAccess from the Internet Set the Root PasswordGo to Setup Events Live ViewControls on the Live View Click Use HttpsAxis Media Control viewer toolbar PTZ ControlsAxis Media Control AMC How to Stream H.264Media Streams Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAxis Q1931-E PT Mount Thermal Network Camera Set Up the Product Basic SetupVideo Video StreamPixel Counter ImageStream Profiles 264Camera Settings Exposure SettingsOverlay Image AppearanceGo to Video Overlay Image Overlay ImageUse Overlay Text in an Action Rule Go to Events Action Rules Under Overlay Settings, select Include textPrivacy Mask Configure the Live View Default Viewer for BrowsersViewer Settings Browser Viewer DescriptionUser Defined Links Preset Positions Go to PTZ Preset PositionsPTZ Pan Tilt Zoom Guard TourInstall PTZ Driver Device SettingsAdvanced Control QueueAxis Q1931-E PT Mount Thermal Network Camera Set Up Motion Detection Windows DetectorsShock Detection Motion DetectionDefault values Parameter Object Size History Sensitivity High level 100%Low level 0% DetectionInstall Application Go to Setup ApplicationsApplications Application LicensesAxis Cross Line Detection Install Axis ApplicationConfigure Axis Cross Line Detection Configure Axis Video Motion Detection Axis Video Motion DetectionAxis Q1931-E PT Mount Thermal Network Camera Setting Up an Action Rule EventsTriggers Go to Events Action Rules and click AddActions Setting Up an Email Recipient Add RecipientsPTZ Control Go to Events Recipients and click AddSchedules RecurrencesTo create a new schedule Go to Events Schedules and click AddRecordings Recording ListContinuous Recording Go to Recordings ListLanguages To log in again and be configured to use this functionality System OptionsSecurity UsersGo to Setup System Options Security Certificates IeeeCertificates Go to System Options Security IeeeBasic TCP/IP Settings Click Install certificate and upload the certificateIPv4 Address Configuration Date & TimeIPv6 Address Configuration Assign IP Address Using ARP/PingARP/Ping Linux/Unix syntaxAdvanced TCP/IP Settings NAT traversal port mapping for IPv4 Select Use the host name to set the host name manuallyLink-Local IPv4 Address QoS Quality of Service Smtp emailStorage UPnPTMRTP/H.264 BonjourNetwork Share Mount and Unmount SD CardFormat SD Card To add a network shareMaintenance Ports & DevicesCOM Port See the online helpSupport Support OverviewSystem Overview Logs & ReportsFile Upload Reset to Factory Default SettingsPlain Config Troubleshooting Upgrade the FirmwareEmergency Recovery Procedure Check the FirmwareSymptoms, Possible Causes and Remedial Actions Problems setting the IP addressProduct cannot be accessed from a browser Product is accessible locally but not externallyProblems with streaming H.264 Video and image problems, generalVideo Camera Settings Storage and disk management problemsVideo cannot be recorded Technical Specifications Function/group Specifications Video ResolutionsImage settings InstallationFunction/group Specifications General Casing PowerConnectors WeightConnectors RS485/422 ConnectorPerformance Considerations M1.10