AutoDome 700 Series IP PTZ Camera | Configuring the AutoDome 700 Series en 41 |
|
|
4.33Recording Profiles
You can define up to ten different recording profiles. You will then use these recording profiles in the recording scheduler, where they are linked with the individual days and times (see Section 4.35 Recording Schedule, page 42).
NOTICE!
You can change or add to the recording profile description on the tabs on the Recording Scheduler page (see Page 42).
1.Click one of the tabs to edit the corresponding profile.
2.If necessary, click the Default button to return all settings to their default values.
3.Click the Copy Settings button if you want to copy the currently visible settings to other profiles. A new window will open and you can select the profiles in which you want to copy the settings.
4.For each profile, click the Set button to save the settings in the unit.
Standard recording
Here you can select the mode for standard recordings.
If you select Continuous, the recording proceeds continuously. If the maximum memory capacity is reached, older recordings will automatically be overwritten. If you select the Pre- alarm option, recording will only take place in the
If you select Off, no automatic recording takes place.
CAUTION!
You can specify limitations for overwriting older recordings in Continuous mode by configuring the retention time (see Section 4.34 Retention Time, page 42).
Standard profile
From this field, you can select the encoder profile to be used for recording (see
Section 4.19 Encoder Profile, page 28).
NOTICE!
The recording profile can deviate from the standard setting Active profile and is only used during an active recording.
You can select the required
You can select the required
Post-alarm profile
You can select the encoder profile to be used for recording during the
The Standard profile option adopts the selection at the top of the page.
Alarm input / Motion alarm / Video loss alarm
Here you can select the alarm sensor that is to trigger a recording.
Bosch Security Systems, Inc. | User Manual | F.01U.215.777 1.0 2011.07 |