62 en Troubleshooting GuideAutoDome 700 Series IP PTZ Camera
Problem | Solution |
|
|
| |
No Audio | – Check the computer receiving the audio from the VG5 AutoDome or from the IP | |
| Encoder. | |
| – | Check the computer’s audio settings. Ensure that the sound levels are at an audible |
|
| level. |
| – | Check the computer’s audio output card and speakers. Play a secondary source of |
|
| audio on the computer. If you still do not hear audio replace the speakers and try |
|
| again. |
|
| |
| If O.K., then: | |
| – Ensure that the Audio option is enabled for the IP device. | |
| a. | Access the Settings Web page for the |
| b. | Expand the Encoder Settings link, then click Audio Settings. |
| c. | Ensure that On is selected from the Enable Audio |
|
| |
| If O.K., then: | |
| – Check the microphone. | |
| Connect appropriate speakers directly to the microphone at the camera site and | |
| confirm that the audio is clear and audible at the location. | |
| An audio problem or noise at the source will further degrade as it travels through all the | |
| cables and connections. | |
|
| |
| If O.K., then: | |
| – Verify the cable type and installation used for audio connections between the | |
| microphone and the VG5 AutoDome. | |
| – | Cable type: Coaxial |
| – | Cable length: 10 m (33 ft), maximum |
|
| Refer to the VG5 AutoDome Installation Manual for more information. |
|
|
|
F.01U.215.777 1.0 2011.07 | User Manual | Bosch Security Systems, Inc. |