Page 31

AutoDome 700 Series IP PTZ Camera

Configuring the AutoDome 700 Series en 31

 

 

P-frame Quality

This setting allows you to adjust the maximum image quality of the P-frames. The basic setting Auto automatically adjusts to the optimum combination of movement and image definition (focus). Alternatively, you can use the slide control to set a value between 9and51. The value 9 represents the best image quality with, if necessary, a lower frame refresh rate depending on the settings for the maximum data rate. A value of 51 results in a very high refresh rate and lower image quality.

Default

Click Default to return the profile to the factory default values.

4.20Encoder Streams

Select the property and default profile for each H.264 stream and set the parameters for the M-JPEG stream.

H.264 BP+ bit-rate-limited

Select this setting when using hardware decoders. The bit rate is limited to 1.2 Mbps. CABAC: off

CAVLC: on

GOP structure: IP

I-frame distance: 15

Deblocking filter: on

H.264 MP SD

Select this setting when using software decoders, PTZ and for rapid movements in the images.

CABAC: on

CAVLC: off

GOP structure: IP

I-frame distance: 30

Deblocking filter: on

To select the stream options:

1.Select the required encoder properties and one of the encoder profiles for each data stream.

2.Click the Preview button. The preview screens for both data streams are shown.

3.Click the 1:1 Live View button below the preview screen to open a new window with the original data stream and to check the image quality and the transmission rate.

Property

Select one of the H.264 standards for each stream.

Default profile

Select one of the following profiles for each stream:

High resolution 1

High resolution 2

Low bandwidth

DSL

ISDN (2B)

ISDN (1B)

Modem

GSM

Refer to Section 4.19 Encoder Profile, page 28, for more details about each stream.

Bosch Security Systems, Inc.

User Manual

F.01U.215.777 1.0 2011.07

Image 31
Contents AutoDome 700 Series IP PTZ Camera Page Table of Contents User Command Table Index Troubleshooting GuideSeconds and ends with a firmware version screen Powering OnGetting Started Establishing AutoDome ControlOverview of Features Using the AutoDome 700 SeriesSystem Requirements Installation manual Connecting the AutoDome 700 Series to the PCUsing the Configuration Manager Configuring the AutoDome 700 Series CameraNetwork Settings Using the AutoDome 700 Series Web ServerDisplay Stamping 5The LivepageMaximum Number of Connections View Control Protected AutoDome 700 SeriesProtected Network Image SelectionTriggering Relay Digital I/OSystem Log / Event Log Aux Control Tab To Enter a Keyboard Control CommandTo Set a Preset Shot To View a Preset ShotProcessor Load Image ResolutionSaving Snapshots Recording Video SequencesVG5 Audio Connections Audio Line Input SpecificationsContact Description Activating Audio Reception Enabling Audio Transmission Making Changes Configuring the AutoDome 700 SeriesStarting Configuration NavigationBasic Mode Date/Time Basic Mode Device AccessBasic Mode Network Page Advanced Mode General Basic Mode AudioBasic Mode Recording Basic Mode System OverviewInitiator extension PasswordDevice time zone Date/TimeDate format Device date/Device timeDisplay Stamping Advanced Mode Web Interface Appearance Livepage Functions Logging Advanced Mode Camera Installer MenuEncoder Profile Bosch Security Systems, Inc 01U.215.777 1.0 Target data rate Video resolutionExpert Settings Profile nameEncoder Streams Preview Privacy MasksJpeg stream Camera Settings Shutter High Sensitivity Setting StabilizationNight Mode Night Mode ThresholdLens Settings Diagnostics PTZ SettingsTo define and edit an individual scene Preposition and ToursTo define a preposition tour Audio SectorsMiscellaneous LogsAdvanced Mode Recording Storage Management Deactivating Storage Media Formatting Storage MediaRecording Profiles Recording includes Virtual alarmRetention Time Recording ScheduleRecording Status Number of destination IP address Advanced Mode Alarm Alarm ConnectionsConnect on alarm Destination passwordDecoder Video transmissionRemote port Video outputVCA Profiles VCA configurationAlarm status 39 VCASelect Area MOTION+ only Motion detector MOTION+ onlySensitivity MOTION+ only Minimum object size MOTION+ onlyGlobal change Trigger delay sTamper detection SensitivityAudio Alarm Alarm E-Mail Alarm Rules Alarm Task EditorAdvanced Mode Network Network Access Advanced Mode Interfaces Alarm InputsRelay Https browser port Automatic IP assignmentDNS server address Http browser portTelnet support Interface mode ETHEnable DynDNS RCP+ portAdvanced TCP Metadata Port EnableMulticast UPnPFTP Posting Encryption Advanced Mode Service MaintenanceFirmware Download LicensesSystem Overview UploadVG5 AutoDome Operation and Control Troubleshooting GuideIf O.K., then If using a non-Bosch power supply If O.K., then If there is power to the AutoDome, thenConnection Problem Solution No NetworkVG5 700 Series AutoDome Video and Control 3VG5 Series AutoDome AudioProblem Solution No Audio Poor Audio Problem Solution If O.K., thenUser Command Table Index SymbolsJpeg Vidos Page Page Page Page Page Page Bosch Security Systems, Inc