Bosch Appliances VG5 700 series user manual Configuring the AutoDome 700 Series Camera

Page 8

8

en Using the AutoDome 700 Series

AutoDome 700 Series IP PTZ Camera

 

 

 

NOTICE!

You can also use the Bosch Video Client utility to configure the network settings for an AutoDome 700 Series camera. Go to www.boschsecurity.com to download the Configuration Manager software and Operating Manual.

2.4

Configuring the AutoDome 700 Series Camera

To operate the camera in your network you must assign it a valid network IP address. The default IP address is 192.168.0.1, but you may have to change this address if it conflicts with another device on your network. Refer to Section 4.3 Basic Mode: Network, page 20 for more information.

To properly configure the camera for your network, you need the following information:

Unit IP address: An identifier for the camera on a TCP/IP network. For example, 140.10.2.110 is a valid syntax for an IP address.

Subnet mask: A mask used to determine what subnet an IP address belongs to.

Gateway IP address: A node on a network that serves as an entrance to another network.

Port: An endpoint to a logical connection in TCP/IP and UDP networks. The port number identifies the use of the port for use through a firewall connection.

NOTICE!

Ensure that the network parameters of your cameras are available before you begin configuration.

The AutoDome 700 Series defaults are as follows:

IP Address: 192.168.0.1

Subnet Mask: 255.255.255.0

Gateway IP Address: 0.0.0.0

The following sections provide instructions about installing the software necessary to view images over an IP connection, configuring the IP network settings and accessing the AutoDome 700 Series images from a Web browser.

2.4.1Changing the Network Settings

The AutoDome 700 Series has a default IP address of 192.168.0.1. To change the IP address or any network settings, you can use the Configuration Manager software or the AutoDome 700 Series server.

NOTICE!

Contact your local network administrator for a valid IP address, Subnet Mask, and a Gateway IP Address.

Using the Configuration Manager

Configuration Manager is an optional network utility provided on the Bosch Security Systems Web site. Use the Configuration Manager Manual to make any configuration changes.

NOTICE!

Depending on the PC network security settings, the user may have to add the new IP address to the browser’s trusted sites list for the IP AutoDome controls to operate.

F.01U.215.777 1.0 2011.07

User Manual

Bosch Security Systems, Inc.

Image 8
Contents AutoDome 700 Series IP PTZ Camera Page Table of Contents Troubleshooting Guide User Command Table IndexPowering On Getting StartedEstablishing AutoDome Control Seconds and ends with a firmware version screenSystem Requirements Using the AutoDome 700 SeriesOverview of Features Connecting the AutoDome 700 Series to the PC Installation manualConfiguring the AutoDome 700 Series Camera Using the Configuration ManagerUsing the AutoDome 700 Series Web Server Network SettingsMaximum Number of Connections 5The LivepageDisplay Stamping Protected AutoDome 700 Series Protected NetworkImage Selection View ControlSystem Log / Event Log Digital I/OTriggering Relay To Enter a Keyboard Control Command To Set a Preset ShotTo View a Preset Shot Aux Control TabImage Resolution Saving SnapshotsRecording Video Sequences Processor LoadContact Description Audio Line Input SpecificationsVG5 Audio Connections Activating Audio Reception Enabling Audio Transmission Configuring the AutoDome 700 Series Starting ConfigurationNavigation Making ChangesBasic Mode Device Access Basic Mode Date/TimeBasic Mode Network Page Basic Mode Audio Basic Mode RecordingBasic Mode System Overview Advanced Mode GeneralPassword Initiator extensionDate/Time Date formatDevice date/Device time Device time zoneDisplay Stamping Advanced Mode Web Interface Appearance Livepage Functions Encoder Profile Advanced Mode Camera Installer MenuLogging Bosch Security Systems, Inc 01U.215.777 1.0 Video resolution Expert SettingsProfile name Target data rateEncoder Streams Jpeg stream Privacy MasksPreview Camera Settings High Sensitivity Setting Stabilization Night ModeNight Mode Threshold ShutterLens Settings PTZ Settings DiagnosticsTo define a preposition tour Preposition and ToursTo define and edit an individual scene Sectors MiscellaneousLogs AudioAdvanced Mode Recording Storage Management Formatting Storage Media Deactivating Storage MediaRecording Profiles Virtual alarm Retention TimeRecording Schedule Recording includesRecording Status Advanced Mode Alarm Alarm Connections Connect on alarmDestination password Number of destination IP addressVideo transmission Remote portVideo output DecoderVCA configuration Alarm status39 VCA VCA ProfilesMotion detector MOTION+ only Sensitivity MOTION+ onlyMinimum object size MOTION+ only Select Area MOTION+ onlyTrigger delay s Tamper detectionSensitivity Global changeAudio Alarm Alarm E-Mail Alarm Task Editor Alarm RulesRelay Advanced Mode Interfaces Alarm InputsAdvanced Mode Network Network Access Automatic IP assignment DNS server addressHttp browser port Https browser portInterface mode ETH Enable DynDNSRCP+ port Telnet supportAdvanced Enable MulticastUPnP TCP Metadata PortFTP Posting Firmware Advanced Mode Service MaintenanceEncryption Licenses System OverviewUpload DownloadTroubleshooting Guide If O.K., then If using a non-Bosch power supplyIf O.K., then If there is power to the AutoDome, then VG5 AutoDome Operation and ControlProblem Solution No Network VG5 700 Series AutoDome Video and Control3VG5 Series AutoDome Audio ConnectionProblem Solution No Audio Problem Solution If O.K., then Poor AudioUser Command Table Symbols IndexJpeg Vidos Page Page Page Page Page Page Bosch Security Systems, Inc