54 en Configuring the AutoDome 700 Series

AutoDome 700 Series IP PTZ Camera

 

 

You can activate and configure encryption of the media data (video and metadata) on the Encryption page (see Section 4.52 Encryption, page 58).

RCP+ port 1756

To exchange connection data, you can activate the unsecured RCP+ port 1756. If you want connection data to be transmitted only when encrypted, select the Off option to deactivate the port.

Telnet support

If you want to allow only secure connections with encrypted data transmission, you must select the Off option to deactivate Telnet support. The unit will then no longer be accessible using the Telnet protocol.

Interface mode ETH

If necessary, select the Ethernet link type for the ETH interface. Depending on the unit connected, it may be necessary to select a special operation type.

Network MSS (Byte)

You can set the maximum segment size for the IP packet's user data. This gives you the option to adjust the size of the data packets to the network environment and to optimize data transmission. Please comply with the MTU value of 1,514 bytes in UDP mode.

iSCSI MSS (Byte)

You can specify a higher MSS value for a connection to the iSCSI system than for the other data traffic via the network. The potential value depends on the network structure. A higher value is only useful if the iSCSI system is located in the same subnet as the AutoDome 700 Series.

Enable DynDNS

DynDNS.org is a DNS hosting service that stores IP addresses in a database ready for use. It allows you to select the AutoDome 700 Series via the Internet using a host name, without having to know the current IP address of the unit. You can enable this service here. To do this, you must have an account with DynDNS.org and you must have registered the required host name for the unit on that site.

NOTICE!

Information about the service, registration process and available host names can be found at DynDNS.org.

Host name

Enter the host name registered on DynDNS.org for the AutoDome 700 Series here.

User name

Enter the user name you registered at DynDNS.org here.

Password

Enter the password you registered at DynDNS.org here.

Force registration now

You can force the registration by transferring the IP address to the DynDNS server. Entries that change frequently are not provided in the Domain Name System. It is a good idea to force the registration when you are setting up the device for the first time. Only use this function when necessary and no more than once a day, to avoid the possibility of being blocked by the service provider. To transfer the IP address of the AutoDome 700 Series, click the Register button.

F.01U.215.777 1.0 2011.07

User Manual

Bosch Security Systems, Inc.

Image 54
Contents AutoDome 700 Series IP PTZ Camera Page Table of Contents Troubleshooting Guide User Command Table IndexEstablishing AutoDome Control Powering OnGetting Started Seconds and ends with a firmware version screenUsing the AutoDome 700 Series Overview of FeaturesSystem Requirements Connecting the AutoDome 700 Series to the PC Installation manualConfiguring the AutoDome 700 Series Camera Using the Configuration ManagerUsing the AutoDome 700 Series Web Server Network Settings5The Livepage Display StampingMaximum Number of Connections Image Selection Protected AutoDome 700 SeriesProtected Network View ControlDigital I/O Triggering RelaySystem Log / Event Log To View a Preset Shot To Enter a Keyboard Control CommandTo Set a Preset Shot Aux Control TabRecording Video Sequences Image ResolutionSaving Snapshots Processor LoadAudio Line Input Specifications VG5 Audio ConnectionsContact Description Activating Audio Reception Enabling Audio Transmission Navigation Configuring the AutoDome 700 SeriesStarting Configuration Making ChangesBasic Mode Device Access Basic Mode Date/TimeBasic Mode Network Page Basic Mode System Overview Basic Mode AudioBasic Mode Recording Advanced Mode GeneralPassword Initiator extensionDevice date/Device time Date/TimeDate format Device time zoneDisplay Stamping Advanced Mode Web Interface Appearance Livepage Functions Advanced Mode Camera Installer Menu LoggingEncoder Profile Bosch Security Systems, Inc 01U.215.777 1.0 Profile name Video resolutionExpert Settings Target data rateEncoder Streams Privacy Masks PreviewJpeg stream Camera Settings Night Mode Threshold High Sensitivity Setting StabilizationNight Mode ShutterLens Settings PTZ Settings DiagnosticsPreposition and Tours To define and edit an individual sceneTo define a preposition tour Logs SectorsMiscellaneous AudioAdvanced Mode Recording Storage Management Formatting Storage Media Deactivating Storage MediaRecording Profiles Recording Schedule Virtual alarmRetention Time Recording includesRecording Status Destination password Advanced Mode Alarm Alarm ConnectionsConnect on alarm Number of destination IP addressVideo output Video transmissionRemote port Decoder39 VCA VCA configurationAlarm status VCA ProfilesMinimum object size MOTION+ only Motion detector MOTION+ onlySensitivity MOTION+ only Select Area MOTION+ onlySensitivity Trigger delay sTamper detection Global changeAudio Alarm Alarm E-Mail Alarm Task Editor Alarm RulesAdvanced Mode Interfaces Alarm Inputs Advanced Mode Network Network AccessRelay Http browser port Automatic IP assignmentDNS server address Https browser portRCP+ port Interface mode ETHEnable DynDNS Telnet supportAdvanced UPnP EnableMulticast TCP Metadata PortFTP Posting Advanced Mode Service Maintenance EncryptionFirmware Upload LicensesSystem Overview DownloadIf O.K., then If there is power to the AutoDome, then Troubleshooting GuideIf O.K., then If using a non-Bosch power supply VG5 AutoDome Operation and Control3VG5 Series AutoDome Audio Problem Solution No NetworkVG5 700 Series AutoDome Video and Control ConnectionProblem Solution No Audio Problem Solution If O.K., then Poor AudioUser Command Table Symbols IndexJpeg Vidos Page Page Page Page Page Page Bosch Security Systems, Inc