42 en Configuring the AutoDome 700 Series | AutoDome 700 Series IP PTZ Camera |
|
|
Virtual alarm
Here you can select the virtual alarm sensors that are to trigger a recording, via RCP+ commands or alarm scripts, for example.
NOTICE!
For more information, please see the Alarm Task Script Language document and the RCP+ documentation. These documents can be found on the product CD supplied.
Recording includes
You can specify whether, in addition to video data and metadata (for example alarms, VCA data and serial data) should also be recorded. Including metadata could make subsequent searches of recordings easier but it requires additional memory capacity.
CAUTION!
Without metadata, it is not possible to include video content analysis in recordings.
4.34Retention Time
You can specify the retention times for recordings. If the available memory capacity of a medium has been used, older recordings are only overwritten if the retention time entered here has expired.
NOTICE!
Make sure that the retention time corresponds with the available memory capacity. A rule of thumb for the memory requirement is as follows: 1 GB per hour retention time with 4CIF for complete frame rate and high image quality.
Retention time
Enter the required retention time in hours or days for each recording. Recording 1 corresponds to Stream 1, Recording 2 corresponds to Stream 2.
4.35Recording Schedule
The recording scheduler allows you to link the created recording profiles with the days and times at which the camera's images are to be recorded in the event of an alarm.
You can link any number of
In addition to the normal weekdays, you can define holidays that are not in the standard weekly schedule on which recordings are to apply. This allows you to apply a schedule for Sundays to other days with dates that fall on varying weekdays.
1.Click the profile you want to link in the Time periods field.
2.Click in a field in the table, hold down the mouse button and drag the cursor over all the periods to be assigned to the selected profile.
3.Use the right mouse button to deselect any of the intervals.
4.Click the Select All button to link all time intervals to the selected profile.
5.Click the Clear All button to deselect all of the intervals.
6.When you are finished, click the Set button to save the settings in the unit.
F.01U.215.777 1.0 2011.07 | User Manual | Bosch Security Systems, Inc. |