FlexiDome2X

Installation en 19

 

 

3.3.3Surface mounting

When using the surface mounting box:

With a side connection, remove the cap covering the side entrance.

With a rear connection, leave the cap in place.

Attach the conduit to the mounting box.

Release the two clips at the bottom of the watertight connection compartment to remove it from the mounting box.

Open the cover of the watertight compartment in the mounting box by releasing the five clips.

Run the power and video cables through separate rubber grommets into the watertight compartment.

Run the cable from the camera into the watertight compartment through the supplied grommet.

Make the connection inside the watertight compartment and clip on the cover to seal it.

Figure 3.5 Surface mounting box VDA-455SMB

Note:

To ensure a watertight cable entry, use round cables of between 5 and 6 mm (0.2 - 0.24 inches) for power and video connection.

Note:

Use some silicon spray on the cable to help slide the grommets onto it.

Bosch Security Systems

Installation Manual

AR18-08-B010 v1.0 2009.03

Image 17
Contents FlexiDome2X Page Table of Contents Maintenance TroubleshootingTechnical Data GlossarySafety precautions SafetyImportant safety instructions Connection in outdoor applications Safety precautionsEn Safety FlexiDome2X FCC & Ices Information FCC informationInformations FCC et Ices Bosch notice UL certificationDisclaimer More informationIntroduction FeaturesUnpacking InstallationSurface-mount version consists of the following parts DisassemblyFlush-mount version consists of the following parts Mounting tips Mounting the unitFlush mounting Surface mounting box VDA-455SMB Surface mountingEn Installation FlexiDome2X Connection and set-up Power and video connectionsEn Connection and set-up FlexiDome2X Camera positioning Setting up the cameraAR18-08-B010 v1.0 Installation Manual Navigation Menu navigationHeater Focal length and focusClosing the unit Menu access ConfigurationInstall menu Main menuAR18-08-B010 v1.0 Installation Manual Camera control communication Bilinx Day/Night switchingDisabled camera buttons Selection Description Mode submenuMain menu structure ALC level ALC submenuPeak/average ALC speedShutter/AGC submenu 4 Day/Night submenu Switch levelSensUp DynamicPriority Auto modeIR contrast Color burstDynamic Off, XF-DYN Enhance / Dynamic Engine submenuSmartBLC Black levelColor submenu VMD submenu Selecting an area for VMD masking Install menu structure Connections submenu Language submenuTest pattern Test signal submenuShow camera Camera ID submenu Selecting an area for privacy masking Defaults submenuPrivacy masking submenu Resolving problems TroubleshootingCustomer service Malfunction Possible causes SolutionTransfer and disposal MaintenanceRepairs Specifications Technical DataWeight PowerTemperature ALC lensDimensions Dimensions Surface-mount Accessories AES 58 en FlexiDome2X FlexiDome2X 60 en FlexiDome2X OSD 62 en FlexiDome2X Number of pixel changes exceeds a user-configured threshold Between the two images. An alarm is generated whenVideo Motion Detection An algorithm for motion detection Image and counts the number of pixels that have changedPage Bosch Security Systems