Bosch Appliances VDN-0498 installation manual en FlexiDome2X

Page 55

62 en

FlexiDome2X

 

 

S

Saturation

The amplitude of the chrominance signal affecting the vividness of the color.

Sensitivity

A measure of the amount of light required to provide a standard video signal. Sensitivity values are stated in lux (see Lux).

SensUp (sensitivity up)

Increases camera sensitivity by increasing the integration time on the CCD (lowering shutter time from 1/50 s to 1/5 s in PAL or 1/60 s to 1/6 s in NTSC). This is accomplished by integrating the signal from a number of consecutive video fields to reduce signal noise.

Signal-to-noise ratio

The ratio between a useful video signal and unwanted noise measured in dB.

Smart BLC (Back Light Compensation)

Smart back-light compensation allows the camera to automatically compensate for bright areas of a high contrast scene without having to define a window or area.

U

UTP (Unshielded Twisted Pair)

A variant of twisted pair cabling, UTP cable is not surrounded by any shielding. The wires in a twisted pair cable are twisted around each other to minimize interference from the other twisted pairs in the cable. UTP is the primary wire type for telephone usage and the most commonly used type of networking cable.

AR18-08-B010 v1.0 2009.03

Installation Manual

Bosch Security Systems

Image 55
Contents FlexiDome2X Page Table of Contents Glossary TroubleshootingMaintenance Technical DataSafety precautions SafetyImportant safety instructions Connection in outdoor applications Safety precautionsEn Safety FlexiDome2X FCC & Ices Information FCC informationInformations FCC et Ices More information UL certificationBosch notice DisclaimerIntroduction FeaturesUnpacking InstallationFlush-mount version consists of the following parts DisassemblySurface-mount version consists of the following parts Mounting tips Mounting the unitFlush mounting Surface mounting box VDA-455SMB Surface mountingEn Installation FlexiDome2X Connection and set-up Power and video connectionsEn Connection and set-up FlexiDome2X Camera positioning Setting up the cameraAR18-08-B010 v1.0 Installation Manual Navigation Menu navigationHeater Focal length and focusClosing the unit Main menu ConfigurationMenu access Install menuAR18-08-B010 v1.0 Installation Manual Disabled camera buttons Day/Night switchingCamera control communication Bilinx Main menu structure Mode submenuSelection Description ALC speed ALC submenuALC level Peak/averageShutter/AGC submenu Dynamic Switch level4 Day/Night submenu SensUpColor burst Auto modePriority IR contrastBlack level Enhance / Dynamic Engine submenuDynamic Off, XF-DYN SmartBLCColor submenu VMD submenu Selecting an area for VMD masking Install menu structure Connections submenu Language submenuShow camera Test signal submenuTest pattern Camera ID submenu Privacy masking submenu Defaults submenuSelecting an area for privacy masking Malfunction Possible causes Solution TroubleshootingResolving problems Customer serviceRepairs MaintenanceTransfer and disposal Specifications Technical DataALC lens PowerWeight TemperatureDimensions Dimensions Surface-mount Accessories AES 58 en FlexiDome2X FlexiDome2X 60 en FlexiDome2X OSD 62 en FlexiDome2X Image and counts the number of pixels that have changed Between the two images. An alarm is generated whenNumber of pixel changes exceeds a user-configured threshold Video Motion Detection An algorithm for motion detectionPage Bosch Security Systems