Bosch Appliances VDN-0498 installation manual Mounting the unit, Mounting tips

Page 15

FlexiDome2X

Installation en 17

 

 

To disassemble the unit proceed as follows:

1.Use the special screwdriver bit to loosen the three tamper- resistant screws in the trim ring (the screws remain in place).

2.Remove the trim ring and dome by pulling them from the base.

3.Remove the inner liner (with sealing ring) by pulling it off of the base.

4.Remove the pink protective foam.

3.3Mounting the unit

There are several ways to mount the unit. The method of mounting depends on the type of surface and whether other mounting hardware, such as an electrical box, a surface box or other accessories are used.

Note:

If the unit is to be surface mounted, then use the Surface Mount Box (SMB). The SMB is sold as a separate item (VDA-455SMB) or is included with the FlexiDome2X with the surface mount option. Other mounting accessories are also sold separately.

3.3.1Mounting tips

Use the mounting hole template to assist in marking the correct position for the camera to be mounted.

Refer to the dimensions on the mounting hole template to find the exact position of the screw holes and the entry hole for the cables.

Partially screw in two screws for the keyholes and use them to temporarily hang the camera while the connections are made.

Bosch Security Systems

Installation Manual

AR18-08-B010 v1.0 2009.03

Image 15
Contents FlexiDome2X Page Table of Contents Glossary TroubleshootingMaintenance Technical DataSafety precautions SafetyImportant safety instructions Connection in outdoor applications Safety precautionsEn Safety FlexiDome2X FCC & Ices Information FCC informationInformations FCC et Ices More information UL certificationBosch notice Disclaimer Introduction FeaturesUnpacking InstallationDisassembly Flush-mount version consists of the following partsSurface-mount version consists of the following parts Mounting tips Mounting the unitFlush mounting Surface mounting box VDA-455SMB Surface mountingEn Installation FlexiDome2X Connection and set-up Power and video connectionsEn Connection and set-up FlexiDome2X Camera positioning Setting up the cameraAR18-08-B010 v1.0 Installation Manual Navigation Menu navigationHeater Focal length and focusClosing the unit Main menu ConfigurationMenu access Install menuAR18-08-B010 v1.0 Installation Manual Day/Night switching Disabled camera buttonsCamera control communication Bilinx Mode submenu Main menu structureSelection Description ALC speed ALC submenuALC level Peak/averageShutter/AGC submenu Dynamic Switch level4 Day/Night submenu SensUpColor burst Auto modePriority IR contrastBlack level Enhance / Dynamic Engine submenuDynamic Off, XF-DYN SmartBLCColor submenu VMD submenu Selecting an area for VMD masking Install menu structure Connections submenu Language submenuTest signal submenu Show cameraTest pattern Camera ID submenu Defaults submenu Privacy masking submenuSelecting an area for privacy masking Malfunction Possible causes Solution TroubleshootingResolving problems Customer serviceMaintenance RepairsTransfer and disposal Specifications Technical DataALC lens PowerWeight TemperatureDimensions Dimensions Surface-mount Accessories AES 58 en FlexiDome2X FlexiDome2X 60 en FlexiDome2X OSD 62 en FlexiDome2X Image and counts the number of pixels that have changed Between the two images. An alarm is generated whenNumber of pixel changes exceeds a user-configured threshold Video Motion Detection An algorithm for motion detectionPage Bosch Security Systems