Bosch Appliances VDN-0498 installation manual 4 Day/Night submenu, SensUp, Dynamic, Switch level

Page 32

FlexiDome2XConfiguration en 35

Item

Selection

Description

 

 

 

SensUp

Off, 2x, 3x, …,

Selects the factor by which the sensitivity of

Dynamic

10x

the camera is increased. It is dynamic and so

 

 

is only active when light levels are low.

 

 

When active, some noise or spots may appear

 

 

in the picture. This is normal camera

 

 

behavior. It may also cause motion blur on

 

 

moving objects.

 

 

 

EXIT

 

Returns to main menu.

 

 

 

5.5.4Day/Night submenu

Item

Selection

Description

 

 

 

Day/Night

Auto, Color,

Auto - the camera switches the IR cut-off filter

 

Monochrome

on and off depending on the scene

 

 

illumination level.

 

 

Monochrome - the IR cut-off filter is removed,

 

 

giving full IR sensitivity.

 

 

Color - the camera always produces a color

 

 

signal regardless of light levels.

 

 

 

Switch level

-15 to +15

Sets the video level in Auto mode at which

 

 

the camera switches to monochrome

 

 

operation.

 

 

A low (negative) value means that the camera

 

 

switches to monochrome at a lower light

 

 

level. A high (positive) value means that the

 

 

camera switches to monochrome at a higher

 

 

light level.

 

 

 

Bosch Security Systems

Installation Manual

AR18-08-B010 v1.0 2009.03

Image 32
Contents FlexiDome2X Page Table of Contents Troubleshooting MaintenanceTechnical Data GlossarySafety Safety precautionsImportant safety instructions Safety precautions Connection in outdoor applicationsEn Safety FlexiDome2X FCC information FCC & Ices InformationInformations FCC et Ices UL certification Bosch noticeDisclaimer More informationFeatures IntroductionInstallation UnpackingSurface-mount version consists of the following parts DisassemblyFlush-mount version consists of the following parts Mounting the unit Mounting tipsFlush mounting Surface mounting Surface mounting box VDA-455SMBEn Installation FlexiDome2X Power and video connections Connection and set-upEn Connection and set-up FlexiDome2X Setting up the camera Camera positioningAR18-08-B010 v1.0 Installation Manual Menu navigation NavigationFocal length and focus HeaterClosing the unit Configuration Menu accessInstall menu Main menuAR18-08-B010 v1.0 Installation Manual Camera control communication Bilinx Day/Night switchingDisabled camera buttons Selection Description Mode submenuMain menu structure ALC submenu ALC levelPeak/average ALC speedShutter/AGC submenu Switch level 4 Day/Night submenuSensUp DynamicAuto mode PriorityIR contrast Color burstEnhance / Dynamic Engine submenu Dynamic Off, XF-DYNSmartBLC Black levelColor submenu VMD submenu Selecting an area for VMD masking Install menu structure Language submenu Connections submenuTest pattern Test signal submenuShow camera Camera ID submenu Selecting an area for privacy masking Defaults submenuPrivacy masking submenu Troubleshooting Resolving problemsCustomer service Malfunction Possible causes SolutionTransfer and disposal MaintenanceRepairs Technical Data SpecificationsPower WeightTemperature ALC lensDimensions Dimensions Surface-mount Accessories AES 58 en FlexiDome2X FlexiDome2X 60 en FlexiDome2X OSD 62 en FlexiDome2X Between the two images. An alarm is generated when Number of pixel changes exceeds a user-configured thresholdVideo Motion Detection An algorithm for motion detection Image and counts the number of pixels that have changedPage Bosch Security Systems