26 en Connection and set-up

FlexiDome2X

 

 

4.2.3Focal length and focus

Before adjusting the focal length or focus, place the lens adjustment cap on the lens to ensure that the image sharpness is the same as when the dome is in place.

1.Connect a monitor or other display device to either the camera’s BNC connector or to the optional cable (S1460) on the monitor jack. (If S1460 is connected, there is no signal on the BNC connector.)

2.Press and hold the menu/select (center) button until the Install menu appears.

The Set focus item is highlighted. Do not change this selection as the camera is now in a special mode for adjusting focus.

3.To set the field of view of the varifocal lens, loosen the focal length screw and turn the mechanism until the required view is displayed on the monitor. (Image goes out of focus.)

4.Focus the image on the monitor by loosening the focus screw and turning the mechanism until the image is in focus.

5.Re-adjust the focal length if necessary.

6.Repeat these two adjustments until the desired view is in focus.

7.Tighten both screws.

8.Use the navigation buttons to move to Exit and press the center button until the menu disappears.

9.Remove the lens adjustment cap from the lens and disconnect the monitor.

4.2.4Heater

When using the camera at low temperatures, set the heater setting to Auto in the Install menu. The heater turns on at ambient temperatures below 0°C (+32°F).

AR18-08-B010 v1.0 2009.03

Installation Manual

Bosch Security Systems

Image 24
Contents FlexiDome2X Page Table of Contents Troubleshooting MaintenanceTechnical Data GlossarySafety Safety precautionsImportant safety instructions Safety precautions Connection in outdoor applicationsEn Safety FlexiDome2X FCC information FCC & Ices InformationInformations FCC et Ices UL certification Bosch noticeDisclaimer More informationFeatures IntroductionInstallation UnpackingDisassembly Flush-mount version consists of the following partsSurface-mount version consists of the following parts Mounting the unit Mounting tipsFlush mounting Surface mounting Surface mounting box VDA-455SMBEn Installation FlexiDome2X Power and video connections Connection and set-upEn Connection and set-up FlexiDome2X Setting up the camera Camera positioningAR18-08-B010 v1.0 Installation Manual Menu navigation NavigationFocal length and focus HeaterClosing the unit Configuration Menu accessInstall menu Main menuAR18-08-B010 v1.0 Installation Manual Day/Night switching Disabled camera buttonsCamera control communication Bilinx Mode submenu Main menu structureSelection Description ALC submenu ALC levelPeak/average ALC speedShutter/AGC submenu Switch level 4 Day/Night submenuSensUp DynamicAuto mode PriorityIR contrast Color burstEnhance / Dynamic Engine submenu Dynamic Off, XF-DYNSmartBLC Black levelColor submenu VMD submenu Selecting an area for VMD masking Install menu structure Language submenu Connections submenuTest signal submenu Show cameraTest pattern Camera ID submenu Defaults submenu Privacy masking submenuSelecting an area for privacy masking Troubleshooting Resolving problemsCustomer service Malfunction Possible causes SolutionMaintenance RepairsTransfer and disposal Technical Data SpecificationsPower WeightTemperature ALC lensDimensions Dimensions Surface-mount Accessories AES 58 en FlexiDome2X FlexiDome2X 60 en FlexiDome2X OSD 62 en FlexiDome2X Between the two images. An alarm is generated when Number of pixel changes exceeds a user-configured thresholdVideo Motion Detection An algorithm for motion detection Image and counts the number of pixels that have changedPage Bosch Security Systems