Bosch Appliances VDN-0498 installation manual Connection and set-up, Power and video connections

Page 19

FlexiDome2X

Connection and set-up en 21

 

 

4Connection and set-up

4.1Power and video connections

The wiring harness has a BNC connector to accept the video coax cable (with male BNC connector) and two stripped low voltage power wires for connection to a power connector. A UTP adapter (VDA-455UTP) is available as an optional accessory to allow a UTP video cable to be connected to the BNC connector.

WARNING!

!Before proceeding, disconnect the power from the power supply cable. Ensure that the voltage of the unit matches the

voltage and type of the power supply being used.

The easiest way to connect the cables is as follows:

1.Bring the building connections through the surface cable hole so that they hang clear.

2.Partially insert two screws into the pre-drilled holes (or adapter plate).

3.Using one of the keyholes, hang the mounting base of the camera module on one screw temporarily; tilt the base slightly to gain access to the cable connections.

4.Connect the BNC connector of the camera module to the video coax cable.

5.Connect the stripped power wires (red +, brown –) to the power supply connector.

Note

For a DC supply the polarity is important. Incorrect polarity does not damage the camera but it will not switch on.

For an AC supply maintain a consistent wiring polarity in multiple camera systems to help avoid potential camera video rolling.

Bosch Security Systems

Installation Manual

AR18-08-B010 v1.0 2009.03

Image 19
Contents FlexiDome2X Page Table of Contents Glossary TroubleshootingMaintenance Technical DataSafety precautions SafetyImportant safety instructions Connection in outdoor applications Safety precautionsEn Safety FlexiDome2X FCC & Ices Information FCC informationInformations FCC et Ices More information UL certificationBosch notice DisclaimerIntroduction FeaturesUnpacking InstallationFlush-mount version consists of the following parts DisassemblySurface-mount version consists of the following parts Mounting tips Mounting the unit Flush mounting Surface mounting box VDA-455SMB Surface mountingEn Installation FlexiDome2X Connection and set-up Power and video connectionsEn Connection and set-up FlexiDome2X Camera positioning Setting up the cameraAR18-08-B010 v1.0 Installation Manual Navigation Menu navigationHeater Focal length and focusClosing the unit Main menu ConfigurationMenu access Install menuAR18-08-B010 v1.0 Installation Manual Disabled camera buttons Day/Night switchingCamera control communication Bilinx Main menu structure Mode submenuSelection Description ALC speed ALC submenuALC level Peak/averageShutter/AGC submenu Dynamic Switch level4 Day/Night submenu SensUpColor burst Auto modePriority IR contrastBlack level Enhance / Dynamic Engine submenuDynamic Off, XF-DYN SmartBLCColor submenu VMD submenu Selecting an area for VMD masking Install menu structure Connections submenu Language submenuShow camera Test signal submenuTest pattern Camera ID submenu Privacy masking submenu Defaults submenuSelecting an area for privacy masking Malfunction Possible causes Solution TroubleshootingResolving problems Customer serviceRepairs MaintenanceTransfer and disposal Specifications Technical DataALC lens PowerWeight TemperatureDimensions Dimensions Surface-mount Accessories AES 58 en FlexiDome2X FlexiDome2X 60 en FlexiDome2X OSD 62 en FlexiDome2X Image and counts the number of pixels that have changed Between the two images. An alarm is generated whenNumber of pixel changes exceeds a user-configured threshold Video Motion Detection An algorithm for motion detectionPage Bosch Security Systems