5.3Day/Night switching

The camera is equipped with a motorized IR filter. The mechanical IR filter can be removed in low-light or IR illuminated applications by software configuration settings. If Auto switching mode is selected, the camera automatically switches the filter depending on the observed light level. The switching level is programmable. In Auto switching mode the camera prioritizes motion (the camera gives sharp images without motion blur as long as the light level permits) or color (the camera gives color pictures as long as the light level permits). The camera recognizes IR illuminated scenes to prevent unwanted switching to color mode.

There are four different methods of controlling the IR filter:

via an alarm input,

via Bilinx communication,

automatically, based on the observed light levels, or

as part of the programmable mode profile.

5.4Camera control communication (Bilinx)

This camera is equipped with a coaxial communications transceiver (also refered to as Bilinx). In combination with VP- CFGSFT, the camera setting can be changed from any point along the coaxial cable. All menus can be accessed remotely giving full control of the camera. With this method of communication it is also possible to disable the local keys on the camera.

To avoid loss of communication on an installed camera, the Communication On/Off selection is not available while using remote control. This function can only be accessed with the camera buttons. Bilinx communications can only be disabled using the buttons on the camera.

Disabled camera buttons

When the Bilinx communications link is active, the buttons on the camera are disabled.

Bosch Security Systems

Installation Manual

AR18-08-B010 v1.0 2009.03

Image 28
Contents FlexiDome2X Page Table of Contents Troubleshooting MaintenanceTechnical Data GlossarySafety Safety precautionsImportant safety instructions Safety precautions Connection in outdoor applicationsEn Safety FlexiDome2X FCC information FCC & Ices InformationInformations FCC et Ices UL certification Bosch noticeDisclaimer More informationFeatures IntroductionInstallation UnpackingFlush-mount version consists of the following parts DisassemblySurface-mount version consists of the following parts Mounting the unit Mounting tipsFlush mounting Surface mounting Surface mounting box VDA-455SMBEn Installation FlexiDome2X Power and video connections Connection and set-upEn Connection and set-up FlexiDome2X Setting up the camera Camera positioningAR18-08-B010 v1.0 Installation Manual Menu navigation NavigationFocal length and focus HeaterClosing the unit Configuration Menu accessInstall menu Main menuAR18-08-B010 v1.0 Installation Manual Disabled camera buttons Day/Night switchingCamera control communication Bilinx Main menu structure Mode submenuSelection Description ALC submenu ALC levelPeak/average ALC speedShutter/AGC submenu Switch level 4 Day/Night submenuSensUp DynamicAuto mode PriorityIR contrast Color burstEnhance / Dynamic Engine submenu Dynamic Off, XF-DYNSmartBLC Black levelColor submenu VMD submenu Selecting an area for VMD masking Install menu structure Language submenu Connections submenuShow camera Test signal submenuTest pattern Camera ID submenu Privacy masking submenu Defaults submenuSelecting an area for privacy masking Troubleshooting Resolving problemsCustomer service Malfunction Possible causes SolutionRepairs MaintenanceTransfer and disposal Technical Data SpecificationsPower WeightTemperature ALC lensDimensions Dimensions Surface-mount Accessories AES 58 en FlexiDome2X FlexiDome2X 60 en FlexiDome2X OSD 62 en FlexiDome2X Between the two images. An alarm is generated when Number of pixel changes exceeds a user-configured thresholdVideo Motion Detection An algorithm for motion detection Image and counts the number of pixels that have changedPage Bosch Security Systems