Selecting an area for VMD masking

To set-up an area for VMD masking, access the area menu by selecting the VMD Area option from the VMD menu. Upon entering the Area menu, the current area is displayed with the upper left corner flashing. The flashing corner of the image can be moved with the Up, Down, Left, Right arrow keys. Pressing the Select key moves the flashing cursor to the opposite corner, which can now be moved. Pressing Select again freezes the area and exits the area menu.

There is one programmable VMD area.

Note:

When VMD is enabled, normal light fluctuations or environmental factors can contribute to false-positive alarms. Because of this, it is recommended that you do not connect the VMD-triggered alarm output of the camera to a monitored alarm system as the false-positive alarms may be considered a nuisance.

AR18-08-B010 v1.0 2009.03

Installation Manual

Bosch Security Systems

Image 37
Contents FlexiDome2X Page Table of Contents Maintenance TroubleshootingTechnical Data GlossarySafety precautions SafetyImportant safety instructions Connection in outdoor applications Safety precautionsEn Safety FlexiDome2X FCC & Ices Information FCC informationInformations FCC et Ices Bosch notice UL certificationDisclaimer More informationIntroduction FeaturesUnpacking InstallationFlush-mount version consists of the following parts DisassemblySurface-mount version consists of the following parts Mounting tips Mounting the unitFlush mounting Surface mounting box VDA-455SMB Surface mountingEn Installation FlexiDome2X Connection and set-up Power and video connectionsEn Connection and set-up FlexiDome2X Camera positioning Setting up the cameraAR18-08-B010 v1.0 Installation Manual Navigation Menu navigationHeater Focal length and focusClosing the unit Menu access ConfigurationInstall menu Main menuAR18-08-B010 v1.0 Installation Manual Disabled camera buttons Day/Night switchingCamera control communication Bilinx Main menu structure Mode submenuSelection Description ALC level ALC submenuPeak/average ALC speedShutter/AGC submenu 4 Day/Night submenu Switch levelSensUp DynamicPriority Auto modeIR contrast Color burst Dynamic Off, XF-DYN Enhance / Dynamic Engine submenu SmartBLC Black levelColor submenu VMD submenu Selecting an area for VMD masking Install menu structure Connections submenu Language submenuShow camera Test signal submenuTest pattern Camera ID submenu Privacy masking submenu Defaults submenuSelecting an area for privacy masking Resolving problems TroubleshootingCustomer service Malfunction Possible causes SolutionRepairs MaintenanceTransfer and disposal Specifications Technical DataWeight PowerTemperature ALC lensDimensions Dimensions Surface-mount Accessories AES 58 en FlexiDome2X FlexiDome2X 60 en FlexiDome2X OSD 62 en FlexiDome2X Number of pixel changes exceeds a user-configured threshold Between the two images. An alarm is generated whenVideo Motion Detection An algorithm for motion detection Image and counts the number of pixels that have changedPage Bosch Security Systems