Axis strongly recommends that you do not use this function unless you understand the consequences. Axis Support does not provide assistance for problems with customized scripts.

To open the Script Editor, go to System Options > Advanced > Scripting. If a script causes problems, reset the product to its factory default settings, see page 59.

For more information, see www.axis.com/developer

File Upload

Files, for example web pages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.

Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.

Plain Config

Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page.

To open Plain Config, go to System Options > Advanced > Plain Config . Axis Support does not provide assistance.

Reset to Factory Default Settings

Important

Reset to factory default should be used with caution. A reset to factory default will reset all settings, including the IP address, to the factory default values.

Note

The installation and management software tools are available on the CD supplied with the product and from the support pages on www.axis.com/techsup

To reset the product to the factory default settings:

1.Disconnect power from the product.

2.Press and hold the control button and reconnect power. See Hardware Overview on page 6 .

3.Keep the control button pressed for about 15–30 seconds until the status LED indicator flashes amber.

4.Release the control button. The process is complete when the status LED indicator turns green. The product has been reset to the factory default settings. If no DHCP server is available on the network, the default IP address is 192.168.0.90

5.Using the installation and management software tools, assign an IP address, set the password, and access the video stream.

6.Refocus the product.

It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.

59

Image 59
Contents Axis Q1614 Network Camera Intellectual Property Rights About this DocumentLegal Considerations LiabilityLearn More SupportAxis Q1614 Network Camera Table of ContentsConnectors Technical SpecificationsStorage Ports Maintenance Support Advanced Hardware Overview Connectors and ButtonsFor technical specifications, see Audio Connector Network ConnectorConnector Power ConnectorColor Indication LED IndicatorsStatus LED Behavior for Focus Assistant Function ButtonLens Buzzer Signal for Focus AssistantReplace the Lens BuzzerAxis Q1614 Network Camera Set the Root Password Access the ProductAccess from a Browser Access from the InternetLive View PTZ ModeConfigure Capture Mode Set Power Line FrequencyTo show the manual trigger buttons in the Live View Go to Setup EventsControls on the Live View Manual TriggerAMC Audio Controls Axis Media Control viewer toolbarPTZ Controls Axis Q1614 Network Camera Axis Media Control AMC How to Stream H.264Media Streams QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamJava applet supports simplex audio with G.711 encoding Access Audio StreamsFocus Adjustment Set Up the ProductBasic Setup Image Video and AudioVideo Stream Pixel Counter264 Click Save to apply the new settingsStream Profiles Go to Setup Video & Audio Camera Settings Camera SettingsCapture Mode White Balance Lightfinder ModeExposure Settings Image AppearanceDay/Night Iris configurationIris adjustment Set Shutter toGo to Video & Audio Video Stream and select the Image tab To configure the view areaView Area OverlayGo to Video & Audio Overlay Image Overlay ImageUse Overlay Text in an Action Rule Basic Privacy MaskFocus Go to Events Action RulesAudio Input Audio SettingsAudio Modes Audio Output Audio ClipsBrowser Viewer Description Configure the Live ViewDefault Viewer for Browsers Viewer SettingsFor more information about I/O ports, see I/O Ports on Go to Setup Live View ConfigUser Defined Links Output ButtonsGuard Tour Preset PositionsGo to PTZ Preset Positions PTZ Pan Tilt ZoomControl Queue Install PTZ DriverDevice Settings AdvancedOperator Same as administrator but with lower priority Shock Detection DetectorsCamera Tampering Motion DetectionParameter Object Size History Sensitivity Description Set Up Motion Detection WindowsMotion Detection Parameters Go to Detectors Motion DetectionAudio Detection Application Licenses Install ApplicationGo to Setup Applications ApplicationsAxis Q1614 Network Camera Go to Events Action Rules and click Add Set Up Action RulesEvents TriggersSystem Input SignalHardware StoragePTZ Control Set Up Email RecipientsAdd Recipients ActionsGo to Events Schedules and click Add Set Up RecurrencesCreate Schedules To create a new scheduleGo to Recordings List RecordingsFind Recordings Play RecordingGo to Recordings Continuous Export Video ClipContinuous Recording To play a recording, follow these stepsLanguages IP Address Filter System OptionsSecurity UsersGo to System Options Security Ieee IeeeCertificates Date & Time To install a self-signed certificateGo to Setup System Options Security Certificates Click Install certificate and upload the certificateNetwork Basic TCP/IP SettingsDNS Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service Axis Internet Dynamic DNS Service requires IPv4NAT traversal port mapping for IPv4 NTP ConfigurationHost Name Configuration Link-Local IPv4 AddressFTP QoS Quality of ServiceRTP/H.264 UPnPTM can be disabled under System Options Network UPnPTMUPnPTM Mount and Unmount SD Card StorageBonjour SD CardGo to System Options Storage Click Network Share Under General Settings, select Autoformat toNetwork Share To add a network sharePorts MaintenanceLogs & Reports SupportSupport Overview System OverviewFile Upload Reset to Factory Default SettingsPlain Config Check the Firmware TroubleshootingUpgrade the Firmware Emergency Recovery ProcedureProduct is accessible locally but not externally Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserSetup Video & Audio Camera Settings Problems with streaming H.264Status and Network indicator LEDs are flashing red rapidly Video and image problems, generalPoor audio quality SettingsStorage and disk management problems No audioTechnical Specifications Audio output Function/group Specifications AudioSpecification Network Security Audio inputWeight Function/group Specifications Video bufferPower ConnectorsFunction Pin Specifications ConnectorsFunction/group Specifications Warranty ConnectorFunction Pin RS485/422 ConnectorPerformance Considerations OutputAxis Q1614 Network Camera M4.4