Axis Communications axis communications dome network camera Audio Settings, Audio Modes, G711

Page 21

AXIS Q6035 PTZ Dome Network Camera

Video and Audio

Audio Settings

The audio functionality for each video stream is enabled under Video & Audio > Video Stream > Audio.

Note

Amulti-connector cable (available from Axis; Multi-Connector Cable (sold separately)) is required when connecting external audio equipment to the Axis product.

Audio Modes

The Axis product supports the following audio modes:

Full duplex - Simultaneous two-way audio allowing the Axis product to transmit and receive audio at the same time. There is no echo cancellation; if feedback loops appear, try moving the microphone or the speaker.

Half-duplex - Audio can be transmitted to and from the Axis product but only in one direction at a time. To transmit audio using the Live View page, use the Talk and Listen buttons, see AMC Audio Controls, on page 10.

Simplex — speaker only - Audio is transmitted from a client to the Axis product and can be played by a speaker connected to the product. To transmit audio using the Live View page, the Talk and Microphone buttons must both be active, see AMC Audio Controls, on page 10.

Simplex — microphone only - Audio captured by the product microphone is transmitted from the Axis product to one or more clients.

To set the audio mode, go to Video & Audio > Audio Settings and select the desired mode from the Audio mode drop-down list.

Audio Input

An external microphone or a line source can be connected to the product’s Audio-in connector. Configure the audio input settings under Video & Audio > Audio Settings.

Note

Amulti-connector cable (available from Axis; Multi-Connector Cable (sold separately)) is required when connecting external audio equipment to the Axis product.

Source - Select Microphone for an external microphone or Line for a Line in device, e.g. an audio mixer for multiple microphones or a microphone with a built-in amplifier.

Microphone power - The Enable microphone power option provides DC power for an external microphone. Microphone power should only be used with microphones that have no battery. This setting should not be enabled when using a dynamic or battery powered microphone. Microphone power will not harm the microphone; if you are uncertain, try switching it off and on. To use a professional microphone requiring 48V phantom power, you need an external power supply and a balanced-unbalanced converter (audio transformer) in between.

Input gain - Control the volume (dB Full Scale) of the audio input. If the sound is too low, choose a higher dB, to amplify the sound. If the sound is too high, choose a lower dB. The Level bar gives a visual representation of the audio signal level in dB relative to the full-scale input level.

Green — the signal is at a good level.

Yellow — the signal is becoming distorted.

Red — the signal is distorted.

Encoding - Select digital audio encoding format.

AAC requires a license for both encoding and decoding. AAC is the least complicated and most widely used codec. If achieving the best possible audio quality is a priority, AAC is the recommended codec to use. An AAC license is included in the Axis product.

G711

21

Image 21
Contents Axis Q6035 PTZ Dome Network Camera About this document SafetyLiability Intellectual Property RightsAxis Q6035 PTZ Dome Network Camera Table of ContentsSymptoms, Possible Causes and Remedial Actions Hardware Overview ConnectorsHardware Overview For technical specifications, seeLED Indicators Midspan LED IndicatorsColor Indication Accessing the Product Accessing the ProductAccess from a Browser Start a browser Internet Explorer, Firefox, SafariSet the Root Password Access from the InternetConfigure Capture Mode Network TCP/IP AdvancedLive View Controls on the Live ViewAxis Media Control viewer toolbar AMC Audio Controls PTZ ControlsAxis Q6035 PTZ Dome Network Camera Media Streams How to Stream H.264Media Streams Axis Media Control AMCQuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamJava applet supports simplex audio with G.711 encoding Accessing Audio StreamsSetting Up the Product Setting Up the ProductBasic Setup Video and Audio Video and AudioVideo Stream Pixel CounterStream Profiles Click Save to apply the new settingsImage 264Capture Mode Camera SettingsGo to Setup Video & Audio Camera Settings Image AppearanceImage Settings Exposure SettingsOverlay Wide Dynamic RangePrivacy Mask Overlay ImageGo to Video & Audio Overlay Image Audio Modes Audio SettingsAudio Input G711Audio Clips Audio OutputG726 Default Viewer for Browsers Live View ConfigLive View Config Go to Setup Live View Config Viewer SettingsUser Defined Links Output ButtonsAxis Q6035 PTZ Dome Network Camera PTZ Pan Tilt Zoom Preset PositionsPTZ Pan Tilt Zoom AutotrackingConfiguration Exclude AreasMax Limits Guard Tour GatekeeperAdvanced Osdi ZonesTour Recording LimitsOperator Same as administrator but with lower priority Control QueueControls Detectors Set Up Motion Detection WindowsDetectors Motion DetectionMotion Detection Parameters Audio DetectionApplications ApplicationsEvents EventsConvert Event Types to Action Rules Setting Up an Action RulePTZ Control Go to Events Action Rules and click AddSchedules RecipientsRecipient Use with action Go to Events Recipients and click AddGo to Events Recurrences and click Add RecurrencesRecordings RecordingsRecording List Continuous RecordingAxis Q6035 PTZ Dome Network Camera System Options System OptionsSecurity UsersDate & Time IeeeAudio Support Network Basic TCP/IP SettingsIPv4 Address Configuration IPv6 Address ConfigurationAdvanced TCP/IP Settings NAT traversal port mapping for IPv4 Link-Local IPv4 AddressSmtp email QoS Quality of ServiceUPnPTM StorageRTP/H.264 BonjourNetwork Share Ports & DevicesPorts Go to System Options Storage Click Network ShareSupport MaintenanceScripting Reset to Factory Default SettingsFile Upload Plain Config192.168.0.90 Troubleshooting TroubleshootingEmergency Recovery Procedure Checking the FirmwareSymptoms, Possible Causes and Remedial Actions Problems setting the IP addressProduct cannot be accessed from a browser Problems with the H.264 format Product is accessible locally but not externallySetup Video & Audio Camera Settings Video and image problems, generalNo images displayed on web Overlay image is not displayedSettings Problems uploading filesStorage and disk management problems Browser freezesTechnical Specifications Technical SpecificationsMaintenance Installation aidPower ConnectorsMulti-Connector Cable sold separately To +40 V DC Function Pin SpecificationsMax voltage = +40 V DC With the load, for protection against voltage transientsConnection diagram DC power inputPerformance Considerations Axis Q6035 PTZ Dome Network Camera M1.8