Reset to the Factory Default Settings
Any of the above settings plus the ALC/MANUAL level control and phase adjustments can be reset to the fac- tory default settings by placing the cursor over the desired mode and then pressing the F2 button of WV- CU550C/CJ.
For
For
■RS485 Setup
●Initial Camera Communication Parameters
In an RS485 chain, the matrix switcher, PC, controllers and cameras should be set to the same protocol and parameters for communication. Confirm the system pro- tocol and parameters prior to setting the communica- tion parameters for the camera.
The initial communication parameters for
●Changing the Camera Communication Parameters
You can remotely control this camera by using a speci- fied extension unit such as a computer with a modem.
1.Display SET UP MENU. Move the cursor to RS485 SET UP and press the CAM (SET) key. The RS485 SET UP menu appears on the monitor.
** RS485 SET UP **
UNIT NUMBER | 1 |
|
SUB ADDRESS | ||
BAUD RATE | 19200 | |
DATA BIT | 8 |
|
PARITY CHECK | NONE | |
STOP BIT | 1 |
|
XON/XOFF | NOT USE | |
WAIT TIME | OFF | |
ALARM DATA | AUTO2 | |
DELAY TIME | ||
RET |
|
|
2.Move the cursor to the item and select the parame- ter with the joystick.
Unit Number (UNIT NUMBER)
Displays the unit number set by the DIP switch. If the switch is set to
Factory default setting: 1. See INSTALLATION for DIP switch setting.
Sub Address (SUB ADDRESS)
Do not set.
Baud Rate (BAUD RATE)
Specifies the transmission speed (2 400, 4 800, 9 600, 19 200 bit per second) for the RS485 communication. The factory default setting is 19 200.
Data Bit (DATA BIT)
Specifies the number of data bits (7 or 8 bits) for the RS485 communication. The factory default setting is 8.
Parity Check (PARITY CHECK)
Specifies the parity check mode (NONE, ODD, EVEN). The factory default setting is NONE.
Stop Bit (STOP BIT)
Specifies the number of stop bits (1 or 2 bits). The fac- tory default setting is 1.
X ON/X OFF (X ON/X OFF)
Specifies whether to apply flow control or not (USE or NOT USE). The factory default setting is NOT USE.
Wait Time (WAIT TIME)
Specifies the time to wait until retrying after confirming that no data is received from the controller.
(OFF: no retry, 100, 200, 400, 1 000 ms).
Alarm Data (ALARM DATA)
Specifies the alarm transmission mode depending on the protocol selected by the
POLLING: Transmits the alarm data in response to requests from the controller.
AUTO 1: Transmits the alarm data each time an alarm signal is received by the camera.
AUTO 2 (Default): Transmits alarm data at intervals of 5 seconds.
Delay Time (DELAY TIME)
Specifies the time to transmit the acknowledge request when communicating on a
This menu appears only when a
The settings become effective with the closing of SET UP MENU.
Note: Set the same parameters for the cameras, con- trollers and personal computers in an RS485 chain.