Panasonic WV-CW864A operating instructions New Password, Password Verification

Page 26

Password Lock (PASSWORD LOCK)

Caution: For security, do not operate your VCR for recording while the password menus are displayed on the monitor.

A 3-digit number is used for a password to limit access to all settings.

1.Move the cursor to PASSWORD LOCK, then select ON or OFF with the joystick.

** SET UP MENU **

PRESET 1 MAP

HOME POSITION OFF

SELF RETURN OFF

AUTO MODE OFF AUTO PAN KEY AUTO PAN DIGITAL FLIP ON SPECIAL1

CAMERA RS485 SET UP

PASSWORD LOCK OFF

3-5 To return to the SET UP MENU menu without ver- ifying the password, move the cursor to RET, and press the CAM (SET) key.

New Password

4.To change the password in step 3-3 above, move the cursor from OK to NEW PASSWORD, then press the CAM (SET) key. NEW PASSWORD menu appears.

** NEW PASSWORD? **

0 1 2 3 4 5 6 7 8 9

. . .

. . .

OK RESET

RET

** PASSWORD? ** 0 1 2 3 4 5 6 7 8 9

. . .

OK RESET

NEW PASSWORD

RET

Note: ON or OFF can be selected only after going through the password verification.

OFF: You can change all settings.

ON: You cannot change settings at all nor operate AUTO PAN, SEQ, SORT, and PATROL.

2. Press the CAM (SET) key.

Password Verification

3. The password verification menu appears.

3-1 Select a numeral for the first digit with the joy- stick, and press the CAM (SET) key. Though the entered password is not displayed, the up-arrow moves one character to the right.

3-2 Repeat the above step for the 2nd and 3rd dig- its.

Default: 123

3-3 The cursor moves to OK after all the three digits have been entered. Unless you want to change the password, press the CAM (SET) key.

If the correct password is entered, the screen returns to SET UP MENU. ON and OFF settings are the same as made on the SET UP MENU menu is as set in step 1.

If a wrong password is entered, the screen returns to the verification menu. Repeat steps 3-1 to 3-3 to verify the password.

3-4 To cancel an incomplete password, move the cursor to RESET, and press the CAM (SET) key. The screen returns to the verification menu.

-26-

Note: The NEW PASSWORD menu is accessible only after the verification has been completed.

The up-arrow mark appears indicating the first digit on the first line.

4-1 Enter a new three-digit password in the same way as in steps 3-1 to 3-2.

4-2 The cursor moves to OK after all the three digits have been entered. Press the CAM (SET) key to move the cursor to the first digit on the second line.

4-3 Enter the same password as the one you have entered on the first line.

4-4 The cursor moves to OK. Press the CAM (SET) key. If the new password is successfully entered, the screen returns to SET UP MENU.

4-5 Retry steps 4-1 to 4-4. If the first entry for the password is different from the second one, the screen returns to the NEW PASSWORD? menu.

4-6 To return to the SET UP MENU menu without changing the password, move the cursor to RET, and press the CAM (SET) key.

Image 26
Contents Color Cctv Camera English Version Important Safety Instructions EnglishPage Contents Digital Flip Operation FeaturesPreface Preset Data Uploading or Down Loading PrecautionsCamera Cleaning Consumables Do not install this camera upside downDo not install the camera in places subject to vibrations Self-diagnosis FunctionConstruction Setup Setup MenuAUTO/ON/OFF P WV-CU161C WV-CU550C/CJWV-CU360C/CJ WV-RM70Setup Menu Description Camera Synchronization Sync Shutter Speed ShutterGain Control AGC Important Notices10Special 2 Menu SPECIAL2 Auto Focus AF ModeRS485 Communication 11Self-diagnosis FunctionMenu Display Setting ProceduresSetup Menu Display Submenu DisplayPosition Setting Position SET Preset MenuPreset Menu Display To Set Panning/Tilting PositionsPan Offset To Set the Lens Zoom and Focus PositionsPreset Identification Setting Preset ID To Return to the Preset Setting Menu Light Control Setting ALC/MANUALScene File Setting Scene File Dwell Time Dwell TimeTo Return to the Preset Number Set Menu Deleting Preset PositionsPreset Speed Setting Preset Speed To Return to the Setup MenuAuto Mode Selection Auto Home Position Setting HomeSelf Return Setting Self OFF SEQ Sort Auto PAN PatrolZoom →PUSH SET RET SEQ Sort Patrol Auto Pan Key Setting Auto PAN KEYDigital Flip Setting Digital Flip New Password Password VerificationSpecial 1 Menu Setting Special Privacy Zone Privacy ZoneArea Title Area Title Settings for on NeswProportional Pan/Tilt PROPO. P/T Zoom ratioSetting for on User Area Title EditingPatrol Learn with a Controller Having Patrol Key Patrol-learn and Patrol Play PatrolTo Quit Editing PAN/TILT/ZOOM/FOCUS Iris Shutter AGC Sens UP White BalancePatrol Play with a Controller not Having the Patrol Key Alarm Input/Output Alarm IN/OUTPatrol Play with a Controller Having the Patrol Key Patrol Play with the Auto PAN KeyCNT-CLS 1, 2 Output Cleaning CleaningElectronic Zoom EL-ZOOM Tilt Angle Tilt Angle 0 /5 Preset Alarm Preset ALMImage Hold Image Hold Camera Identification Camera ID Camera SettingTo Display the Camera Setting Menu ALC Mode with SUPER-D2 on Electronic Sensitivity Enhancement Sens UP Shutter Speed Setting ShutterGain Control AGC on LOW/ MID/ HIGH/OFF Line-lock Sync Mode LL Synchronization SyncWhite Balance White BAL Auto-Tracing White Balance Mode ATW1/ ATW2Automatic White Balance Control Mode AWC Motion Detector Motion DET Special 2 Menu SPECIAL2 Auto Focus Setting AF ModeResolution Resolution Auto S Auto M Auto L Manual L Manual M Manual SPIX Sens UP Setting Black and White Mode BW ModeBW Setting Burst BW SettingCamera Resetting Camera Reset PIX OFF Setting PIX OFFTo Restore the Camera Default Position Refresh To Close the SPECIAL2 MenuChanging the Camera Communication Parameters RS485 SetupInitial Camera Communication Parameters Preset Menu Preset ID ALC/MANUAL SUPER-D2 OFF Dwell Time Factory Default SettingMenu Setting CNT-CLS OFF Coax ALM OUTMounting the Camera InstallationPrecautions Ceiling mountMounting the Bracket PreparationsDisassembling the Camera Setting the Switches RS485 Parameter SetupSW1 For Panasonic’s ProtocolUnit Number Number SW2 RS485 SettingMounting the camera How to Assemble the Cable with the Accessory Connector AC Power Supply ConnectionAccessory Connector Information Connect this to 24V AC Class 2 Power SUP- PLY onlyRS485 Connection Alarm in ConnectionsAlarm OUT Connections OUTSystem Connections AGC On LOW/ON MID/ON HIGH/OFF SpecificationsPrevention of Blooming and Smear Accessories Optional AccessoriesAppendix ShortcutsVersion Française Pareil Accessoires Optionnels Mesures DE Précaution Construction ConfigurationAccessoires Préface Caractéristiques DominantesFonctionnement de la bascule numérique PréfaceCaractéristiques Dominantes Ne jamais essayer de démonter cette caméra vidéo Mesures DE PrécautionNettoyage de caméra vidéo Manipuler la caméra vidéo délicatementFonction dauto diagnostic Cette caméra vidéo ne doit pas être installée à l’envers13. Pièces de remplacement Mesure préventive contre lhyperluminosité et le traînageConstruction Configuration Menu de configurationRéglage de position p SW SET RemarquesDescription du menu de configuration Menu spécial Password LockVerrouillage de mot de passe Caméra vidéoVitesse d’obturation Shutter Commande d’éclairage ALC/MANUALMode ALC avec la fonction SUPER-D2 paramétrée sur OFF Contrôle automatique de gain AGCCommunication RS485 Procédure DE Réglage Affichage du menu de configurationSetup Menu Affichage de menuParamétrage de positionnement Menu de préréglageAffichage du menu de préréglage Position SETDécalage de balayage panoramique ZOOM/FOCUSComment effacer une identification préréglée sauvegardée Préréglage d’identification PresetComment saisir une nouvelle identification préréglée ALC/MANUAL Durée de temporisation Dwell TimeRéglage de contrôle de lumière Paramétrage de fichier de scèneSuppression des positions Préréglées Preset SpeedComment retourner au menu de Configuration Paramétrage de la vitesse prérégléeRetour automatique Sélection de mode automatiqueRéglage de position d’origine Position Réglage de retournement Numérique Digital Flip Vérification du mot de passe Nouveau mot de passeZone Paramétrage de menu spécial 1 SpecialZone de confidentialité Privacy Rapport zoom Titre de zone Area TitleZone Number Réglage par on NeswRéglage pour on User Édition de titre de zoneMémorisation de patrouille et lecture de patrouille Patrol Comment quitter l’éditionLecture de patrouille avec la touche Auto PAN Entrée-sortie dalarme AlarmIN/OUT CNT-CLS 1, 2 Sortie Nettoyage CleaningZoom électronique EL-ZOOM Angle dinclinaison Tilt Angle Préréglage d’alarme Preset ALMMaintien dimage Image Hold Camera ID Réglage de la caméra vidéoIdentification de caméra vidéo Mode ALC avec la fonction SUPER-D2 activée Mode ALC avec la fonction SUPER-D2 OFFContrôle automatique de gain Réglage de la vitesse d’obturationShutter AGC on LOW/MID/HIGH/OFFMode de synchronisation de fréquence trame et réseau LL Réglage de synchronisation SyncMode de contrôle automatique de balance des blancs AWC Balance des blancs White BALMotion Detect Détecteur de mouvementMotion DET Menu spécial 2 SPECIAL2 AF ModeRéglage de mise au point automatique Réduction de bruit numérique DNR Résolution ResolutionMode noir et blanc BW Mode Réglage BWComment fermer le menu SPECIAL2 Réglage Burst BWRéglage PIX OFF PIX OFF Configuration de RS485 Paramètres de communication initiaux De la caméra vidéoRéglages par défaut dusine Menu Rubrique RéglageVisière pare-soleil Installation de la caméra vidéoFixation au plafond Mesures de précautionDémontage de la caméra vidéo Installation de la platine de fixationPréparatifs Configuration de paramètre RS485 Positionnement des interrupteursCas du protocole de Panasonic Position de Numéro ’interrupteur ’unité 103 Installation de la caméra vidéo Réglage RS485Branchements Informations relatives aux connecteurs accessoiresComment assembler le câble au connecteur accessoire Connexion dalimentation à courant alternatif de 24Branchement RS485 Branchements AlarmBranchements Alarm OUT RemarqueBranchement DE Système Mesure Préventive Contre L’HYPERLUMINOSITÉ LE Traînage Caractéristiques TechniquesAccessoires Accessoires OptionnelsAnnexe Raccourcis111 N0803-0 3TR001811BAA