Panasonic WV-CW864A Factory Default Setting, Menu Setting, CNT-CLS OFF Coax ALM OUT

Page 44

Factory Default Setting

Menu

Item

Setting

TOP MENU

HOME POSITION

OFF

 

SELF RETURN

OFF

 

 

 

 

AUTO MODE

OFF

 

 

 

 

AUTO PAN KEY

AUTO PAN

 

DIGITAL FLIP

ON

 

PASSWORD LOCK

OFF

SPECIAL 1

PRIVACY ZONE

OFF

 

PROPO.P/T

ON

 

AREA TITLE

OFF

 

PATROL

STOP

 

 

 

 

CLEANING

OFF

 

 

 

 

EL-ZOOM

ON

 

PRESET ALM

OFF

 

IMAGE HOLD

OFF

 

TILT ANGLE

0 °

CAMERA MENU

CAMERA ID

OFF

 

ALC/MANUAL

ALC

 

SUPER-D2

OFF

 

 

 

 

SHUTTER

AUTO

 

 

 

 

AGC

ON (MID)

 

 

 

 

SENS UP

OFF

 

SYNC

INT

 

WHITE BAL

ATW1

 

MOTION DET

OFF

 

AF MODE

AUTO L

SPECIAL 2

CHROMA GAIN

• • • • I • • • •

 

AP GAIN

• • • • I • • • •

 

 

 

 

PEDESTAL

• • I • • • • • •

 

 

 

 

HUE

• • • • I • • • •

 

RESOLUTION

NORMAL

 

DNR

LOW2

 

BW

OFF

 

PIX SENS UP

OFF

 

BURST (BW)

ON

 

 

 

Menu

Item

Setting

PRESET MENU

PRESET ID

ON

 

ALC/MANUAL

ALC

 

SUPER-D2

OFF

 

 

 

 

DWELL TIME

10S

 

SCENE FILE

1

 

PRESET SPEED

• • • • • • • • I

SCENE FILE

SHUTTER

AUTO

 

AGC

ON (MID)

 

SENS UP

OFF

 

WHITE BAL

ATW1

 

 

 

 

MOTION DET

OFF

 

 

 

 

AF MODE

MANUAL L

AUTO PAN

SPEED

• • • • I • • • •

 

PAN LIMIT

OFF

 

ENDLESS

OFF

 

DWELL TIME

1S

RS485 SET UP

UNIT NUMBER

1

 

SUB ADDRESS

1

 

 

 

 

BAUD RATE

19200

 

 

 

 

DATA BIT

8

 

 

 

 

PARITY CHECK

NONE

 

STOP BIT

1

 

XON/XOFF

NOT USE

 

WAIT TIME

OFF

 

ALARM DATA

AUTO2

 

DELAY TIME

OFF

 

 

 

ALARM IN/OUT

ALARM IN1

OFF

 

ALARM IN2

OFF

 

 

 

 

ALARM IN3

OFF

 

ALARM IN4

OFF

 

CNT-CLS 1

OFF

 

TIME OUT

100ms

 

CNT-CLS 2

OFF

 

COAX ALM OUT

OFF

 

 

 

-44-

Image 44
Contents Color Cctv Camera English Version Important Safety Instructions EnglishPage Contents Digital Flip Operation FeaturesPreface Preset Data Uploading or Down Loading PrecautionsCamera Cleaning Do not install this camera upside down Do not install the camera in places subject to vibrationsConsumables Self-diagnosis FunctionConstruction Setup Setup MenuAUTO/ON/OFF P WV-CU550C/CJ WV-CU360C/CJWV-CU161C WV-RM70Setup Menu Description Camera Shutter Speed Shutter Gain Control AGCSynchronization Sync Important NoticesAuto Focus AF Mode RS485 Communication10Special 2 Menu SPECIAL2 11Self-diagnosis FunctionSetting Procedures Setup Menu DisplayMenu Display Submenu DisplayPreset Menu Preset Menu DisplayPosition Setting Position SET To Set Panning/Tilting PositionsPan Offset To Set the Lens Zoom and Focus PositionsPreset Identification Setting Preset ID Light Control Setting ALC/MANUAL Scene File Setting Scene FileTo Return to the Preset Setting Menu Dwell Time Dwell TimeDeleting Preset Positions Preset Speed Setting Preset SpeedTo Return to the Preset Number Set Menu To Return to the Setup MenuHome Position Setting Home Self Return Setting SelfAuto Mode Selection Auto OFF SEQ Sort Auto PAN PatrolZoom →PUSH SET RET SEQ Sort Patrol Auto Pan Key Setting Auto PAN KEYDigital Flip Setting Digital Flip New Password Password VerificationSpecial 1 Menu Setting Special Privacy Zone Privacy ZoneSettings for on Nesw Proportional Pan/Tilt PROPO. P/TArea Title Area Title Zoom ratioSetting for on User Area Title EditingPatrol-learn and Patrol Play Patrol To Quit EditingPatrol Learn with a Controller Having Patrol Key PAN/TILT/ZOOM/FOCUS Iris Shutter AGC Sens UP White BalanceAlarm Input/Output Alarm IN/OUT Patrol Play with a Controller Having the Patrol KeyPatrol Play with a Controller not Having the Patrol Key Patrol Play with the Auto PAN KeyCNT-CLS 1, 2 Output Cleaning CleaningElectronic Zoom EL-ZOOM Tilt Angle Tilt Angle 0 /5 Preset Alarm Preset ALMImage Hold Image Hold Camera Identification Camera ID Camera SettingTo Display the Camera Setting Menu ALC Mode with SUPER-D2 on Electronic Sensitivity Enhancement Sens UP Shutter Speed Setting ShutterGain Control AGC on LOW/ MID/ HIGH/OFF Line-lock Sync Mode LL Synchronization SyncWhite Balance White BAL Auto-Tracing White Balance Mode ATW1/ ATW2Automatic White Balance Control Mode AWC Motion Detector Motion DET Auto Focus Setting AF Mode Resolution ResolutionSpecial 2 Menu SPECIAL2 Auto S Auto M Auto L Manual L Manual M Manual S Black and White Mode BW Mode BW Setting PIX Sens UP Setting Burst BW SettingPIX OFF Setting PIX OFF To Restore the Camera Default Position RefreshCamera Resetting Camera Reset To Close the SPECIAL2 MenuChanging the Camera Communication Parameters RS485 SetupInitial Camera Communication Parameters Factory Default Setting Menu SettingPreset Menu Preset ID ALC/MANUAL SUPER-D2 OFF Dwell Time CNT-CLS OFF Coax ALM OUTInstallation PrecautionsMounting the Camera Ceiling mountMounting the Bracket PreparationsDisassembling the Camera Setting the Switches RS485 Parameter SetupSW1 For Panasonic’s ProtocolUnit Number Number SW2 RS485 SettingMounting the camera AC Power Supply Connection Accessory Connector InformationHow to Assemble the Cable with the Accessory Connector Connect this to 24V AC Class 2 Power SUP- PLY onlyAlarm in Connections Alarm OUT ConnectionsRS485 Connection OUTSystem Connections AGC On LOW/ON MID/ON HIGH/OFF SpecificationsPrevention of Blooming and Smear Accessories Optional AccessoriesAppendix ShortcutsVersion Française Pareil Mesures DE Précaution Construction Configuration AccessoiresAccessoires Optionnels Préface Caractéristiques DominantesFonctionnement de la bascule numérique PréfaceCaractéristiques Dominantes Mesures DE Précaution Nettoyage de caméra vidéoNe jamais essayer de démonter cette caméra vidéo Manipuler la caméra vidéo délicatementCette caméra vidéo ne doit pas être installée à l’envers 13. Pièces de remplacementFonction dauto diagnostic Mesure préventive contre lhyperluminosité et le traînageConstruction Configuration Menu de configurationRéglage de position p SW SET RemarquesDescription du menu de configuration Password Lock Verrouillage de mot de passeMenu spécial Caméra vidéoCommande d’éclairage ALC/MANUAL Mode ALC avec la fonction SUPER-D2 paramétrée sur OFFVitesse d’obturation Shutter Contrôle automatique de gain AGCCommunication RS485 Affichage du menu de configuration Setup MenuProcédure DE Réglage Affichage de menuMenu de préréglage Affichage du menu de préréglageParamétrage de positionnement Position SETDécalage de balayage panoramique ZOOM/FOCUSComment effacer une identification préréglée sauvegardée Préréglage d’identification PresetComment saisir une nouvelle identification préréglée Durée de temporisation Dwell Time Réglage de contrôle de lumièreALC/MANUAL Paramétrage de fichier de scènePreset Speed Comment retourner au menu de ConfigurationSuppression des positions Préréglées Paramétrage de la vitesse prérégléeRetour automatique Sélection de mode automatiqueRéglage de position d’origine Position Réglage de retournement Numérique Digital Flip Vérification du mot de passe Nouveau mot de passeZone Paramétrage de menu spécial 1 SpecialZone de confidentialité Privacy Titre de zone Area Title Zone NumberRapport zoom Réglage par on NeswRéglage pour on User Édition de titre de zoneMémorisation de patrouille et lecture de patrouille Patrol Comment quitter l’éditionLecture de patrouille avec la touche Auto PAN Entrée-sortie dalarme AlarmIN/OUT CNT-CLS 1, 2 Sortie Nettoyage CleaningZoom électronique EL-ZOOM Angle dinclinaison Tilt Angle Préréglage d’alarme Preset ALMMaintien dimage Image Hold Camera ID Réglage de la caméra vidéoIdentification de caméra vidéo Mode ALC avec la fonction SUPER-D2 activée Mode ALC avec la fonction SUPER-D2 OFFRéglage de la vitesse d’obturation ShutterContrôle automatique de gain AGC on LOW/MID/HIGH/OFFMode de synchronisation de fréquence trame et réseau LL Réglage de synchronisation SyncMode de contrôle automatique de balance des blancs AWC Balance des blancs White BALMotion Detect Détecteur de mouvementMotion DET Menu spécial 2 SPECIAL2 AF ModeRéglage de mise au point automatique Résolution Resolution Mode noir et blanc BW ModeRéduction de bruit numérique DNR Réglage BWComment fermer le menu SPECIAL2 Réglage Burst BWRéglage PIX OFF PIX OFF Configuration de RS485 Paramètres de communication initiaux De la caméra vidéoRéglages par défaut dusine Menu Rubrique RéglageInstallation de la caméra vidéo Fixation au plafondVisière pare-soleil Mesures de précautionDémontage de la caméra vidéo Installation de la platine de fixationPréparatifs Configuration de paramètre RS485 Positionnement des interrupteursCas du protocole de Panasonic Position de Numéro ’interrupteur ’unité 103 Installation de la caméra vidéo Réglage RS485Informations relatives aux connecteurs accessoires Comment assembler le câble au connecteur accessoireBranchements Connexion dalimentation à courant alternatif de 24Branchements Alarm Branchements Alarm OUTBranchement RS485 RemarqueBranchement DE Système Mesure Préventive Contre L’HYPERLUMINOSITÉ LE Traînage Caractéristiques TechniquesAccessoires Accessoires OptionnelsAnnexe Raccourcis111 N0803-0 3TR001811BAA