Controlling the Monitor with a PC (LAN)
Command-based control
You can control the monitor using
Read the manual for the terminal software for detailed instructions.
(1)Connect the PC to the monitor.
1.Specify the IP address and data port number (fixed at
“10008”), and connect the PC to the monitor.
When connection has been established successfully, [ Login:] is returned as response.
2.Enter the user name and password. (The default settings are blank.)
(2)Send commands to control the monitor.
•The commands used are the same as those for RS-
232C. Refer to the communication procedure (see page 32) for operation.
•Usable commands are provided in the
(3)Disconnect the connection with the monitor and quit the function.
1.Send [BYE ].
When the transmission is successful, [goodbye] is returned and the connection is disconnected.
TIPS
•The connection is automatically disconnected if there is no communication for about 5 minutes.