3M MT7 manual Reset Controller, Advanced Touch Options

Page 25

3M™ MicroTouch™ Software MT 7 User Guide

25

If after restoring controller factory defaults, you lose touch, you will need to reboot in order to restore touch.

Note: You must perform a calibration after restoring controller defaults.

Reset Controller

Use this only at the direction of Technical Support. This command initializes the hardware and the firmware, causes the controller to stop sending data, and recalculates the environmental conditions (for example, stray and offset values). The Reset command also cancels existing commands and returns the controller to normal operation.

Advanced Touch Options

Important Note: Executing the Advanced Options may alter the performance of your sensor or render it inoperable. You should be aware of expected results before executing any option. If you are not familiar with the outcome of these settings, you should not be using these options.

This option controls certain advanced functions for your controller. Depending on the options you have selected and the availability of that function for your given controller, you can choose certain Advanced Options from this screen.

Enable manual linearization (only for EX and some RX series controllers)

Enable pen/finger selection (only for SX controllers)

Enable frequency selection (only for EX capacitive controllers)

Enable controller identifier editing (helpful in multiple display setups)

Refer to the Controller Tab for a discussion of the various options associated with these Advanced Options settings.

3M Touch Systems, Inc. Proprietary Information – 25695M

Image 25
Contents 3M MicroTouch Software MT User Guide 3M MicroTouch Software MT 7 User Guide Contents Appendix a Multiple Monitor Setup Windows Only About This Manual Sensor Care and CleaningIntroduction Contact 3M Touch Systems 3M Touch Systems Support ServicesMT 7 Software Overview Installing MT 7 SoftwareTouch Drivers MT 7 Control PanelOnline Help MT 7 Windows Software Uninstall Utility Installing MT 7 SoftwareCalibration Tool Multiple Display ManagerDriver Selection User Interface Utilities and Tools Performing a Silent InstallUninstalling MT 7 Software Customizing Your SettingsOverview MT 7 Software Control PanelOpening the MT 7 Control Panel Calibration Main TabCalibrating the Sensor Support Information Testing the CalibrationController ID Firmware Version Controller TypeSensor Status Drawing Mode Default Value Touch Settings TabTouch Modes Liftoff Mode Touchdown ModeRight-Click Tool not available on Linux Touch SoundDouble-Click Speed not available on Windows CE or Linux Edge Adjustment TabDouble-Click Area not available on Windows CE or Linux Edge Adjustment Setting 3M MicroTouch Software MT 7 User Guide Component Versions Tools TabDraw Test Restore Factory SettingsSoftware ControllerAdvanced Touch Options Reset ControllerController Tab Linearization Process LinearizationPen and Finger Calibration Pen Overview Pen Controller OnlyPen Modes Testing the Newly Selected Frequency Sensor Frequency ProcedureSensor Frequency Controller ID Windows CE Overview Installation InstructionsLicense Agreement WelcomeSelect Installation Folder Installation Complete Confirm Installation3M MicroTouch Software MT 7 User Guide 3M MicroTouch Software MT 7 User Guide Slow Draw Anomalies Page Loading MT 7 Into The Components Database Manager Windows XP Embedded OverviewMT 7 Component Selection In Target Designer MT 7 Components System Requirements MT 7 for Linux OverviewHardware Prerequisites Software PrerequisitesGeneral Instructions Before Driver InstallationPreparation Installing on Write-Protected Systems Normal InstallationOther Options HotplugDir XinitDir and XinitSuffix Error Messages During InstallationCannot find needed libstdc++.so in /usr/lib Removing MT 7 For Linux Troubleshooting The Init ScriptRunning Touch Applications Troubleshooting Touch BehaviorCalibration Messages Are Unreadable Known IssuesPage Setting Up Multiple Monitors Multiple Monitor Setup Windows OnlyChanging the Controller ID 3M MicroTouch Software MT 7 User Guide 3M MicroTouch Software MT 7 User Guide Page Other Serial Devices Do Not Work Troubleshooting the Touch SystemCursor Does Not Reach Edges of Display Multiple Display SupportCursor is Jittery Cursor Jumps or Bounces Suddenly Across the DisplayFind Sensor for Serial Plug & Play Controllers Drawing Lines Are Not Straight and SmoothTouch Is Not Working Right-click Tool Buttons Are Swapped Touch Driver Did Not LoadPrevious Version of TouchWare Software Was Detected