3M™ MicroTouch™ Software MT 7 User Guide | 25 |
If after restoring controller factory defaults, you lose touch, you will need to reboot in order to restore touch.
Note: You must perform a calibration after restoring controller defaults.
Reset Controller
Use this only at the direction of Technical Support. This command initializes the hardware and the firmware, causes the controller to stop sending data, and recalculates the environmental conditions (for example, stray and offset values). The Reset command also cancels existing commands and returns the controller to normal operation.
Advanced Touch Options
Important Note: Executing the Advanced Options may alter the performance of your sensor or render it inoperable. You should be aware of expected results before executing any option. If you are not familiar with the outcome of these settings, you should not be using these options.
This option controls certain advanced functions for your controller. Depending on the options you have selected and the availability of that function for your given controller, you can choose certain Advanced Options from this screen.
∙Enable manual linearization (only for EX and some RX series controllers)
∙Enable pen/finger selection (only for SX controllers)
∙Enable frequency selection (only for EX capacitive controllers)
∙Enable controller identifier editing (helpful in multiple display setups)
Refer to the Controller Tab for a discussion of the various options associated with these Advanced Options settings.
3M Touch Systems, Inc. Proprietary Information – 25695M