3M MT7 manual Cannot find needed libstdc++.so in /usr/lib

Page 46

46

3M™ MicroTouch™ Software MT 7 User Guide

Cannot find needed libstdc++.so in /usr/lib

Variations of the message may refer to other directories depending on the setting of the LibDir variable in the Install script. The installation script could not find the standard C++ shared objects. Confirm that the LibDir variable is set correctly. If so, you need to install the C++ shared objects or, if already present, create a symbolic link using the name libstdc++.so to the C++ shared object. You also need to create a symbolic link named libstdc++.so.5 or libstdc++.so.6 depending on which version of library is on your system.

Cannot find shared memory support

The MT 7 for Linux® software uses shared memory. So me older Linux® systems do not provide this support and the package will not run. Contact 3M Touch Systems for other options.

Cannot find /etc/X11/xorg.conf

Variations of this error may occur if a system uses a different xorg.conf file.

MT 7 for Linux® uses an X input driver and requires this file so that the X server will load the driver. Since this file is optional, some systems do not have one present. If you use a different location for your xorg.conf file, edit the Install script and set the variable XorgConf. If is no xorg.conf file is present on the system there are two methods of creating one.

The first method is to create XorgConfig. To do this, go to single user mode. Run the command ‘X-configure.’ This produces the f ile ~/xorg.conf. Copy this file to /etc/X11/xorg.conf. Finish by restarting your system.

If the X Windows system restarts, you may proceed with the MT 7 installation. If X Windows does not start properly, get to a command prompt, it might be necessary to boot your system into single-user mode. Remove /etc/X11/xorg.conf and restart X Windows. If this happens you will need edit the xorg.conf file before placing it into /etc/X11/.

The second method is to edit the var-file. Copy the file /var/log/Xorg.0.log to another directory. Edit this file and look for a section where the X server says it is using a built-in configuration. Save just this section of the log file as a new xorg.conf file. Copy the new xorg.config file to /etc/X11/xorg.conf and restart X Windows. Proceed with the MT 7 installation.

3M Touch Systems, Inc. Proprietary Information – 25695M

Image 46
Contents 3M MicroTouch Software MT User Guide 3M MicroTouch Software MT 7 User Guide Contents Appendix a Multiple Monitor Setup Windows Only About This Manual Sensor Care and CleaningIntroduction 3M Touch Systems Support Services Contact 3M Touch SystemsTouch Drivers Installing MT 7 SoftwareMT 7 Software Overview MT 7 Control PanelCalibration Tool Installing MT 7 SoftwareOnline Help MT 7 Windows Software Uninstall Utility Multiple Display ManagerDriver Selection User Interface Performing a Silent Install Utilities and ToolsCustomizing Your Settings Uninstalling MT 7 SoftwareOverview MT 7 Software Control PanelOpening the MT 7 Control Panel Main Tab CalibrationCalibrating the Sensor Support Information Testing the CalibrationController ID Firmware Version Controller TypeSensor Status Drawing Mode Default Value Touch Settings TabTouch Modes Right-Click Tool not available on Linux Touchdown ModeLiftoff Mode Touch SoundDouble-Click Speed not available on Windows CE or Linux Edge Adjustment TabDouble-Click Area not available on Windows CE or Linux Edge Adjustment Setting 3M MicroTouch Software MT 7 User Guide Tools Tab Component VersionsSoftware Restore Factory SettingsDraw Test ControllerReset Controller Advanced Touch OptionsController Tab Linearization Linearization ProcessPen and Finger Calibration Pen Overview Pen Controller OnlyPen Modes Testing the Newly Selected Frequency Sensor Frequency ProcedureSensor Frequency Controller ID Installation Instructions Windows CE OverviewWelcome License AgreementSelect Installation Folder Confirm Installation Installation Complete3M MicroTouch Software MT 7 User Guide 3M MicroTouch Software MT 7 User Guide Slow Draw Anomalies Page Loading MT 7 Into The Components Database Manager Windows XP Embedded OverviewMT 7 Component Selection In Target Designer MT 7 Components Hardware Prerequisites MT 7 for Linux OverviewSystem Requirements Software PrerequisitesGeneral Instructions Before Driver InstallationPreparation Installing on Write-Protected Systems Normal InstallationOther Options HotplugDir Error Messages During Installation XinitDir and XinitSuffixCannot find needed libstdc++.so in /usr/lib Troubleshooting The Init Script Removing MT 7 For LinuxTroubleshooting Touch Behavior Running Touch ApplicationsKnown Issues Calibration Messages Are UnreadablePage Setting Up Multiple Monitors Multiple Monitor Setup Windows OnlyChanging the Controller ID 3M MicroTouch Software MT 7 User Guide 3M MicroTouch Software MT 7 User Guide Page Troubleshooting the Touch System Other Serial Devices Do Not WorkCursor is Jittery Multiple Display SupportCursor Does Not Reach Edges of Display Cursor Jumps or Bounces Suddenly Across the DisplayFind Sensor for Serial Plug & Play Controllers Drawing Lines Are Not Straight and SmoothTouch Is Not Working Touch Driver Did Not Load Right-click Tool Buttons Are SwappedPrevious Version of TouchWare Software Was Detected