3M MT7 manual Removing MT 7 For Linux, Troubleshooting The Init Script

Page 47

3M™ MicroTouch™ Software MT 7 User Guide

47

Cannot install the init script

The Install script tries to detect the presence of the chkconfig and update-rc.d utilities and the /etc/rc.d/rc.local script. If it cannot find any of these, this message appears. If your system uses the chkcconfig or update-rc programs, make sure the PATH environment variable contains the path to where the programs reside. If rc.local is in another directory, edit the Install script and change the value of the InitDir variable. If your system uses some other system, you need to place the init script TWDrvStartup in the appropriate place. The Install script creates a copy where the MT 7 for Linux® package resides. You may need to edit the TWDrvStartup script to work with your system.

Cannot install the X init script

The Install script could not determine where to install the X init script needed by MT 7 for Linux® to launch background tasks. Edit the Ins tall script and set the XinitDir variable.

Cannot install the X input module

The Install script could not find the directory for the X input module. Confirm that the variable XorgDir or XFree86Dir is set correctly in the Install script.

Hot plugging of USB touch controllers is not supported

The Install script cannot find the udev or hotplug support files. If you do not need hot plugging of USB controllers, ignore this message. Otherwise, edit the Install script and change the UdevDir or Hotplug variable to an appropriate value.

Removing MT 7 For Linux

In the installation directory, run the script Remove. This removes the data directories and disengages MT 7 for Linux® from the system. The fil es remain. You must manually remove the files from the twscreen directory.

Troubleshooting The Init Script

Due to the variety of methods of running init scripts, the Install script makes a best guess as to when the TWDrvStartup script should run. This guess is occasionally wrong.

There are three critical considerations regarding the init script sequence.

1.The USB file system must be operational before the TWDrvStartup script runs. If not, the driver does not service USB touch controllers. A symptom of this is calibration does not work.

2.Any script that inspects serial ports must finish before the TWDrvStartup script runs. These programs can interfere with the driver's ability to detect and identify serial touch controllers. A symptom of this is touch or calibration not working.

3M Touch Systems, Inc. Proprietary Information – 25695M

Image 47
Contents 3M MicroTouch Software MT User Guide 3M MicroTouch Software MT 7 User Guide Contents Appendix a Multiple Monitor Setup Windows Only Introduction Sensor Care and CleaningAbout This Manual Contact 3M Touch Systems 3M Touch Systems Support ServicesMT 7 Control Panel Installing MT 7 SoftwareMT 7 Software Overview Touch DriversMultiple Display Manager Installing MT 7 SoftwareOnline Help MT 7 Windows Software Uninstall Utility Calibration ToolDriver Selection User Interface Utilities and Tools Performing a Silent InstallUninstalling MT 7 Software Customizing Your SettingsOpening the MT 7 Control Panel MT 7 Software Control PanelOverview Calibration Main TabCalibrating the Sensor Controller ID Testing the CalibrationSupport Information Sensor Status Controller TypeFirmware Version Touch Modes Touch Settings TabDrawing Mode Default Value Touch Sound Touchdown ModeLiftoff Mode Right-Click Tool not available on LinuxDouble-Click Area not available on Windows CE or Linux Edge Adjustment TabDouble-Click Speed not available on Windows CE or Linux Edge Adjustment Setting 3M MicroTouch Software MT 7 User Guide Component Versions Tools TabController Restore Factory SettingsDraw Test SoftwareAdvanced Touch Options Reset ControllerController Tab Linearization Process LinearizationPen Modes Pen Overview Pen Controller OnlyPen and Finger Calibration Sensor Frequency Sensor Frequency ProcedureTesting the Newly Selected Frequency Controller ID Windows CE Overview Installation InstructionsLicense Agreement WelcomeSelect Installation Folder Installation Complete Confirm Installation3M MicroTouch Software MT 7 User Guide 3M MicroTouch Software MT 7 User Guide Slow Draw Anomalies Page MT 7 Component Selection In Target Designer Windows XP Embedded OverviewLoading MT 7 Into The Components Database Manager MT 7 Components Software Prerequisites MT 7 for Linux OverviewSystem Requirements Hardware PrerequisitesPreparation Before Driver InstallationGeneral Instructions Other Options Normal InstallationInstalling on Write-Protected Systems HotplugDir XinitDir and XinitSuffix Error Messages During InstallationCannot find needed libstdc++.so in /usr/lib Removing MT 7 For Linux Troubleshooting The Init ScriptRunning Touch Applications Troubleshooting Touch BehaviorCalibration Messages Are Unreadable Known IssuesPage Changing the Controller ID Multiple Monitor Setup Windows OnlySetting Up Multiple Monitors 3M MicroTouch Software MT 7 User Guide 3M MicroTouch Software MT 7 User Guide Page Other Serial Devices Do Not Work Troubleshooting the Touch SystemCursor Jumps or Bounces Suddenly Across the Display Multiple Display SupportCursor Does Not Reach Edges of Display Cursor is JitteryTouch Is Not Working Drawing Lines Are Not Straight and SmoothFind Sensor for Serial Plug & Play Controllers Right-click Tool Buttons Are Swapped Touch Driver Did Not LoadPrevious Version of TouchWare Software Was Detected