Bushnell SCOUT1000 manual If unit does not turn on LCD does not illuminate

Page 13

TROUBLE SHOOTING TABLE

If unit does not turn on - LCD does not illuminate:

Depress POWER button.

Check and if necessary, replace battery.

If unit powers down (display goes blank when attempting to power the laser):

The battery is either weak or low quality. Replace the battery with a good quality

3 -volt lithium battery.

If target range cannot be obtained:

Make sure LCD is illuminated.

Make sure that the power button is being depressed.

Make sure that nothing, such as your hand or finger, is blocking the objective lenses (lenses closest to the target) that emit and receive the laser pulses.

Make sure unit is held steady while depressing power button.

NOTE: The last range reading does not need to be cleared before ranging another target. Simply aim at the new target using the LCD’s reticle, depress the power button and hold until new range reading is displayed.

Specifications, instructions, and the operation of these products are subject to change without notice.

FCC Note

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Shielded interface cable must be used with the equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.

24

25

Image 13
Contents Scout 1000 Scout Power Eyepiece Mode Tripod Mount Ranging Accuracy HOW OUR Digital Technology WorksAdjusting the Eyepiece Getting Started Inserting the BatteryLiquid Crystal Display LCD Indicators Operational SummaryActive Laser Unit of Measure OptionsSelective Targeting Modes Page Tripod Mount Magnification and CoatingsPage Rifle Mode Example BOW Mode ExampleKnowing Which Ballistic Group to Select Regular ModeWhat if your caliber is not listed? ExampleCleaning SpecificationsIf target range cannot be obtained If unit does not turn on LCD does not illuminateScout 1000 Scout MARCHE/ARRÊT alimentation Oculaire Mode Monture de trépied Précision EN Distance Comment Notre Technologie FonctionneRéglage DE L’OCULAIRE Comment Démarrer Mise EN Place DE LA PileFonctionnement EN Bref Indicateurs DE L’AFFICHAGE À Cristaux Liquides LCDOptions D’UNITÉ DE Mesure Mode DE Visée SélectiveLaser Activé Page Monture DE Trépied Grossissement et traitementsNormal clignote au bas de l’écran Exemple DU Mode Fusil Exemple DU Mode TIR À L’ARCSavoir Quel Groupe Balistique Sélectionner Mode NormalEt si le calibre n’est pas sur la liste ? ExempleNettoyage CaractéristiquesSi la distance de la cible ne peut pas être obtenue Si l’appareil ne s’allume pas l’écran LCD ne s’active pasEspañol ON/OFF Encendido Ocular Modalidad Montura de trípode Exactitud DE LA Telemetría Cómo Funciona Nuestra Tecnología DigitalCómo Ajustar EL Ocular Instrucciones Iniciales Cómo Introducir LA PilaResumen Operacional Indicadores DE LA Pantalla DE Cristal Líquido LCDLáser Activo Opciones DE Unidad DE MedidaModalidades Selective Targeting Figura Adaptador DE Montaje EN Trípode Aumentos y recubrimientosUnidad DE Medida Ejemplo DE Modalidad Rifle Ejemplo DE Modalidad BOW ArcoCómo Saber QUÉ Grupo Balístico Seleccionar Modalidad Regular¿Qué hacer si su calibre no aparece en la lista? EjemploLimpieza EspecificacionesSi no se puede obtener la distancia al blanco Si la unidad no se enciende La pantalla LCD no se enciendeDeutsch AN/AUS Stromversorgung Ovular Modus Stativmontage Genauigkeit DER Entfernungsmessung Funktionsweise Unserer DigitaltechnologieEinstellen DES Okulars Inbetriebnahme Einsetzen DER BatterieZusammenfassung DER Funktionsweise LCD-ANZEIGEN Aktiver Laser MESSEINHEITS-OPTIONENSelektive Targeting Modi Page Stativmontage Vergrößerung und VergütungPage Beispiel GEWEHR-MODUS Beispiel BOGEN-MODUSDIE Wahl DER Richtigen Ballistischen Gruppe Normaler ModusIhr Kaliber ist nicht aufgeführt. Was nun? BeispielReinigung Technische DatenDie Zielentfernung lässt sich nicht feststellen 101102 104 106 105Descrizione Della Tecnologia Digitale Impiegata 108 Indicatori SUL Display a Cristalli Liquidi LCDPER Iniziare Inserimento Della Pila Regolazione DELL’OCULAREIndicazione DELL’UNITÀ DI Misura 110Laser Attivoi Modalità Selective Targeting112 114 113Ingrandimento e trattamento Sostegno PER TreppiedeAcceso ed il messaggio lampeggerà sul display, in basso 116117 Esempio DI Modo ArcoEsempio DI Modo Fucile 118120 Come Selezionare IL Gruppo Balistico Appropriato122 121Dati Tecnici 124Pulizia Se l’unità non si accende il LED non si illumina 126Se non si riesce a misurare la distanza dal bersaglio 127 129 Como Funciona Nossa Tecnologia Digital 131Como Começar Inserção DA Pilha 133Ajuste DA Ocular Resumo OperacionalOpções DA Unidade DE Medida 135Laser Ativo Modos Selective TargetingFigura 137139 138Ampliação e revestimentos Montagem EM Tripé141 Menu de Configuração Menu de operação normalExemplo do Modo Rifle Exemplo do Modo Arco143 145 Seleção do Grupo DE Balística Apropriado147 146Especificações 149Limpeza Unidade não liga o LCD não acende 151Se a leitura da distância do alvo não puder ser obtida