Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve,

Securely tighten all gas connections.

if connected to LP, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column,

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to de so can result in death, explosion, or fire.

Gas Type

Natural gas:

This dryer is equipped for use with Natural gas. It is design- certified by CSA International for LP (propane or butane) gases with appropriate conversion.

Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your local Sears store or Sears Service Center.

LP gas conversion:

Conversion must be made by a qualified technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different

gas without consulting your gas company.

Gas supply line

r/2" IPS pipe is recommended.

%" approved tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit.

Must include y8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer (see illustration).

Must include a shutoff valve:

An individual shutoff valve must be installed within 6 feet

(1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.

AC E

ililli

BD

A. %" flexible gas connector

B. _" pipe to flare adapter fitting

C. _" NPT minimum plugged tapping

D._2"NPT gas supply line E.Gas shutoff valve

Gas supply connection requirements

For close clearances, a %" to %" elbow is recommended to prevent kinking of the gas line.

Use only pipe-joint compound. Do not use TEFLON _t tape.

There are many methods by which your gas dryer can be connected to the gas supply. Listed here are some guidelines for two different methods of connection.

Option 1 (Recommended method)

Flexible stainless steel gas connector:

If local codes permit, use a new flexible stainless steel gas connector (Design Certified by CSA International) to connect your dryer to the rigid gas supply line. Use an elbow and a %" flare x %" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed to prevent kinking.

Option 2 (Alternate method)

Approved aluminum or copper tubing:

Lengths under 20 ft (6.1 m) can use %" approved tubing (if codes and gas supplier permit).

If you are using Natural gas, do not use copper tubing.

%" flare x %" NPT adapter fitting between dryer pipe and %" approved tubing.

Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting.

If your dryer has been converted to use LP gas, %" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger tubing.

NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON °t tape.

t®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

Image 8
Contents Gas Dryer Table of Contents Kenmore Appliance and Optional Pedestal WarrantyPedestal Product Record Dryer SafetyModel number Safety Instructions Pedestal Parts suppliedParts needed Stack KitInstallation clearances Custom undercounter installation Dryer onlyMinimum installation spacing for cabinet installation Mobile home additional installation requirementsMobile home installations require Grounding iNSTRUCTiONSGas supply connection requirements Gas supply lineOption 1 Recommended method Option 2 Alternate methodBurner input requirements Optional exhaust installations GoodBetterClamp Louvered hood style Box hood styleAlternate installations for close clearances Special provisions for mobile home installationsVent system chart Determine vent pathFor mobile home use Flared male fitting Non-flared male fittingRemove the door assembly Reverse hingePlug into a grounded 3 prong outlet If the dryer will not start, check the followingDryness Dryer USETo use an Auto Cycle To end/cancel your dryer at any time To use a Timed CycleTo pause/stop the dryer at any time Loading suggestionsCycle tips Dry most loads using the preset cycle settings Auto Cycles Preset Settings Wrin KLE Guard Dryer Care To clean dryer drum From Inside the Dryer CabinetFrom the Exhaust Vent Moving careTroubleshooting No heatUnusual sounds Dryer displaying code messageSears Installation Service Explosion HazardLint on load Is the lint screen clogged? Master Protection AgreementsSeguridad USO DE LA SecadoraCuidado SolucionGarantia Limitada DE UN Aiio Exclusion DE Garantias Implcitas Limitacion DE RecursosRegistro DEL Producto Registro DE Producto DEL PedestalSeguridad DE LA Secadora Su seguridad y la seguridad de los demas es muy importanteADVERTENClA Pedestal Piezas suministradasPatas niveladoras Piezas para adquirirInstalacibn en el cl6set S61o secadora Dimensiones de la secadoraEspacios para la Instalacibn Espacio minimo para la instalacibn en un armario Las instalaciones en casas rodantes necesitanPeligro de Choque Elctrico Peligro de E×plosi6nTipo de gas Gas natural La conversi6n debera Ilevarla a cabo un tcnico calificadoRequisitos para la conexibn del suministro de gas Opcibn 1 Mtodo recomendadoOpcibn 2 Mtodo alternativo Elevaciones encima de los 10.000 pies 3.048 metrosSi este es un nuevo sistema de ventilacibn Material de ventilacibnIlamar al 1-800-4-MY-HOME Ducto de escape de metal flexiblePieza nQmero26-49901 Desacoplo de menos de 5 12,7 cm Instalaciones opcionales de escapePeligro de Incendio Instalaciones alternas para espacios limitadosCuadro del sistema de ventilaci6n No. de Tipo de Capotas deMetal Metal RigidoPara su uso en casas rodantes Accesorios macho abocinados Accesorios macho no abocinadosC6mo quitar el ensamblaje de la puerta Invierta la bisagraVuelva a instalar la puerta Si la secadora no funciona, revise Io siguienteUsa DE LA Secadora Para usar un ciclo de secado automtico£ t ¢i,*S Dryness LevelPara usar un ciclo programado De capacidad Superior Ropa de trabajo pesadaOcos s£om4t£cos Ropa delicada Delicate Ajustes prefijados de ciclos automaticosAjustes prefijados de ciclos programados TouchCuando use s61o aire Protector antiarrugas Wrin KLE Guard eSerial de ciclo Cambio de ciclos despus de presionar puesta en marcha@OJ£Ie ImportanteSolucion DE Problemas Cuidado para las vacacionesIXOYt,, I?q1,f@,,,/ii,¢ Sin calorLa secadora muestra mensajes codificados El tiempo del ciclo es demasiado cortoEsta el filtro de pelusa obstruido con pelusa? Esta la secadora ubicada en un armario?Proteccion Pelusa en la ropa Esta obstruido el filtro de pelusa?Contratos Maestros de Proteccibn Revisibn Anual de Mantenimiento Preventivo a solicitudSea rs